Skip to product information
1 of 4

Woodward 8405-052 Actuator

Woodward 8405-052 Actuator

  • Manufacturer: Woodward

  • Product No.: 8405-052

  • Condition:1000 in stock

  • Product Type: Actuator

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 8000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Woodward 8405-052 Actuator

Product Overview

  • The Woodward 8405-052 is a hydraulic actuator designed for precise control of fuel or steam valves in industrial applications, such as gas turbines, steam turbines, and large diesel engines, used in power generation, oil and gas

Technical Specifications

  • The 8405-052 has the following specifications based on industry sources and Woodward actuator documentation:
Specification Details
Model/Part Number 8405-052
Manufacturer Woodward
Description Hydraulic Actuator for Fuel/Steam Valve Control
Series Hydraulic Actuator
Function Provides precise positioning of fuel or steam valves in turbines/engines
Actuator Type Hydraulic, linear (configuration-dependent)
Control Input Analog (4–20 mA, 0–200 mA, or ±10 V)
Feedback Integrated LVDT (Linear Variable Differential Transformer) for position feedback
Stroke Length Approx. 25–75 mm (1–3 inches, configuration-dependent)
Force Output Up to 5,000–15,000 N (1,125–3,375 lbf, configuration-dependent)
Response Time <50 ms (full stroke, depending on hydraulic system)
Hydraulic Pressure Up to 1,500–2,000 psi (103–138 bar, configuration-dependent)
Hydraulic Fluid Standard hydraulic oils (MIL-H-5606 or equivalent)
Position Accuracy ±0.1% of full stroke
Communication Interfaces None (analog control; feedback via LVDT to external controller)
Protection Functions Overpressure protection, position feedback fault detection (via external controller)
Redundancy Non-redundant (redundant systems possible with dual actuators)
Diagnostics Position feedback monitoring, fault detection (via external control system)
Compatibility Woodward control systems (e.g., 505, MicroNet, 2301D, 9905-970), digital drivers (e.g., 8200-314); third-party controllers via analog signals; integrates with fuel/steam valves for turbines and engines
Power Supply Hydraulic (external pump required); electronic control: 18–32 VDC (24 VDC nominal, for LVDT and signal processing)
Power Consumption Approx. 5–10 W (electronic components only)
Environmental Specifications Operating Temperature: -40°C to +85°C (-40°F to +185°F)
Storage Temperature: -40°C to +100°C (-40°F to +212°F)
Relative Humidity: 5% to 95% non-condensing
Vibration: MIL-STD-810 compliant
Shock: MIL-STD-810 compliant
Enclosure IP65 (sealed for harsh environments)
Dimensions Approx. 250 mm (L) x 120 mm (W) x 120 mm (H, configuration-dependent)
Weight Approx. 4–8 kg (9–18 lbs, configuration-dependent)
Mounting Flange or clevis mounting (per valve requirements)
Certifications CE, UL, CSA, marine certifications (e.g., DNV, ABS, configuration-dependent); ATEX/IECEx Zone 1/2 (optional)

 

View full details

Product Description

Woodward 8405-052 Actuator

Product Overview

  • The Woodward 8405-052 is a hydraulic actuator designed for precise control of fuel or steam valves in industrial applications, such as gas turbines, steam turbines, and large diesel engines, used in power generation, oil and gas

Technical Specifications

  • The 8405-052 has the following specifications based on industry sources and Woodward actuator documentation:
Specification Details
Model/Part Number 8405-052
Manufacturer Woodward
Description Hydraulic Actuator for Fuel/Steam Valve Control
Series Hydraulic Actuator
Function Provides precise positioning of fuel or steam valves in turbines/engines
Actuator Type Hydraulic, linear (configuration-dependent)
Control Input Analog (4–20 mA, 0–200 mA, or ±10 V)
Feedback Integrated LVDT (Linear Variable Differential Transformer) for position feedback
Stroke Length Approx. 25–75 mm (1–3 inches, configuration-dependent)
Force Output Up to 5,000–15,000 N (1,125–3,375 lbf, configuration-dependent)
Response Time <50 ms (full stroke, depending on hydraulic system)
Hydraulic Pressure Up to 1,500–2,000 psi (103–138 bar, configuration-dependent)
Hydraulic Fluid Standard hydraulic oils (MIL-H-5606 or equivalent)
Position Accuracy ±0.1% of full stroke
Communication Interfaces None (analog control; feedback via LVDT to external controller)
Protection Functions Overpressure protection, position feedback fault detection (via external controller)
Redundancy Non-redundant (redundant systems possible with dual actuators)
Diagnostics Position feedback monitoring, fault detection (via external control system)
Compatibility Woodward control systems (e.g., 505, MicroNet, 2301D, 9905-970), digital drivers (e.g., 8200-314); third-party controllers via analog signals; integrates with fuel/steam valves for turbines and engines
Power Supply Hydraulic (external pump required); electronic control: 18–32 VDC (24 VDC nominal, for LVDT and signal processing)
Power Consumption Approx. 5–10 W (electronic components only)
Environmental Specifications Operating Temperature: -40°C to +85°C (-40°F to +185°F)
Storage Temperature: -40°C to +100°C (-40°F to +212°F)
Relative Humidity: 5% to 95% non-condensing
Vibration: MIL-STD-810 compliant
Shock: MIL-STD-810 compliant
Enclosure IP65 (sealed for harsh environments)
Dimensions Approx. 250 mm (L) x 120 mm (W) x 120 mm (H, configuration-dependent)
Weight Approx. 4–8 kg (9–18 lbs, configuration-dependent)
Mounting Flange or clevis mounting (per valve requirements)
Certifications CE, UL, CSA, marine certifications (e.g., DNV, ABS, configuration-dependent); ATEX/IECEx Zone 1/2 (optional)

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)