Product Details: Bently Nevada 9200-02-05-10-00 Two-wire Seismoprobe Transducer


General Information

  • Manufacturer: Bently Nevada
  • Model/Part Number: 9200-02-05-10-00
  • Description:
    • A two-wire transducer designed for seismic vibration measurement.
    • It features high accuracy and durability with an optional fluid-resistant cable.
    • Provides output related to the vibration of the machine or casing, which can be used with 3300 or 3500 monitors.

Specifications

Parameter Details
Electrical Sensitivity 20 mV/mm/s (500 mV/in/s), ±5% when properly terminated and oriented at the angle of calibration
Calibration Load 10 kΩ Terminal "A" to "B" Output
Sensitivity Temperature Coefficient 0.2%/°C
Frequency Response 4.5 to 1000 Hz (270 to 60,000 CPM), +0, -3dB typical
Dynamic Operating Range 2.54 mm (0.100 in) peak to peak maximum displacement
Velocity Range 25 mm/s (1 in/s) at +22°C with a 10 kΩ load
Coil Resistance 1.25 kΩ ±5%
Locked Coil Inductance 125 mH, typical
Amplitude Linearity ±5% from 0.01 to 5.0 in/s (0.254 to 127 mm/s) at 100Hz (6000 CPM)
Shock Resistance Withstands 50 g peak maximum acceleration along non-sensitive axis
Transverse Sensitivity ±10% maximum of sensitive axis sensitivity at 100 Hz and 1.0 in/s (2.54 cm/s)
Polarity of Output Signal Pin A goes positive with respect to Pin B when transducer case velocity is towards the connector
Lead Wire Length 305 meters (1,000 feet) maximum, consult manual for frequency roll-off at longer lengths

Environmental Limits

Parameter Operating Temperature Storage Temperature
9200 Series -29°C to +121°C (-20°F to +250°F) -29°C to +121°C (-20°F to +250°F)
74712 Series (Alternative) -29°C to +204°C (-20°F to +400°F) -29°C to +204°C (-20°F to +400°F)
Humidity 95% relative humidity, non-condensing.
100% non-submerged with integral cable option

Mounting and Connector Options

  • A: Transducer Mounting Angle/Minimum Operating Frequency Option

    • 01: 0 ±2.5°, 4.5 Hz (270 cpm)
    • 02: 45 ±2.5°, 4.5 Hz (270 cpm)
    • 03: 90 ±2.5°, 4.5 Hz (270 cpm)
    • 06: 0 ±100°, 10 Hz (600 cpm)
    • 09: 0 ±180°, 15 Hz (900 cpm)
  • B: Connector/Cable Option

    • 01: Top Mount (no cable)
    • 02: Side Mount (no cable)
    • 05: Terminal block top mount (no cable)
    • 10-50: Integral hardline cable options (7 to 50 feet)
  • C: Mounting Base Option

    • 01: Circular, 1/4-20 UNC stud
    • 02: Circular, 1/4-28 UNF stud
    • 03: Rectangular flange
    • 04: Circular, with three 8-32 threaded studs (44 mm bolt circle)
    • Multiple isolated base and stud configurations available.
  • D: Agency Approval Option

    • 00: No Approvals
    • 01: CSA
    • 04: ATEX/IECEx

Physical Dimensions and Weight

Parameter Details
Height 102 mm (4 in) typical
Diameter 41 mm (1.6 in) typical
Weight 9200 = 300 g (10.5 oz) typical, 74712 = 480 g (17 oz) typical

Notes

  • For optimal performance, the mounting angle and minimum operating frequency should match your specific application needs.
  • Ensure proper cable selection based on environmental conditions, especially when operating in hazardous or extreme environments.
  • The output signal polarity depends on the transducer case velocity direction relative to the connector.

 

Check below popular items for more information in  Industrial Control Hub
Brand Description  Price (USD)  Stock Link
Bently Nevada 330101-00-52-10-02-05 3300 XL 8 mm Proximity Probe 88-1088 200 3300 XL 8 mm Proximity Probe
Bently Nevada 3500/65 16-Channel Temperature Monitor (145988-02)  3702-4702  700 16-Channel Temperature Monitor
Bently Nevada 3300/20 Dual Thrust Position Monitor (12-01-13) 1171-2171 200 Dual Thrust Position Monitor
Bently Nevada 3300/05 Rack (24-00-00)  241-1241  200 Rack
Bently Nevada 3500/50 Tachometer Module (01-00, 288062-02 + 133442-01)  2100-3100  500 Tachometer Module
View full details

Product Description

Product Details: Bently Nevada 9200-02-05-10-00 Two-wire Seismoprobe Transducer


General Information

  • Manufacturer: Bently Nevada
  • Model/Part Number: 9200-02-05-10-00
  • Description:
    • A two-wire transducer designed for seismic vibration measurement.
    • It features high accuracy and durability with an optional fluid-resistant cable.
    • Provides output related to the vibration of the machine or casing, which can be used with 3300 or 3500 monitors.

Specifications

Parameter Details
Electrical Sensitivity 20 mV/mm/s (500 mV/in/s), ±5% when properly terminated and oriented at the angle of calibration
Calibration Load 10 kΩ Terminal "A" to "B" Output
Sensitivity Temperature Coefficient 0.2%/°C
Frequency Response 4.5 to 1000 Hz (270 to 60,000 CPM), +0, -3dB typical
Dynamic Operating Range 2.54 mm (0.100 in) peak to peak maximum displacement
Velocity Range 25 mm/s (1 in/s) at +22°C with a 10 kΩ load
Coil Resistance 1.25 kΩ ±5%
Locked Coil Inductance 125 mH, typical
Amplitude Linearity ±5% from 0.01 to 5.0 in/s (0.254 to 127 mm/s) at 100Hz (6000 CPM)
Shock Resistance Withstands 50 g peak maximum acceleration along non-sensitive axis
Transverse Sensitivity ±10% maximum of sensitive axis sensitivity at 100 Hz and 1.0 in/s (2.54 cm/s)
Polarity of Output Signal Pin A goes positive with respect to Pin B when transducer case velocity is towards the connector
Lead Wire Length 305 meters (1,000 feet) maximum, consult manual for frequency roll-off at longer lengths

Environmental Limits

Parameter Operating Temperature Storage Temperature
9200 Series -29°C to +121°C (-20°F to +250°F) -29°C to +121°C (-20°F to +250°F)
74712 Series (Alternative) -29°C to +204°C (-20°F to +400°F) -29°C to +204°C (-20°F to +400°F)
Humidity 95% relative humidity, non-condensing.
100% non-submerged with integral cable option

Mounting and Connector Options

  • A: Transducer Mounting Angle/Minimum Operating Frequency Option

    • 01: 0 ±2.5°, 4.5 Hz (270 cpm)
    • 02: 45 ±2.5°, 4.5 Hz (270 cpm)
    • 03: 90 ±2.5°, 4.5 Hz (270 cpm)
    • 06: 0 ±100°, 10 Hz (600 cpm)
    • 09: 0 ±180°, 15 Hz (900 cpm)
  • B: Connector/Cable Option

    • 01: Top Mount (no cable)
    • 02: Side Mount (no cable)
    • 05: Terminal block top mount (no cable)
    • 10-50: Integral hardline cable options (7 to 50 feet)
  • C: Mounting Base Option

    • 01: Circular, 1/4-20 UNC stud
    • 02: Circular, 1/4-28 UNF stud
    • 03: Rectangular flange
    • 04: Circular, with three 8-32 threaded studs (44 mm bolt circle)
    • Multiple isolated base and stud configurations available.
  • D: Agency Approval Option

    • 00: No Approvals
    • 01: CSA
    • 04: ATEX/IECEx

Physical Dimensions and Weight

Parameter Details
Height 102 mm (4 in) typical
Diameter 41 mm (1.6 in) typical
Weight 9200 = 300 g (10.5 oz) typical, 74712 = 480 g (17 oz) typical

Notes

  • For optimal performance, the mounting angle and minimum operating frequency should match your specific application needs.
  • Ensure proper cable selection based on environmental conditions, especially when operating in hazardous or extreme environments.
  • The output signal polarity depends on the transducer case velocity direction relative to the connector.

 

Check below popular items for more information in  Industrial Control Hub
Brand Description  Price (USD)  Stock Link
Bently Nevada 330101-00-52-10-02-05 3300 XL 8 mm Proximity Probe 88-1088 200 3300 XL 8 mm Proximity Probe
Bently Nevada 3500/65 16-Channel Temperature Monitor (145988-02)  3702-4702  700 16-Channel Temperature Monitor
Bently Nevada 3300/20 Dual Thrust Position Monitor (12-01-13) 1171-2171 200 Dual Thrust Position Monitor
Bently Nevada 3300/05 Rack (24-00-00)  241-1241  200 Rack
Bently Nevada 3500/50 Tachometer Module (01-00, 288062-02 + 133442-01)  2100-3100  500 Tachometer Module

Download PDF file here:

Click to Download PDF