Product Overview

  • The Woodward 9566-850 is a ProAct Digital Speed Control System designed for precise speed regulation of diesel or gas engines in industrial applications, such as generator sets, marine propulsion, and industrial machinery. Part of Woodward’s ProAct series

Technical Specifications

  • The 9566-850 has the following specifications based on industry sources and Woodward documentation:
Specification Details
Model/Part Number 9566-850
Manufacturer Woodward
Description ProAct Digital Speed Control System for Diesel/Gas Engines
Series ProAct
Function Regulates engine speed, supports load sharing, and controls ProAct actuators
Processor Microprocessor-based (specific architecture not publicly detailed)
Memory Flash: 4–8 MB (for firmware and configuration)
RAM: 2–4 MB (for runtime data)
Display No onboard display; LED indicators for status and faults; configuration via external PC or HMI
Inputs 2 speed inputs (magnetic pickup or proximity probes, 0.5–25 kHz)
4 analog inputs (4–20 mA or 0–5 V, e.g., remote setpoint, load sensor)
4 discrete inputs (24 VDC, for start/stop, reset, or mode selection)
Outputs 1 actuator output (0–200 mA, compatible with ProAct actuators)
2 analog outputs (4–20 mA, for speed or load monitoring)
3 relay outputs (dry contact, up to 250 VAC/2 A, for alarms or trips)
Communication Interfaces 1 serial port (RS-232 or RS-485, Modbus RTU)
1 CANbus port (for engine ECU or system integration)
USB (for configuration and diagnostics)
Control Modes Isochronous, droop, variable speed, load sharing
Speed Regulation Accuracy ±0.25% of rated speed (steady-state)
Protection Functions Overspeed protection, actuator fault detection, loss of speed signal
Redundancy Non-redundant
Diagnostics Fault detection, event logging (up to 100 events), status LEDs, real-time monitoring via Modbus or CANbus
Compatibility Woodward ProAct actuators (e.g., ProAct I, II, III, IV), magnetic pickups, proximity probes, engine ECUs (via CANbus); third-party devices via Modbus RTU; integrates with Woodward control systems (e.g., EasyGen, 505) and SCADA systems
Power Supply 18–32 VDC (24 VDC nominal)
Power Consumption Approx. 10–15 W
Environmental Specifications Operating Temperature: -40°C to +70°C (-40°F to +158°F)
Storage Temperature: -40°C to +85°C (-40°F to +185°F)
Relative Humidity: 5% to 95% non-condensing
Vibration: IEC 60068-2-6 compliant
Shock: IEC 60068-2-27 compliant
Enclosure IP20 (requires enclosure for harsh environments)
Dimensions Approx. 200 mm (H) x 150 mm (W) x 60 mm (D)
Weight Approx. 1–1.5 kg
Mounting Panel-mounted or DIN rail (with adapter)
Certifications CE, UL, CSA, marine certifications (e.g., DNV, ABS, configuration-dependent); ATEX/IECEx Zone 2 (optional)

 

View full details

Product Description

Woodward 9566-850 ProAct Digital Speed Control System

Product Overview

  • The Woodward 9566-850 is a ProAct Digital Speed Control System designed for precise speed regulation of diesel or gas engines in industrial applications, such as generator sets, marine propulsion, and industrial machinery. Part of Woodward’s ProAct series

Technical Specifications

  • The 9566-850 has the following specifications based on industry sources and Woodward documentation:
Specification Details
Model/Part Number 9566-850
Manufacturer Woodward
Description ProAct Digital Speed Control System for Diesel/Gas Engines
Series ProAct
Function Regulates engine speed, supports load sharing, and controls ProAct actuators
Processor Microprocessor-based (specific architecture not publicly detailed)
Memory Flash: 4–8 MB (for firmware and configuration)
RAM: 2–4 MB (for runtime data)
Display No onboard display; LED indicators for status and faults; configuration via external PC or HMI
Inputs 2 speed inputs (magnetic pickup or proximity probes, 0.5–25 kHz)
4 analog inputs (4–20 mA or 0–5 V, e.g., remote setpoint, load sensor)
4 discrete inputs (24 VDC, for start/stop, reset, or mode selection)
Outputs 1 actuator output (0–200 mA, compatible with ProAct actuators)
2 analog outputs (4–20 mA, for speed or load monitoring)
3 relay outputs (dry contact, up to 250 VAC/2 A, for alarms or trips)
Communication Interfaces 1 serial port (RS-232 or RS-485, Modbus RTU)
1 CANbus port (for engine ECU or system integration)
USB (for configuration and diagnostics)
Control Modes Isochronous, droop, variable speed, load sharing
Speed Regulation Accuracy ±0.25% of rated speed (steady-state)
Protection Functions Overspeed protection, actuator fault detection, loss of speed signal
Redundancy Non-redundant
Diagnostics Fault detection, event logging (up to 100 events), status LEDs, real-time monitoring via Modbus or CANbus
Compatibility Woodward ProAct actuators (e.g., ProAct I, II, III, IV), magnetic pickups, proximity probes, engine ECUs (via CANbus); third-party devices via Modbus RTU; integrates with Woodward control systems (e.g., EasyGen, 505) and SCADA systems
Power Supply 18–32 VDC (24 VDC nominal)
Power Consumption Approx. 10–15 W
Environmental Specifications Operating Temperature: -40°C to +70°C (-40°F to +158°F)
Storage Temperature: -40°C to +85°C (-40°F to +185°F)
Relative Humidity: 5% to 95% non-condensing
Vibration: IEC 60068-2-6 compliant
Shock: IEC 60068-2-27 compliant
Enclosure IP20 (requires enclosure for harsh environments)
Dimensions Approx. 200 mm (H) x 150 mm (W) x 60 mm (D)
Weight Approx. 1–1.5 kg
Mounting Panel-mounted or DIN rail (with adapter)
Certifications CE, UL, CSA, marine certifications (e.g., DNV, ABS, configuration-dependent); ATEX/IECEx Zone 2 (optional)

 