Product Description
General Information
|
Manufacturer |
Bently Nevada |
|---|---|
|
Model/Part Number |
21000-16-10-15-054-03-02 |
|
Model Type |
Proximity Probe Housing Assemblies |
_
Description
The_Proximity Probe Housing Assemblies_are used to externally mount proximity probes. These all-metal housings come in two types:
__21000 Aluminum Probe Housing Assembly
__24701 Stainless Steel Probe Housing Assembly
_
Specifications
Environmental Limits
|
Probe Type |
Operating Temperature |
Storage Temperature |
|---|---|---|
|
3300 XL 8mm Probe |
-51°C to +177°C (-60°F to +351°F) |
-51°C to +177°C (-60°F to +351°F) |
|
3300 XL 11mm Probe |
-51°C to +177°C (-60°F to +351°F) |
-51°C to +177°C (-60°F to +351°F) |
|
3300 NSv Probe |
-34°C to +177°C (-30°F to +351°F) |
-51°C to +177°C (-60°F to +351°F) |
Mechanical Specifications
|
Property |
Specification |
|---|---|
|
Material |
21000 Aluminum body with 304 stainless steel sleeve |
|
Mass (Weight) |
1.1 kg (2.4 lb) typical, without fittings |
_
Ordering Information
Proximity Probe Housing Assemblies:_21000-AA-BB-CC-DDD-EE-FF
A: Probe with Connector
|
Code |
Description |
|---|---|
|
00 |
Probe not required |
|
14 |
420 nuclear |
|
16 |
3300 XL 8mm probe |
|
26 |
3300 XL NSv probe |
|
27 |
3300 XL NSv probe, selectable hazardous area approvals |
|
28 |
3300 XL 8mm probe, selectable hazardous area approvals |
|
29 |
3300 XL 11mm probe |
|
30 |
3300 XL 11mm probe, selectable hazardous area approvals |
|
31 |
3300 XL NSv probe with connector protector |
|
32 |
3300 XL NSv probe with connector protector, selectable hazardous area approvals |
|
33 |
3300 XL 8mm probe with connector protector |
|
34 |
3300 XL 8mm probe with connector protector, selectable hazardous area approvals |
|
35 |
3300 XL 11mm probe with connector protector |
|
36 |
3300 XL 11mm probe with connector protector, selectable hazardous area approvals |
|
37 |
3300 XL 8mm probe, ETR, selectable hazardous area approvals (available for 21000 only) |
B: Probe Cable Length
|
Code |
Length |
|---|---|
|
00 |
Probe cable not required |
|
05 |
0.5 m (20 in) |
|
10 |
1.0 m (39 in) |
|
12 |
12.0 in |
|
18 |
18.0 in |
|
24 |
24.0 in |
|
30 |
30.0 in |
|
36 |
36.0 in |
C: Standoff Adapter (Option C Dimension)
|
Code |
Length |
|---|---|
|
15 |
Minimum length 1.5 in (38 mm) |
|
75 |
Maximum length 7.5 in (191 mm) |
|
Recommendation |
Order in increments of 0.5 in (13 mm) |
D: Probe Penetration (Option D Dimension)
|
Code |
Length |
|---|---|
|
10 |
Minimum length 1.0 in (25.4 mm) |
|
Recommendation |
Order in increments of 0.1 in (3 mm) |
E: Fittings
|
Code |
Description |
|---|---|
|
00 |
Without fittings |
|
01 |
One 3/4-14 NPT explosion-proof fitting, one 3/4-14 NPT plug |
|
02 |
Two 3/4-14 NPT explosion-proof fittings |
|
03 |
One 3/4-14 NPT plug, one 3/4-14 to 1/2-14 NPT reducer, one cable seal grip with grommets for cable sizes: 1/8 to 3/16 in, 1/4 to 5/16 in, 5/16 to 3/8 in |
|
04 |
One 3/4-14 NPT plug only |
Note:_Explosion-proof fittings are available for all housings, but only_CA versions_of the housing are_rated explosion-proof_by_CSA_when ordered with the_E:00, E:01, E:02, or E:04 options.
F: Mounting Thread
|
Code |
Description |
|---|---|
|
01 |
As cast without threads |
|
02 |
3/4-14 NPT (Must be ordered if Standoff Adapter Length option is not 00) |
|
04 |
1/2-14 BSP |
_
| Check below popular items for more information in_ | Industrial Control Hub | |||
| Brand | Description | _Price (USD)_ | Stock | Link |
| Bently Nevada | 16710-12 Interconnect Cables | _0-884_ | 300 | Interconnect Cables |
| Bently Nevada | 3500/50M I/O Module with Internal Terminations (133442-01) | _0-871_ | 400 | I/O Module with Internal Terminations |
| Bently Nevada | 16710-20 Interconnect Cables | _0-862_ | 500 | Interconnect Cables |
| Bently Nevada | 130539-30 Interconnect Cable | _0-854_ | 600 | Interconnect Cable |
| Bently Nevada | 16710-25 Interconnect Cable | _0-846_ | 700 | Interconnect Cable |
| Bently Nevada | 16710-10 Interconnect Cables | _0-846_ | 200 | Interconnect Cables |