Skip to product information
1 of 3

HIMatrix F2 DO 16 01 HIMA Safety-Related Controller

HIMatrix F2 DO 16 01 HIMA Safety-Related Controller

  • Manufacturer: HIMA

  • Product No.: F2 DO 16 01

  • Condition:1000 in stock

  • Product Type: Safety-Related Controller

  • Product Origin: Germany

  • Payment: T/T, Western Union

  • Weight: 900g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Details
Manufacturer: HIMA
Model/Part Number: HIMatrix F2 DO 16 01
Description: Safety-Related Controller

Product Data

General
Response time ≥ 20 ms
Ethernet interfaces 2 x RJ-45, 10BASE-T/100BASE-Tx with integrated switch
Operating voltage 24 VDC, -15...+20 %, rPP ≤ 15 %, from a power supply unit with safe insulation (IEC 61131-2)
Current input Max. 9 A per group
Idle current Approx. 0.2 A per group at 24 V
Fuse (external) 10 A time-lag (T)
Back-up battery None
Operating temperature 0...+60 °C
Storage temperature -40...+85 °C
Protection type IP20
Dimensions (without plug) Width: 207 mm (with housing screws), Height: 114 mm (with fixing bolt), Depth: 66 mm (with earthing screw)
Weight Approx. 0.9 kg

Digital Outputs

  • Number of outputs: 16 (non-galvanically separated)
  • Output voltage: ≥ L+ minus 2 V
  • Output current:
    • Max. 2 A at < 40 °C
    • Max. 1 A at 40…60 °C
  • Current per group:
    • Total permissible current: Max. 8 A
    • Max. 16 A for all groups combined
  • Minimum load: 2 mA for each channel
  • Lamp load:
    • Max. 10 W (with output 1 A)
    • Max. 25 W (with output 2 A)
  • Inductive load: Max. 500 mH
  • Internal voltage drop: Max. 2 V at 2 A
  • Leakage current (with low level): Max. 1 mA at 2 V
  • Behavior upon overload: The affected output is switched off and cyclically switched on again

 

 Check below popular items for more information in  Industrial Control Hub
Brand Description Price(USD) Stock Link
HIMA M2215 PLC Module 0–571 690 M2215 PLC Module
HIMA RS485-PCI RS485 Interface Card PCI 0–643 230 RS485-PCI Interface Card
HIMA F30 03 Safety-Related Controller 1786–2786 430 F30 03 Safety-Related Controller
HIMA F2DO401 Safety-Related Controller 214–1214 840 F2DO401 Safety-Related Controller
HIMA PS 1000 WR 011 Power Supply 643–1643 860 PS 1000 WR 011 Power Supply
HIMA 32100 Relay Module 307–1307 260 32100 Relay Module
HIMA F2DO8 01 Safety-Related Controller 929–1929 420 F2DO8 01 Safety-Related Controller
HIMA F60 AI 801 Safety-Related Controller 1643–2643 790 F60 AI 801 Safety-Related Controller
View full details

Product Description

Product Details
Manufacturer: HIMA
Model/Part Number: HIMatrix F2 DO 16 01
Description: Safety-Related Controller

Product Data

General
Response time ≥ 20 ms
Ethernet interfaces 2 x RJ-45, 10BASE-T/100BASE-Tx with integrated switch
Operating voltage 24 VDC, -15...+20 %, rPP ≤ 15 %, from a power supply unit with safe insulation (IEC 61131-2)
Current input Max. 9 A per group
Idle current Approx. 0.2 A per group at 24 V
Fuse (external) 10 A time-lag (T)
Back-up battery None
Operating temperature 0...+60 °C
Storage temperature -40...+85 °C
Protection type IP20
Dimensions (without plug) Width: 207 mm (with housing screws), Height: 114 mm (with fixing bolt), Depth: 66 mm (with earthing screw)
Weight Approx. 0.9 kg

Digital Outputs

  • Number of outputs: 16 (non-galvanically separated)
  • Output voltage: ≥ L+ minus 2 V
  • Output current:
    • Max. 2 A at < 40 °C
    • Max. 1 A at 40…60 °C
  • Current per group:
    • Total permissible current: Max. 8 A
    • Max. 16 A for all groups combined
  • Minimum load: 2 mA for each channel
  • Lamp load:
    • Max. 10 W (with output 1 A)
    • Max. 25 W (with output 2 A)
  • Inductive load: Max. 500 mH
  • Internal voltage drop: Max. 2 V at 2 A
  • Leakage current (with low level): Max. 1 mA at 2 V
  • Behavior upon overload: The affected output is switched off and cyclically switched on again

 

 Check below popular items for more information in  Industrial Control Hub
Brand Description Price(USD) Stock Link
HIMA M2215 PLC Module 0–571 690 M2215 PLC Module
HIMA RS485-PCI RS485 Interface Card PCI 0–643 230 RS485-PCI Interface Card
HIMA F30 03 Safety-Related Controller 1786–2786 430 F30 03 Safety-Related Controller
HIMA F2DO401 Safety-Related Controller 214–1214 840 F2DO401 Safety-Related Controller
HIMA PS 1000 WR 011 Power Supply 643–1643 860 PS 1000 WR 011 Power Supply
HIMA 32100 Relay Module 307–1307 260 32100 Relay Module
HIMA F2DO8 01 Safety-Related Controller 929–1929 420 F2DO8 01 Safety-Related Controller
HIMA F60 AI 801 Safety-Related Controller 1643–2643 790 F60 AI 801 Safety-Related Controller

Download PDF file here: