Product Description
Woodward 5503-282 MicroNet Analog I/O Module
Product Overview
- The Woodward 5503-282 is a MicroNet Analog Input/Output (I/O) Module designed for use in Woodward__ MicroNet control system, which controls industrial gas turbines, steam turbines, and compressors in applications such as power generation, oil and gas, and marine systems. This module provides high-precision analog signal interfacing, allowing the MicroNet system to monitor and control parameters like pressure, temperature, flow, or valve position. It features multiple analog inputs and outputs for integration with sensors, actuators, and other field devices. The 5503-282 is optimized for real-time data acquisition and control, with robust diagnostics for reliable operation in demanding environments. Compared to Woodward__ MicroNet CPU modules (e.g., 5501-381), power supply modules (e.g., 5501-432), or genset controllers (e.g., EasyGen-3200-5, 8440-2050E), the 5503-282 is a specialized I/O interface, not a control or power device. It is distinct from Woodward__ protection relays (e.g., XD1G11), servo position controllers (e.g., 8200-226), communication modules (e.g., SST-ESR2-CLX-RLL), excitation systems (e.g., DECS-100-B15), electronic governors (e.g., DYN1-10784-003-0-12), and actuators (e.g., 8408-921).
Technical Specifications
- The 5503-282 has the following specifications based on industry sources and Woodward documentation:
| Specification | Details |
|---|---|
| Model/Part Number | 5503-282 |
| Manufacturer | Woodward |
| Description | MicroNet Analog Input/Output Module |
| Series | MicroNet |
| Function | Interfaces analog signals for monitoring and control in MicroNet systems |
| Processor | Embedded microcontroller (specific architecture not publicly detailed) |
| Memory | Flash: 2_4 MB (for firmware) RAM: 1_2 MB (for runtime data) |
| Display | LED indicators for status, channel activity, and faults |
| Inputs | 16 analog inputs (configurable for 4_20 mA, 0_5 V, 0_10 V, or thermocouples/RTDs) Resolution: 16-bit Accuracy: ±0.1% of full scale |
| Outputs | 8 analog outputs (4_20 mA or 0_10 V) Resolution: 12-bit Accuracy: ±0.2% of full scale |
| Communication Interfaces | MicroNet proprietary bus (for communication with CPU module, e.g., 5501-381 or 5466-419) |
| Supported Signals | Current loops (4_20 mA), voltage signals (0_5 V, 0_10 V), thermocouples (Type J, K, T), RTDs (Pt100, Ni100) |
| Redundancy | Non-redundant (redundant configurations possible with multiple modules) |
| Diagnostics | Fault detection (open circuit, short circuit, out-of-range), channel status, event logging (via CPU module), status LEDs |
| Compatibility | Woodward MicroNet chassis and CPU modules (e.g., 5501-381, 5466-419); sensors and actuators (e.g., pressure transducers, flow meters, Woodward actuators); integrates with MicroNet Simplex or TMR systems |
| Power Supply | 24 VDC (supplied via MicroNet chassis, e.g., 5501-432 power module) |
| Power Consumption | Approx. 5_10 W |
| Environmental Specifications | Operating Temperature: -40°C to +70°C (-40°F to +158°F) Storage Temperature: -40°C to +85°C (-40°F to +185°F) Relative Humidity: 5% to 95% non-condensing Vibration: IEC 60068-2-6 compliant Shock: IEC 60068-2-27 compliant |
| Enclosure | IP20 (installed in MicroNet chassis) |
| Dimensions | Approx. 305 mm (H) x 50 mm (W) x 200 mm (D) |
| Weight | Approx. 0.8_1.2 kg |
| Mounting | Plugs into MicroNet chassis (slot-specific) |
| Certifications | CE, UL, CSA, marine certifications (e.g., DNV, ABS, Lloyd__ Register, configuration-dependent); ATEX/IECEx Zone 2 (optional) |
_