Siemens 6ES7407-0DA02-0AA0 PS 407 20A Power Supply

Siemens 6ES7407-0DA02-0AA0 PS 407 20A Power Supply

  • Manufacturer: Siemens

  • Product No.: 6ES7407-0DA02-0AA0

  • Condition:1000 in stock

  • Product Type: Power Supplies

  • Product Origin: 4019169008235

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Siemens 6ES7407-0DA02-0AA0 PS 407 Power Supply

20A High-Performance Power Supply for S7-400 PLC Systems

The Siemens 6ES7407-0DA02-0AA0 is a robust 20-ampere power supply module designed for SIMATIC S7-400 automation systems. This PS 407 unit delivers reliable, regulated power to support large-scale PLC configurations with extensive I/O modules and communication processors.


💡 Why PS 407 20A?

  • High Current Capacity – 20A output supports up to 18 modules in UR2/CR2 racks
  • Wide Input Range – 120-230V AC auto-sensing for global deployment
  • Redundancy Ready – Parallel operation with second PS for N+1 backup
  • Diagnostic LEDs – Real-time status monitoring (ON, FAULT, DC OK)
  • Overload Protection – Automatic shutdown prevents module damage
  • Hot-Swap Capable – Replace without system shutdown (in redundant configs)

📋 Technical Specifications

Order Number 6ES7407-0DA02-0AA0
Product Family PS 407 Power Supply
Output Current 20A @ 5V DC
Output Power 100W (5V DC output)
Input Voltage 120-230V AC (auto-sensing)
Input Frequency 47-63 Hz
Efficiency Typ. 85%
Inrush Current Max. 20A @ 230V AC
Hold-Up Time Min. 20ms @ 230V AC
Isolation Safe isolation per IEC 61131-2
Operating Temp 0°C to +60°C (horizontal mounting)
Storage Temp -40°C to +70°C
Humidity 5% to 95% RH (non-condensing)
Dimensions (W×H×D) 50mm × 290mm × 219mm
Weight Approx. 1.5 kg
MTBF >300,000 hours
Certifications CE, UL 508, cULus, FM, ATEX, IECEx

🔌 System Compatibility

Compatible Racks:

  • UR1 (9-slot) – 6ES7400-1JA01-0AA0
  • UR2 (18-slot) – 6ES7400-1JA11-0AA0
  • CR2 (18-slot segmented) – 6ES7400-2JA00-0AA0
  • ER1/ER2 expansion racks

Compatible CPUs: All S7-400 CPUs (CPU 412, 414, 416, 417 series)

Module Support: Powers up to 18 modules including CPU, I/O, communication processors, and function modules


📊 Power Supply Sizing Guide

PS Model Output Current Max Modules Typical Use Case
PS 405 5A 5A Up to 8 modules Small systems, UR1 racks
PS 405 10A 10A Up to 12 modules Medium systems
PS 407 10A 10A Up to 12 modules Standard UR2 configurations
PS 407 20A (This Product) 20A Up to 18 modules Large systems, full UR2/CR2 racks

How to Calculate Power Requirements

  1. List all modules in your rack (CPU, I/O, CP, FM)
  2. Find current consumption in each module's datasheet (typically 0.5-2A per module)
  3. Sum total current draw
  4. Add 20% safety margin
  5. Select PS with capacity ≥ total current + margin

Example: CPU 416 (1.5A) + 10× SM 421 (0.5A each) + 2× CP 443 (1A each) = 1.5 + 5 + 2 = 8.5A × 1.2 = 10.2A → Choose PS 407 20A for future expansion


🛠️ Installation Guide

Mounting Position

The PS 407 must be installed in Slot 1 (leftmost position) of the S7-400 rack. This is a fixed requirement per Siemens design.

