Product Description
Siemens 6ES7407-0DA02-0AA0 PS 407 Power Supply
20A High-Performance Power Supply for S7-400 PLC Systems
The Siemens 6ES7407-0DA02-0AA0 is a robust 20-ampere power supply module designed for SIMATIC S7-400 automation systems. This PS 407 unit delivers reliable, regulated power to support large-scale PLC configurations with extensive I/O modules and communication processors.
💡 Why PS 407 20A?
- ✅ High Current Capacity – 20A output supports up to 18 modules in UR2/CR2 racks
- ✅ Wide Input Range – 120-230V AC auto-sensing for global deployment
- ✅ Redundancy Ready – Parallel operation with second PS for N+1 backup
- ✅ Diagnostic LEDs – Real-time status monitoring (ON, FAULT, DC OK)
- ✅ Overload Protection – Automatic shutdown prevents module damage
- ✅ Hot-Swap Capable – Replace without system shutdown (in redundant configs)
📋 Technical Specifications
| Order Number | 6ES7407-0DA02-0AA0 |
| Product Family | PS 407 Power Supply |
| Output Current | 20A @ 5V DC |
| Output Power | 100W (5V DC output) |
| Input Voltage | 120-230V AC (auto-sensing) |
| Input Frequency | 47-63 Hz |
| Efficiency | Typ. 85% |
| Inrush Current | Max. 20A @ 230V AC |
| Hold-Up Time | Min. 20ms @ 230V AC |
| Isolation | Safe isolation per IEC 61131-2 |
| Operating Temp | 0°C to +60°C (horizontal mounting) |
| Storage Temp | -40°C to +70°C |
| Humidity | 5% to 95% RH (non-condensing) |
| Dimensions (W×H×D) | 50mm × 290mm × 219mm |
| Weight | Approx. 1.5 kg |
| MTBF | >300,000 hours |
| Certifications | CE, UL 508, cULus, FM, ATEX, IECEx |
🔌 System Compatibility
Compatible Racks:
- UR1 (9-slot) – 6ES7400-1JA01-0AA0
- UR2 (18-slot) – 6ES7400-1JA11-0AA0
- CR2 (18-slot segmented) – 6ES7400-2JA00-0AA0
- ER1/ER2 expansion racks
Compatible CPUs: All S7-400 CPUs (CPU 412, 414, 416, 417 series)
Module Support: Powers up to 18 modules including CPU, I/O, communication processors, and function modules
📊 Power Supply Sizing Guide
| PS Model | Output Current | Max Modules | Typical Use Case |
|---|---|---|---|
| PS 405 5A | 5A | Up to 8 modules | Small systems, UR1 racks |
| PS 405 10A | 10A | Up to 12 modules | Medium systems |
| PS 407 10A | 10A | Up to 12 modules | Standard UR2 configurations |
| PS 407 20A (This Product) | 20A | Up to 18 modules | Large systems, full UR2/CR2 racks |
How to Calculate Power Requirements
- List all modules in your rack (CPU, I/O, CP, FM)
- Find current consumption in each module's datasheet (typically 0.5-2A per module)
- Sum total current draw
- Add 20% safety margin
- Select PS with capacity ≥ total current + margin
Example: CPU 416 (1.5A) + 10× SM 421 (0.5A each) + 2× CP 443 (1A each) = 1.5 + 5 + 2 = 8.5A × 1.2 = 10.2A → Choose PS 407 20A for future expansion
🛠️ Installation Guide
Mounting Position
The PS 407 must be installed in Slot 1 (leftmost position) of the S7-400 rack. This is a fixed requirement per Siemens design.
