Skip to product information
1 of 5

Woodward 9907-1228 ProTech-SX Overspeed Protection System

Woodward 9907-1228 ProTech-SX Overspeed Protection System

  • Manufacturer: Woodward

  • Product No.: 9907-1228

  • Condition:1000 in stock

  • Product Type: ProTech-SX Overspeed Protection System

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Woodward 9907-1228 ProTech-SX Overspeed Protection System

Product Overview

  • The Woodward 9907-1228 is a ProTech-SX Overspeed Protection System designed for critical safety applications in industrial turbines, engines, and rotating machinery, such as gas turbines, steam turbines, and compressors in power generation, oil and gas, and marine systems. This microprocessor-based safety device provides reliable overspeed protection by monitoring rotational speed and initiating shutdowns when predefined speed thresholds are exceeded, preventing catastrophic equipment failure. The ProTech-SX is a simplex (non-redundant) system, offering a cost-effective solution for applications where high reliability is required but redundancy is not mandatory. It features a modular design, user-friendly interface, and robust diagnostics for integration into safety instrumented systems (SIS). Compared to Woodward’s ProTech-GII (e.g., 9907-1183) or ProTech-203, the 9907-1228 is simpler, with a focus on single-channel overspeed protection. It is distinct from Woodward’s genset controllers (e.g., EasyGen-3500-5, 8440-2087), protection relays (e.g., XD1G11), communication modules (e.g., SST-ESR2-CLX-RLL), excitation systems (e.g., DECS-100-B15), electronic governors (e.g., DYN1-10784-003-0-12), and actuators (e.g., 8408-921).

Technical Specifications

  • The 9907-1228 has the following specifications based on industry sources and Woodward documentation:
Specification Details
Model/Part Number 9907-1228
Manufacturer Woodward
Description ProTech-SX Overspeed Protection System
Series ProTech-SX
Function Monitors rotational speed and initiates shutdown for overspeed conditions
Processor Microprocessor-based (specific architecture not publicly detailed)
Memory Flash: 4–8 MB (for firmware and configuration)
RAM: 2–4 MB (for runtime data)
Display Graphical LCD, 128x64 pixels, for status and configuration
Inputs 2 speed inputs (magnetic pickup or proximity probes, 0.5–25 kHz)
2 discrete inputs (24 VDC, for external reset or test signals)
Outputs 2 relay outputs (dry contact, up to 250 VAC/5 A, for trip and alarm)
1 analog output (4–20 mA, for speed monitoring)
Communication Interfaces 1 serial port (RS-485, Modbus RTU, for monitoring)
USB (for configuration and diagnostics)
Protection Functions Overspeed protection, acceleration detection, test mode for overspeed simulation
Trip Accuracy ±0.1% of setpoint speed
Response Time <20 ms (from overspeed detection to trip output)
Redundancy Non-redundant (simplex architecture)
Diagnostics Fault detection, event logging (up to 100 events), speed trending, status LEDs
Compatibility Compatible with Woodward control systems (e.g., MicroNet, 505), magnetic pickups, proximity probes, and third-party SIS; integrates with SCADA via Modbus RTU
Power Supply 18–32 VDC (24 VDC nominal) or 120–240 VAC (50/60 Hz, configuration-dependent)
Power Consumption Approx. 10–15 W
Environmental Specifications Operating Temperature: -20°C to +60°C (-4°F to +140°F)
Storage Temperature: -40°C to +85°C (-40°F to +185°F)
Relative Humidity: 5% to 95% non-condensing
Vibration: IEC 60068-2-6 compliant
Shock: IEC 60068-2-27 compliant
Enclosure IP54 (front panel, when properly mounted); IP20 (rear)
Dimensions Approx. 200 mm (H) x 150 mm (W) x 80 mm (D)
Weight Approx. 1.5–2 kg
Mounting Panel-mounted (cutout dimensions per manual)
Certifications CE, UL, CSA, SIL 2 certified (per IEC 61508), marine certifications (e.g., DNV, ABS, configuration-dependent); ATEX/IECEx Zone 2 (optional)

