Skip to product information
1 of 3

Siemens 6ES7407-0DA00-0AA0 PS 407 10A Power Supply S7-400

Siemens 6ES7407-0DA00-0AA0 PS 407 10A Power Supply S7-400

  • Manufacturer: Siemens

  • Product No.: 6ES7407-0DA00-0AA0

  • Condition:1000 in stock

  • Product Type: Power Supplies

  • Product Origin: 4019169006040

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Siemens 6ES7407-0DA00-0AA0 PS 407 Power Supply

10A High-Performance Power Supply for SIMATIC S7-400 PLC Systems

The Siemens 6ES7407-0DA00-0AA0 is a robust 10A power supply module (PS 407) engineered for demanding S7-400 automation systems. This industrial-grade power module delivers stable 5V DC and 24V DC outputs to support high-density I/O configurations and redundant CPU architectures in mission-critical applications.


💡 Why PS 407 10A?

Power supply selection is critical for S7-400 system reliability. The PS 407 10A offers:

  • High Current Capacity – 10A @ 5V DC supports up to 18 modules per rack
  • Wide Input Range – 120-230V AC or 110-300V DC for global deployment
  • Redundancy Ready – Parallel operation with second PS for N+1 redundancy
  • Diagnostic LEDs – Real-time status monitoring (ON, DC OK, FAULT)
  • Overload Protection – Automatic shutdown prevents cascade failures
  • Hot-Swap Capable – Replace without system shutdown (in redundant configs)

📋 Technical Specifications

Order Number 6ES7407-0DA00-0AA0
Product Family PS 407 Power Supply
Output Current 10A @ 5V DC
Output Voltage 5V DC ±3% (for backplane)
24V DC ±3% (for I/O modules)
Input Voltage AC 120-230V AC, 50/60 Hz
Input Voltage DC 110-300V DC
Input Current Max. 2.5A @ 120V AC
Power Consumption Typ. 75W (no load), Max. 120W (full load)
Efficiency >85% (typical)
Inrush Current Max. 20A @ 230V AC (limited to 2ms)
Hold-Up Time Min. 20ms @ 230V AC (power failure bridging)
Isolation Input to output: 4kV AC
Input to ground: 2kV AC
Operating Temp 0°C to +60°C (horizontal mounting)
0°C to +40°C (vertical mounting)
Storage Temp -40°C to +70°C
Humidity 5% to 95% RH (non-condensing)
MTBF >300,000 hours @ 40°C
Dimensions (W×H×D) 50mm × 290mm × 219mm
Weight Approx. 1.2 kg
Certifications CE, UL 508, cULus, FM, ATEX, IECEx, GL, DNV

🔌 System Compatibility

Compatible Racks:

  • UR1 (9-slot): 6ES7400-1JA01-0AA0
  • UR2 (18-slot): 6ES7400-1JA11-0AA0
  • ER1 (9-slot expansion): 6ES7400-1TA01-0AA0
  • ER2 (18-slot expansion): 6ES7400-1TA11-0AA0
  • CR2 (18-slot segmented): 6ES7400-2JA00-0AA0

Compatible CPUs: All S7-400 CPUs (CPU 412, 414, 416, 417 series)

Mounting Position: Slot 1 (leftmost position in rack)


⚡ Power Budget Calculation

Current Consumption Examples

Module Type Typical Current @ 5V Qty Supported (10A PS)
CPU 414-3 1.2A 1 (mandatory)
SM 421 (32 DI) 0.3A Up to 29 modules
SM 422 (32 DO) 0.4A Up to 22 modules
SM 431 (8 AI) 0.5A Up to 18 modules
CP 443-1 (Ethernet) 0.6A Up to 15 modules

Calculation Formula:

Total Current = CPU + Σ(I/O Modules) + 20% Safety Margin

Example Configuration (UR2 18-slot):

  • 1× CPU 414-3: 1.2A
  • 10× SM 421 DI: 3.0A
  • 5× SM 422 DO: 2.0A
  • 1× CP 443-1: 0.6A
  • Safety Margin (20%): 1.4A
  • Total: 8.2A ✅ Within 10A capacity

⚠️ Important: If total exceeds 10A, upgrade to PS 407 20A (6ES7407-0KR02-0AA0) or add redundant power supply.