Step-by-Step Installation
-
Pre-Installation
- Verify input voltage matches your facility (120V or 230V AC)
- Ensure rack is properly grounded
- Calculate total module current draw (see sizing guide above)
-
Physical Installation
- Slide PS 407 into Slot 1 from the front
- Push firmly until module seats on backplane connectors
- Engage top and bottom locking screws
-
Wiring
- Connect L (Line), N (Neutral), PE (Ground) to input terminals
- Use minimum 14 AWG wire for 20A capacity
- Tighten terminals to 0.5-0.6 Nm torque
- Verify PE connection has <0.1Ω resistance to cabinet ground
-
Power-Up
- Switch on AC input power
- Verify green ON LED illuminates
- Check DC OK LED (green = normal output)
- Monitor FAULT LED (off = no errors)
💡 Best Practices
- Use circuit breaker rated for 20A input current
- Install surge protection on AC input for harsh environments
- Leave 50mm clearance above PS for ventilation
- For redundancy, install second PS 407 in parallel (requires CR2 rack)
🏭 Industry Applications
Automotive Manufacturing
Power large S7-400 systems controlling body-in-white welding lines with 15+ I/O modules and multiple CP 443 Profinet gateways.
Oil & Gas
Support redundant S7-400H configurations in offshore platforms where 20A capacity enables N+1 power supply backup.
Chemical Processing
Drive batch control systems with extensive analog I/O (SM 431/432) and safety modules requiring high current draw.
Power Generation
Operate turbine control systems with multiple function modules (FM 458) for high-speed position control.
🔧 Diagnostics & Troubleshooting
LED Indicators
| LED | Status | Meaning |
|---|---|---|
| ON (Green) | Lit | AC input present, PS operating normally |
| Off | No AC input or PS failure | |
| DC OK (Green) | Lit | 5V DC output within tolerance |
| Off | Output voltage out of range or overload | |
| FAULT (Red) | Off | Normal operation |
| Lit | Overload, overvoltage, or thermal shutdown |
Common Issues
| Problem | Cause | Solution |
|---|---|---|
| FAULT LED on | Overload (current >20A) | Remove modules or upgrade to redundant PS |
| DC OK LED off | Output short circuit | Check for wiring faults, damaged modules |
| System random resets | Insufficient hold-up time | Check AC input quality, add UPS if needed |
| PS overheating | Poor ventilation | Ensure 50mm clearance, check fan operation |
🛡️ Authenticity Guarantee
⚠️ Counterfeit Power Supply Risks
Non-genuine PS 407 modules can cause:
- 🔥 Voltage instability leading to CPU crashes
- ⚡ Insufficient current capacity causing brownouts
- 💥 Fire hazards from substandard components
- 🚫 Voided Siemens warranty on entire system
- ⚖️ Regulatory non-compliance (UL, CE, ATEX)
✅ Industrial Control Hub Guarantee
- 🔒 100% Genuine Siemens – Factory-sealed with holographic labels
- 📜 Full Traceability – Serial numbers and manufacturing dates
- 🌍 Authorized Distributor – Verify at Siemens Industry Mall
- 🛡️ 24-Month Warranty – Manufacturer warranty honored globally
- 📦 Secure Packaging – Anti-static protection during shipping
📦 Package Contents
- 1× Siemens 6ES7407-0DA02-0AA0 PS 407 power supply (20A)
- Terminal block cover
- Product documentation and certificate of conformity
Note: Rack and modules are NOT included. Order separately based on your system requirements.
🤝 Technical Support
- 📧 Power Sizing Consultation – Email us your module list for PS recommendations
- 📚 Documentation – Access Siemens manuals, wiring diagrams, and datasheets
- 🎓 Training Resources – Installation guides and troubleshooting tips
- 🔄 30-Day Returns – Hassle-free returns if unused and in original packaging
❓ FAQ
Q: Can I use this PS with S7-300 systems?
A: No, PS 407 is exclusively for S7-400. S7-300 uses PS 307 series power supplies.
Q: What's the difference between PS 405 and PS 407?
A: PS 407 has higher efficiency, better hold-up time, and supports redundant operation. PS 405 is more cost-effective for smaller systems.
Q: Can I run two PS 407 in parallel?
A: Yes, in CR2 segmented racks for N+1 redundancy. Each PS powers one segment independently.
Q: Does this PS work with 110V AC input?
A: Yes, it auto-senses 120-230V AC. No manual switching required.
Q: How do I know if I need 10A or 20A?
A: Calculate total module current draw + 20% margin. If >10A, choose 20A model for safety.