Skip to product information
1 of 9

Siemens 6DP1280-8AA TELEPERM XP FUM 280 Function Module

Siemens 6DP1280-8AA TELEPERM XP FUM 280 Function Module

  • Manufacturer: Siemens

  • Product No.: 6DP1280-8AA

  • Condition:1000 in stock

  • Product Type: TELEPERM XP FUM 280 Function Module

  • Product Origin: Germany

  • Payment: T/T, Western Union

  • Weight: 450g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Siemens 6DP1280-8AA TELEPERM XP FUM 280 Function Module

Product Overview

  • The Siemens 6DP1280-8AA is a TELEPERM XP FUM 280 Function Module designed for the TELEPERM XP automation system. This module supports continuous control tasks, handling two autonomous P-, PI-, PD-, or PID controllers or four analog controller outputs. It is used in industrial automation applications, such as chemical processing, power generation, and manufacturing, for precise control and signal acquisition of analog and binary signals. The module is suitable for non-redundant configurations.

Technical Specifications

  • The 6DP1280-8AA has the following specifications based on industry sources:
Specification Details
Model/Part Number 6DP1280-8AA
Manufacturer Siemens
Description TELEPERM XP FUM 280 Function Module for Continuous Controllers
Series TELEPERM XP
Function Two autonomous continuous P-, PI-, PD-, or PID controllers or four analog controller outputs with control algorithm in the AP
Analog Outputs: 0/4 to 20 mA
Analog Inputs: Four or two, 0/4 to 20 mA
Supply and acquisition of two analog values, 0/4 to 20 mA
Up to four limit values per analog input
Binary signal conditioning for travel limit switches
Input/Output Analog Outputs: 0/4 to 20 mA
Analog Inputs: 2 or 4, 0/4 to 20 mA
Binary Inputs: For travel limit switches
Power Supply 24 VDC (via TELEPERM XP rack backplane)
Power Consumption Approx. 10 W (estimated based on similar modules)
Environmental Specifications Ambient Temperature: 0°C to +60°C
Shock: 10 g ½ sine wave for 11 ms
Vibration: 1 mm peak to peak from 2 to 13.2 Hz; 0.7 g from 13.2 to 150 Hz
Relative Humidity: 5% to 95% non-condensing
Dimensions Approx. 280 mm (H) x 50 mm (W) x 280 mm (D)
Weight Approx. 0.45 kg
Mounting Plugs into TELEPERM XP rack
Certifications CE, UL

Additional Details

  • The 6DP1280-8AA includes the following additional information based on industry sources:
  • Function: Executes continuous control with two autonomous P-, PI-, PD-, or PID controllers or four analog outputs (0/4 to 20 mA) with algorithms in the automation processor; acquires and conditions two or four analog inputs (0/4 to 20 mA) with up to four limit values per input; supports binary signal conditioning for travel limit switches; designed for non-redundant control applications.

 

View full details

Product Description

Siemens 6DP1280-8AA TELEPERM XP FUM 280 Function Module

Product Overview

  • The Siemens 6DP1280-8AA is a TELEPERM XP FUM 280 Function Module designed for the TELEPERM XP automation system. This module supports continuous control tasks, handling two autonomous P-, PI-, PD-, or PID controllers or four analog controller outputs. It is used in industrial automation applications, such as chemical processing, power generation, and manufacturing, for precise control and signal acquisition of analog and binary signals. The module is suitable for non-redundant configurations.

Technical Specifications

  • The 6DP1280-8AA has the following specifications based on industry sources:
Specification Details
Model/Part Number 6DP1280-8AA
Manufacturer Siemens
Description TELEPERM XP FUM 280 Function Module for Continuous Controllers
Series TELEPERM XP
Function Two autonomous continuous P-, PI-, PD-, or PID controllers or four analog controller outputs with control algorithm in the AP
Analog Outputs: 0/4 to 20 mA
Analog Inputs: Four or two, 0/4 to 20 mA
Supply and acquisition of two analog values, 0/4 to 20 mA
Up to four limit values per analog input
Binary signal conditioning for travel limit switches
Input/Output Analog Outputs: 0/4 to 20 mA
Analog Inputs: 2 or 4, 0/4 to 20 mA
Binary Inputs: For travel limit switches
Power Supply 24 VDC (via TELEPERM XP rack backplane)
Power Consumption Approx. 10 W (estimated based on similar modules)
Environmental Specifications Ambient Temperature: 0°C to +60°C
Shock: 10 g ½ sine wave for 11 ms
Vibration: 1 mm peak to peak from 2 to 13.2 Hz; 0.7 g from 13.2 to 150 Hz
Relative Humidity: 5% to 95% non-condensing
Dimensions Approx. 280 mm (H) x 50 mm (W) x 280 mm (D)
Weight Approx. 0.45 kg
Mounting Plugs into TELEPERM XP rack
Certifications CE, UL

Additional Details

  • The 6DP1280-8AA includes the following additional information based on industry sources:
  • Function: Executes continuous control with two autonomous P-, PI-, PD-, or PID controllers or four analog outputs (0/4 to 20 mA) with algorithms in the automation processor; acquires and conditions two or four analog inputs (0/4 to 20 mA) with up to four limit values per input; supports binary signal conditioning for travel limit switches; designed for non-redundant control applications.

 