Step-by-Step Installation

  1. Pre-Installation
    • Verify input voltage matches your facility (120V or 230V AC)
    • Ensure rack is properly grounded
    • Calculate total module current draw (see sizing guide above)
  2. Physical Installation
    • Slide PS 407 into Slot 1 from the front
    • Push firmly until module seats on backplane connectors
    • Engage top and bottom locking screws
  3. Wiring
    • Connect L (Line), N (Neutral), PE (Ground) to input terminals
    • Use minimum 14 AWG wire for 20A capacity
    • Tighten terminals to 0.5-0.6 Nm torque
    • Verify PE connection has <0.1Ω resistance to cabinet ground
  4. Power-Up
    • Switch on AC input power
    • Verify green ON LED illuminates
    • Check DC OK LED (green = normal output)
    • Monitor FAULT LED (off = no errors)

💡 Best Practices

  • Use circuit breaker rated for 20A input current
  • Install surge protection on AC input for harsh environments
  • Leave 50mm clearance above PS for ventilation
  • For redundancy, install second PS 407 in parallel (requires CR2 rack)

🏭 Industry Applications

Automotive Manufacturing
Power large S7-400 systems controlling body-in-white welding lines with 15+ I/O modules and multiple CP 443 Profinet gateways.

Oil & Gas
Support redundant S7-400H configurations in offshore platforms where 20A capacity enables N+1 power supply backup.

Chemical Processing
Drive batch control systems with extensive analog I/O (SM 431/432) and safety modules requiring high current draw.

Power Generation
Operate turbine control systems with multiple function modules (FM 458) for high-speed position control.


🔧 Diagnostics & Troubleshooting

LED Indicators

LED Status Meaning
ON (Green) Lit AC input present, PS operating normally
Off No AC input or PS failure
DC OK (Green) Lit 5V DC output within tolerance
Off Output voltage out of range or overload
FAULT (Red) Off Normal operation
Lit Overload, overvoltage, or thermal shutdown

Common Issues

Problem Cause Solution
FAULT LED on Overload (current >20A) Remove modules or upgrade to redundant PS
DC OK LED off Output short circuit Check for wiring faults, damaged modules
System random resets Insufficient hold-up time Check AC input quality, add UPS if needed
PS overheating Poor ventilation Ensure 50mm clearance, check fan operation

🛡️ Authenticity Guarantee

⚠️ Counterfeit Power Supply Risks

Non-genuine PS 407 modules can cause:

  • 🔥 Voltage instability leading to CPU crashes
  • ⚡ Insufficient current capacity causing brownouts
  • 💥 Fire hazards from substandard components
  • 🚫 Voided Siemens warranty on entire system
  • ⚖️ Regulatory non-compliance (UL, CE, ATEX)

✅ Industrial Control Hub Guarantee

  • 🔒 100% Genuine Siemens – Factory-sealed with holographic labels
  • 📜 Full Traceability – Serial numbers and manufacturing dates
  • 🌍 Authorized Distributor – Verify at Siemens Industry Mall
  • 🛡️ 24-Month Warranty – Manufacturer warranty honored globally
  • 📦 Secure Packaging – Anti-static protection during shipping

📦 Package Contents

  • 1× Siemens 6ES7407-0DA02-0AA0 PS 407 power supply (20A)
  • Terminal block cover
  • Product documentation and certificate of conformity

Note: Rack and modules are NOT included. Order separately based on your system requirements.


🤝 Technical Support

  • 📧 Power Sizing Consultation – Email us your module list for PS recommendations
  • 📚 Documentation – Access Siemens manuals, wiring diagrams, and datasheets
  • 🎓 Training Resources – Installation guides and troubleshooting tips
  • 🔄 30-Day Returns – Hassle-free returns if unused and in original packaging

❓ FAQ

Q: Can I use this PS with S7-300 systems?
A: No, PS 407 is exclusively for S7-400. S7-300 uses PS 307 series power supplies.

Q: What's the difference between PS 405 and PS 407?
A: PS 407 has higher efficiency, better hold-up time, and supports redundant operation. PS 405 is more cost-effective for smaller systems.

Q: Can I run two PS 407 in parallel?
A: Yes, in CR2 segmented racks for N+1 redundancy. Each PS powers one segment independently.

Q: Does this PS work with 110V AC input?
A: Yes, it auto-senses 120-230V AC. No manual switching required.