🔄 Redundancy Configuration

For high-availability systems, deploy two PS 407 modules in parallel:

N+1 Redundancy Setup

  1. Install primary PS 407 in Slot 1
  2. Install secondary PS 407 in Slot 2 (requires special mounting kit)
  3. Both power supplies share load equally (5A each for 10A total)
  4. If one fails, the other automatically supplies full 10A
  5. Hot-swap failed unit without system shutdown

Benefits:

  • Zero downtime during power supply failures
  • Extended MTBF through load sharing
  • Maintenance without production interruption

🏭 Industry Applications

Oil & Gas
Power redundant S7-400H systems in offshore platforms and pipeline control stations. Wide DC input range supports UPS-backed installations.

Power Generation
Supply turbine control systems and SCADA networks in coal, gas, and nuclear plants. High MTBF ensures continuous operation.

Automotive Manufacturing
Drive body-in-white welding lines and paint shop automation with high-density I/O configurations requiring 10A capacity.

Chemical Processing
Support batch control and safety instrumented systems (SIS) in ATEX/IECEx hazardous areas.


🛠️ Installation Guide

Pre-Installation Checks

  • ✓ Verify input voltage matches PS rating (120-230V AC or 110-300V DC)
  • ✓ Calculate total module current consumption (must be <10A)
  • ✓ Ensure adequate ventilation (50mm clearance above/below rack)
  • ✓ Confirm grounding infrastructure (PE connection required)

Installation Steps

  1. Power Down – De-energize all input power sources
  2. Mount PS – Insert PS 407 into Slot 1 of S7-400 rack, push until fully seated
  3. Lock Module – Engage locking mechanism to prevent accidental removal
  4. Wire Input – Connect L1, N (AC) or L+, M (DC) to input terminals, tighten to 0.5-0.6 Nm
  5. Ground Connection – Connect PE terminal to cabinet ground rail
  6. Power Up – Energize input, verify green ON LED illuminates
  7. Check Diagnostics – Verify DC OK LED is green (no FAULT LED)

🔧 Troubleshooting

LED Status Meaning Action
ON (green) Input power present Normal operation
DC OK (green) Output voltage stable Normal operation
FAULT (red) Overload or short circuit Check module current consumption, remove faulty modules
No LEDs No input power Verify input wiring, check circuit breaker
ON but no DC OK Output overload Reduce module count or upgrade to 20A PS

📊 PS 407 Model Comparison

Model Order Number Output Current Max Modules Best For
PS 407 5A 6ES7407-0KA02-0AA0 5A @ 5V DC Up to 9 modules Compact systems (UR1)
PS 407 10A 6ES7407-0DA00-0AA0 (This Product) 10A @ 5V DC Up to 18 modules Standard systems (UR2)
PS 407 20A 6ES7407-0KR02-0AA0 20A @ 5V DC Up to 36 modules Large systems, redundancy

🛡️ Authenticity Guarantee

⚠️ Counterfeit Power Supply Risks

Non-genuine power supplies can cause catastrophic failures:

  • 🔥 Voltage instability damaging CPUs and I/O modules
  • ⚡ Insufficient current causing intermittent system crashes
  • 💥 Fire hazards from substandard components
  • 🚫 Voided Siemens warranty on entire system
  • ⚖️ Regulatory non-compliance (UL, CE, ATEX)

✅ Industrial Control Hub Guarantee

  • 🔒 100% Genuine Siemens – Factory-sealed with holographic labels
  • 📜 Full Traceability – Serial numbers and manufacturing dates
  • 🌍 Authorized Distributor – Verify at Siemens Industry Mall
  • 🛡️ 24-Month Warranty – Global manufacturer warranty
  • 📦 Secure Packaging – ESD protection during shipping

📦 Package Contents

  • 1× Siemens 6ES7407-0DA00-0AA0 PS 407 power supply (10A)
  • Terminal block cover
  • Product documentation and certificate of conformity

Note: Input wiring and rack are NOT included. Order separately.


🤝 Technical Support

  • 📧 Power Budget Consultation – Email us your module list for sizing verification
  • 📚 Documentation – Manuals, wiring diagrams, and datasheets
  • 🎓 Training Resources – Power supply selection and installation guides
  • 🔄 30-Day Returns – Hassle-free returns if unused

❓ FAQ

Q: Can I use this PS with S7-300 systems?
A: No, PS 407 is exclusively for S7-400. S7-300 uses PS 307 series.

Q: What's the difference between 10A and 20A models?
A: 10A supports up to 18 modules, 20A supports up to 36 modules. Choose based on total current consumption.

Q: Can I mix AC and DC input power supplies in the same rack?
A: Yes, but both must have the same output current rating for redundancy.

Q: How do I calculate if 10A is sufficient?
A: Sum all module currents from datasheets, add 20% safety margin. If total <10A, this PS is adequate.

