Product Description
ABB A210-30-11-80 Contactor
Overview
The ABB A210-30-11-80 is a 3-phase contactor designed for a variety of applications, such as motor starting, isolation, bypass, and distribution. It operates with a control voltage in the range of 220-230 V AC (50 Hz) or 230-240 V AC (60 Hz), and is suitable for applications up to 690 V. This contactor is capable of handling high currents and voltages, and is commonly used in industrial and commercial applications.
Key Features
-
Rated Operational Voltage: 690 V (Main Circuit)
-
Number of Poles: 3P (3 Phase)
-
Number of Main Contacts NO: 3
-
Number of Auxiliary Contacts NO: 1
-
Rated Current: Up to 350 A (depending on temperature and configuration)
-
Short-Circuit Protective Devices: gG Type Fuses (400 A)
-
Mechanical Durability: 5 million cycles
-
Electrical Durability: 300 cycles per hour (AC-1)
Technical Specifications
Parameter |
Details |
Rated Control Circuit Voltage (Uc) |
220-230 V (50 Hz) / 230-240 V (60 Hz) |
Rated Operational Voltage (Main Circuit) |
690 V (max) |
Rated Operational Current (AC-1) |
Up to 350 A (depending on temperature) |
Rated Operational Current (AC-3) |
210 A (for various voltages: 380V, 440V, 500V, 690V) |
Rated Power (AC-3) |
110 kW (415V), 160 kW (690V) |
Rated Short-Circuit Withstand Current |
1700 A (10s), 1000 A (1min), 2500 A (1s) |
Rated Impulse Withstand Voltage (Uimp) |
8 kV (Main Circuit) |
Mechanical Durability |
5 million cycles |
Maximum Electrical Switching Frequency |
300 cycles/hour (AC-1), 150 cycles/hour (AC-2/AC-4) |
Coil Consumption |
Holding: 60 V·A (50 Hz), 65 V·A (60 Hz); Pull-in: 1350 V·A (50 Hz) |
Operate Time |
7-13 ms (NC Contact Closing), 10-16 ms (NO Contact Opening) |
Degree of Protection |
Coil Terminals IP20, Main Terminals IP00 |
Dimensions
Parameter |
Value |
Width |
140 mm |
Depth / Length |
180.5 mm |
Height |
227 mm |
Net Weight |
5.4 kg |
Electrical and Mechanical Ratings
-
Rated Breaking Capacity AC-3: 8x Ie
-
Rated Making Capacity AC-3: 10x Ie
-
Mechanical Switching Frequency: Up to 3600 cycles/hour
-
Rated Control Circuit Voltage: 220-240 V AC (50/60 Hz)
-
Maximum Operating Voltage (UL/CSA): 600 V
Environmental Specifications
-
Ambient Temperature:
- Operation (with Thermal O/L Relay): -25 °C to +50 °C
- Operation (without Thermal O/L Relay): -40 °C to +70 °C
- Storage: -40 °C to +70 °C
-
Maximum Operating Altitude: 3000 m (without derating)
Certifications and Approvals
-
CE Certification: CE Declaration of Conformity for A210 series contactors.
-
UL/CSA Certification: 300 A General Use Rating, suitable for use in various industrial applications.
-
Additional Certifications: BV, CQC, DNV, GL, and several others.
Packaging
-
Package Units: 1 piece per box
-
Package Dimensions:
- Width: 203 mm
- Depth/Length: 245 mm
- Height: 188 mm
-
Package Gross Weight: 6.1 kg
-
EAN Code: 7320500203323
Application
The A210-30-11-80 contactor is used for switching high-power electrical loads in industrial and commercial settings, including:
-
Motor Control: Direct-on-line (DOL) or for use with motor protection relays.
-
Isolation and Switching: In distribution boards and motor control centers.
-
Bypass Applications: For enabling and disabling motor systems.