Q: How do I know if I need 10A or 20A?
A: Calculate total module current draw + 20% margin. If >10A, choose 20A model for safety.

View full details

Product Description

Siemens 6ES7407-0DA02-0AA0 PS 407 Power Supply

20A High-Performance Power Supply for S7-400 PLC Systems

The Siemens 6ES7407-0DA02-0AA0 is a robust 20-ampere power supply module designed for SIMATIC S7-400 automation systems. This PS 407 unit delivers reliable, regulated power to support large-scale PLC configurations with extensive I/O modules and communication processors.


💡 Why PS 407 20A?

  • High Current Capacity – 20A output supports up to 18 modules in UR2/CR2 racks
  • Wide Input Range – 120-230V AC auto-sensing for global deployment
  • Redundancy Ready – Parallel operation with second PS for N+1 backup
  • Diagnostic LEDs – Real-time status monitoring (ON, FAULT, DC OK)
  • Overload Protection – Automatic shutdown prevents module damage
  • Hot-Swap Capable – Replace without system shutdown (in redundant configs)

📋 Technical Specifications

Order Number 6ES7407-0DA02-0AA0
Product Family PS 407 Power Supply
Output Current 20A @ 5V DC
Output Power 100W (5V DC output)
Input Voltage 120-230V AC (auto-sensing)
Input Frequency 47-63 Hz
Efficiency Typ. 85%
Inrush Current Max. 20A @ 230V AC
Hold-Up Time Min. 20ms @ 230V AC
Isolation Safe isolation per IEC 61131-2
Operating Temp 0°C to +60°C (horizontal mounting)
Storage Temp -40°C to +70°C
Humidity 5% to 95% RH (non-condensing)
Dimensions (W×H×D) 50mm × 290mm × 219mm
Weight Approx. 1.5 kg
MTBF >300,000 hours
Certifications CE, UL 508, cULus, FM, ATEX, IECEx

🔌 System Compatibility

Compatible Racks:

  • UR1 (9-slot) – 6ES7400-1JA01-0AA0
  • UR2 (18-slot) – 6ES7400-1JA11-0AA0
  • CR2 (18-slot segmented) – 6ES7400-2JA00-0AA0
  • ER1/ER2 expansion racks

Compatible CPUs: All S7-400 CPUs (CPU 412, 414, 416, 417 series)

Module Support: Powers up to 18 modules including CPU, I/O, communication processors, and function modules


📊 Power Supply Sizing Guide

PS Model Output Current Max Modules Typical Use Case
PS 405 5A 5A Up to 8 modules Small systems, UR1 racks
PS 405 10A 10A Up to 12 modules Medium systems
PS 407 10A 10A Up to 12 modules Standard UR2 configurations
PS 407 20A (This Product) 20A Up to 18 modules Large systems, full UR2/CR2 racks

How to Calculate Power Requirements

  1. List all modules in your rack (CPU, I/O, CP, FM)
  2. Find current consumption in each module's datasheet (typically 0.5-2A per module)
  3. Sum total current draw
  4. Add 20% safety margin
  5. Select PS with capacity ≥ total current + margin

Example: CPU 416 (1.5A) + 10× SM 421 (0.5A each) + 2× CP 443 (1A each) = 1.5 + 5 + 2 = 8.5A × 1.2 = 10.2A → Choose PS 407 20A for future expansion


🛠️ Installation Guide

Mounting Position

The PS 407 must be installed in Slot 1 (leftmost position) of the S7-400 rack. This is a fixed requirement per Siemens design.