Q: Does this support 110V AC input?
A: Yes, input range is 120-230V AC. 110V is within tolerance.

Q: Can I hot-swap this power supply?
A: Only in redundant configurations with a second PS installed. Never in single-PS systems.

View full details

Product Description

Siemens 6ES7407-0DA00-0AA0 PS 407 Power Supply

10A High-Performance Power Supply for SIMATIC S7-400 PLC Systems

The Siemens 6ES7407-0DA00-0AA0 is a robust 10A power supply module (PS 407) engineered for demanding S7-400 automation systems. This industrial-grade power module delivers stable 5V DC and 24V DC outputs to support high-density I/O configurations and redundant CPU architectures in mission-critical applications.


💡 Why PS 407 10A?

Power supply selection is critical for S7-400 system reliability. The PS 407 10A offers:

  • High Current Capacity – 10A @ 5V DC supports up to 18 modules per rack
  • Wide Input Range – 120-230V AC or 110-300V DC for global deployment
  • Redundancy Ready – Parallel operation with second PS for N+1 redundancy
  • Diagnostic LEDs – Real-time status monitoring (ON, DC OK, FAULT)
  • Overload Protection – Automatic shutdown prevents cascade failures
  • Hot-Swap Capable – Replace without system shutdown (in redundant configs)

📋 Technical Specifications

Order Number 6ES7407-0DA00-0AA0
Product Family PS 407 Power Supply
Output Current 10A @ 5V DC
Output Voltage 5V DC ±3% (for backplane)
24V DC ±3% (for I/O modules)
Input Voltage AC 120-230V AC, 50/60 Hz
Input Voltage DC 110-300V DC
Input Current Max. 2.5A @ 120V AC
Power Consumption Typ. 75W (no load), Max. 120W (full load)
Efficiency >85% (typical)
Inrush Current Max. 20A @ 230V AC (limited to 2ms)
Hold-Up Time Min. 20ms @ 230V AC (power failure bridging)
Isolation Input to output: 4kV AC
Input to ground: 2kV AC
Operating Temp 0°C to +60°C (horizontal mounting)
0°C to +40°C (vertical mounting)
Storage Temp -40°C to +70°C
Humidity 5% to 95% RH (non-condensing)
MTBF >300,000 hours @ 40°C
Dimensions (W×H×D) 50mm × 290mm × 219mm
Weight Approx. 1.2 kg
Certifications CE, UL 508, cULus, FM, ATEX, IECEx, GL, DNV

🔌 System Compatibility

Compatible Racks:

  • UR1 (9-slot): 6ES7400-1JA01-0AA0
  • UR2 (18-slot): 6ES7400-1JA11-0AA0
  • ER1 (9-slot expansion): 6ES7400-1TA01-0AA0
  • ER2 (18-slot expansion): 6ES7400-1TA11-0AA0
  • CR2 (18-slot segmented): 6ES7400-2JA00-0AA0

Compatible CPUs: All S7-400 CPUs (CPU 412, 414, 416, 417 series)

Mounting Position: Slot 1 (leftmost position in rack)


⚡ Power Budget Calculation

Current Consumption Examples

Module Type Typical Current @ 5V Qty Supported (10A PS)
CPU 414-3 1.2A 1 (mandatory)
SM 421 (32 DI) 0.3A Up to 29 modules
SM 422 (32 DO) 0.4A Up to 22 modules
SM 431 (8 AI) 0.5A Up to 18 modules
CP 443-1 (Ethernet) 0.6A Up to 15 modules

Calculation Formula:

Total Current = CPU + Σ(I/O Modules) + 20% Safety Margin

Example Configuration (UR2 18-slot):

  • 1× CPU 414-3: 1.2A
  • 10× SM 421 DI: 3.0A
  • 5× SM 422 DO: 2.0A
  • 1× CP 443-1: 0.6A
  • Safety Margin (20%): 1.4A
  • Total: 8.2A ✅ Within 10A capacity

⚠️ Important: If total exceeds 10A, upgrade to PS 407 20A (6ES7407-0KR02-0AA0) or add redundant power supply.


🔄 Redundancy Configuration

For high-availability systems, deploy two PS 407 modules in parallel:

N+1 Redundancy Setup

  1. Install primary PS 407 in Slot 1
  2. Install secondary PS 407 in Slot 2 (requires special mounting kit)
  3. Both power supplies share load equally (5A each for 10A total)
  4. If one fails, the other automatically supplies full 10A
  5. Hot-swap failed unit without system shutdown

Benefits:

  • Zero downtime during power supply failures
  • Extended MTBF through load sharing
  • Maintenance without production interruption

🏭 Industry Applications

Oil & Gas
Power redundant S7-400H systems in offshore platforms and pipeline control stations. Wide DC input range supports UPS-backed installations.