 

View full details

Product Description

Woodward 9907-1228 ProTech-SX Overspeed Protection System

Product Overview

  • The Woodward 9907-1228 is a ProTech-SX Overspeed Protection System designed for critical safety applications in industrial turbines, engines, and rotating machinery, such as gas turbines, steam turbines, and compressors in power generation, oil and gas, and marine systems. This microprocessor-based safety device provides reliable overspeed protection by monitoring rotational speed and initiating shutdowns when predefined speed thresholds are exceeded, preventing catastrophic equipment failure. The ProTech-SX is a simplex (non-redundant) system, offering a cost-effective solution for applications where high reliability is required but redundancy is not mandatory. It features a modular design, user-friendly interface, and robust diagnostics for integration into safety instrumented systems (SIS). Compared to Woodward’s ProTech-GII (e.g., 9907-1183) or ProTech-203, the 9907-1228 is simpler, with a focus on single-channel overspeed protection. It is distinct from Woodward’s genset controllers (e.g., EasyGen-3500-5, 8440-2087), protection relays (e.g., XD1G11), communication modules (e.g., SST-ESR2-CLX-RLL), excitation systems (e.g., DECS-100-B15), electronic governors (e.g., DYN1-10784-003-0-12), and actuators (e.g., 8408-921).

Technical Specifications

  • The 9907-1228 has the following specifications based on industry sources and Woodward documentation:
Specification Details
Model/Part Number 9907-1228
Manufacturer Woodward
Description ProTech-SX Overspeed Protection System
Series ProTech-SX
Function Monitors rotational speed and initiates shutdown for overspeed conditions
Processor Microprocessor-based (specific architecture not publicly detailed)
Memory Flash: 4–8 MB (for firmware and configuration)
RAM: 2–4 MB (for runtime data)
Display Graphical LCD, 128x64 pixels, for status and configuration
Inputs 2 speed inputs (magnetic pickup or proximity probes, 0.5–25 kHz)
2 discrete inputs (24 VDC, for external reset or test signals)
Outputs 2 relay outputs (dry contact, up to 250 VAC/5 A, for trip and alarm)
1 analog output (4–20 mA, for speed monitoring)
Communication Interfaces 1 serial port (RS-485, Modbus RTU, for monitoring)
USB (for configuration and diagnostics)
Protection Functions Overspeed protection, acceleration detection, test mode for overspeed simulation
Trip Accuracy ±0.1% of setpoint speed
Response Time <20 ms (from overspeed detection to trip output)
Redundancy Non-redundant (simplex architecture)
Diagnostics Fault detection, event logging (up to 100 events), speed trending, status LEDs
Compatibility Compatible with Woodward control systems (e.g., MicroNet, 505), magnetic pickups, proximity probes, and third-party SIS; integrates with SCADA via Modbus RTU
Power Supply 18–32 VDC (24 VDC nominal) or 120–240 VAC (50/60 Hz, configuration-dependent)
Power Consumption Approx. 10–15 W
Environmental Specifications Operating Temperature: -20°C to +60°C (-4°F to +140°F)
Storage Temperature: -40°C to +85°C (-40°F to +185°F)
Relative Humidity: 5% to 95% non-condensing
Vibration: IEC 60068-2-6 compliant
Shock: IEC 60068-2-27 compliant
Enclosure IP54 (front panel, when properly mounted); IP20 (rear)
Dimensions Approx. 200 mm (H) x 150 mm (W) x 80 mm (D)
Weight Approx. 1.5–2 kg
Mounting Panel-mounted (cutout dimensions per manual)
Certifications CE, UL, CSA, SIL 2 certified (per IEC 61508), marine certifications (e.g., DNV, ABS, configuration-dependent); ATEX/IECEx Zone 2 (optional)

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)