Step-by-Step Installation

  1. Pre-Installation
    • Verify input voltage matches your facility (120V or 230V AC)
    • Ensure rack is properly grounded
    • Calculate total module current draw (see sizing guide above)
  2. Physical Installation
    • Slide PS 407 into Slot 1 from the front
    • Push firmly until module seats on backplane connectors
    • Engage top and bottom locking screws
  3. Wiring
    • Connect L (Line), N (Neutral), PE (Ground) to input terminals
    • Use minimum 14 AWG wire for 20A capacity
    • Tighten terminals to 0.5-0.6 Nm torque
    • Verify PE connection has <0.1Ω resistance to cabinet ground
  4. Power-Up
    • Switch on AC input power
    • Verify green ON LED illuminates
    • Check DC OK LED (green = normal output)
    • Monitor FAULT LED (off = no errors)

💡 Best Practices

  • Use circuit breaker rated for 20A input current
  • Install surge protection on AC input for harsh environments
  • Leave 50mm clearance above PS for ventilation
  • For redundancy, install second PS 407 in parallel (requires CR2 rack)

🏭 Industry Applications

Automotive Manufacturing
Power large S7-400 systems controlling body-in-white welding lines with 15+ I/O modules and multiple CP 443 Profinet gateways.

Oil & Gas
Support redundant S7-400H configurations in offshore platforms where 20A capacity enables N+1 power supply backup.

Chemical Processing
Drive batch control systems with extensive analog I/O (SM 431/432) and safety modules requiring high current draw.

Power Generation
Operate turbine control systems with multiple function modules (FM 458) for high-speed position control.


🔧 Diagnostics & Troubleshooting

LED Indicators

LED Status Meaning
ON (Green) Lit AC input present, PS operating normally
Off No AC input or PS failure
DC OK (Green) Lit 5V DC output within tolerance
Off Output voltage out of range or overload
FAULT (Red) Off Normal operation
Lit Overload, overvoltage, or thermal shutdown

Common Issues

Problem Cause Solution
FAULT LED on Overload (current >20A) Remove modules or upgrade to redundant PS
DC OK LED off Output short circuit Check for wiring faults, damaged modules
System random resets Insufficient hold-up time Check AC input quality, add UPS if needed
PS overheating Poor ventilation Ensure 50mm clearance, check fan operation

🛡️ Authenticity Guarantee

⚠️ Counterfeit Power Supply Risks

Non-genuine PS 407 modules can cause:

  • 🔥 Voltage instability leading to CPU crashes
  • ⚡ Insufficient current capacity causing brownouts
  • 💥 Fire hazards from substandard components
  • 🚫 Voided Siemens warranty on entire system
  • ⚖️ Regulatory non-compliance (UL, CE, ATEX)

✅ Industrial Control Hub Guarantee

  • 🔒 100% Genuine Siemens – Factory-sealed with holographic labels
  • 📜 Full Traceability – Serial numbers and manufacturing dates
  • 🌍 Authorized Distributor – Verify at Siemens Industry Mall
  • 🛡️ 24-Month Warranty – Manufacturer warranty honored globally
  • 📦 Secure Packaging – Anti-static protection during shipping

📦 Package Contents

  • 1× Siemens 6ES7407-0DA02-0AA0 PS 407 power supply (20A)
  • Terminal block cover
  • Product documentation and certificate of conformity

Note: Rack and modules are NOT included. Order separately based on your system requirements.


🤝 Technical Support

  • 📧 Power Sizing Consultation – Email us your module list for PS recommendations
  • 📚 Documentation – Access Siemens manuals, wiring diagrams, and datasheets
  • 🎓 Training Resources – Installation guides and troubleshooting tips
  • 🔄 30-Day Returns – Hassle-free returns if unused and in original packaging

❓ FAQ

Q: Can I use this PS with S7-300 systems?
A: No, PS 407 is exclusively for S7-400. S7-300 uses PS 307 series power supplies.

Q: What's the difference between PS 405 and PS 407?
A: PS 407 has higher efficiency, better hold-up time, and supports redundant operation. PS 405 is more cost-effective for smaller systems.

Q: Can I run two PS 407 in parallel?
A: Yes, in CR2 segmented racks for N+1 redundancy. Each PS powers one segment independently.

Q: Does this PS work with 110V AC input?
A: Yes, it auto-senses 120-230V AC. No manual switching required.

Q: How do I know if I need 10A or 20A?
A: Calculate total module current draw + 20% margin. If >10A, choose 20A model for safety.