Power Generation
Supply turbine control systems and SCADA networks in coal, gas, and nuclear plants. High MTBF ensures continuous operation.

Automotive Manufacturing
Drive body-in-white welding lines and paint shop automation with high-density I/O configurations requiring 10A capacity.

Chemical Processing
Support batch control and safety instrumented systems (SIS) in ATEX/IECEx hazardous areas.


🛠️ Installation Guide

Pre-Installation Checks

  • ✓ Verify input voltage matches PS rating (120-230V AC or 110-300V DC)
  • ✓ Calculate total module current consumption (must be <10A)
  • ✓ Ensure adequate ventilation (50mm clearance above/below rack)
  • ✓ Confirm grounding infrastructure (PE connection required)

Installation Steps

  1. Power Down – De-energize all input power sources
  2. Mount PS – Insert PS 407 into Slot 1 of S7-400 rack, push until fully seated
  3. Lock Module – Engage locking mechanism to prevent accidental removal
  4. Wire Input – Connect L1, N (AC) or L+, M (DC) to input terminals, tighten to 0.5-0.6 Nm
  5. Ground Connection – Connect PE terminal to cabinet ground rail
  6. Power Up – Energize input, verify green ON LED illuminates
  7. Check Diagnostics – Verify DC OK LED is green (no FAULT LED)

🔧 Troubleshooting

LED Status Meaning Action
ON (green) Input power present Normal operation
DC OK (green) Output voltage stable Normal operation
FAULT (red) Overload or short circuit Check module current consumption, remove faulty modules
No LEDs No input power Verify input wiring, check circuit breaker
ON but no DC OK Output overload Reduce module count or upgrade to 20A PS

📊 PS 407 Model Comparison

Model Order Number Output Current Max Modules Best For
PS 407 5A 6ES7407-0KA02-0AA0 5A @ 5V DC Up to 9 modules Compact systems (UR1)
PS 407 10A 6ES7407-0DA00-0AA0 (This Product) 10A @ 5V DC Up to 18 modules Standard systems (UR2)
PS 407 20A 6ES7407-0KR02-0AA0 20A @ 5V DC Up to 36 modules Large systems, redundancy

🛡️ Authenticity Guarantee

⚠️ Counterfeit Power Supply Risks

Non-genuine power supplies can cause catastrophic failures:

  • 🔥 Voltage instability damaging CPUs and I/O modules
  • ⚡ Insufficient current causing intermittent system crashes
  • 💥 Fire hazards from substandard components
  • 🚫 Voided Siemens warranty on entire system
  • ⚖️ Regulatory non-compliance (UL, CE, ATEX)

✅ Industrial Control Hub Guarantee

  • 🔒 100% Genuine Siemens – Factory-sealed with holographic labels
  • 📜 Full Traceability – Serial numbers and manufacturing dates
  • 🌍 Authorized Distributor – Verify at Siemens Industry Mall
  • 🛡️ 24-Month Warranty – Global manufacturer warranty
  • 📦 Secure Packaging – ESD protection during shipping

📦 Package Contents

  • 1× Siemens 6ES7407-0DA00-0AA0 PS 407 power supply (10A)
  • Terminal block cover
  • Product documentation and certificate of conformity

Note: Input wiring and rack are NOT included. Order separately.


🤝 Technical Support

  • 📧 Power Budget Consultation – Email us your module list for sizing verification
  • 📚 Documentation – Manuals, wiring diagrams, and datasheets
  • 🎓 Training Resources – Power supply selection and installation guides
  • 🔄 30-Day Returns – Hassle-free returns if unused

❓ FAQ

Q: Can I use this PS with S7-300 systems?
A: No, PS 407 is exclusively for S7-400. S7-300 uses PS 307 series.

Q: What's the difference between 10A and 20A models?
A: 10A supports up to 18 modules, 20A supports up to 36 modules. Choose based on total current consumption.

Q: Can I mix AC and DC input power supplies in the same rack?
A: Yes, but both must have the same output current rating for redundancy.

Q: How do I calculate if 10A is sufficient?
A: Sum all module currents from datasheets, add 20% safety margin. If total <10A, this PS is adequate.

Q: Does this support 110V AC input?
A: Yes, input range is 120-230V AC. 110V is within tolerance.

Q: Can I hot-swap this power supply?
A: Only in redundant configurations with a second PS installed. Never in single-PS systems.