The ProSoft MVI56E-MCM is an advanced Modbus communication interface designed specifically for Allen-Bradley ControlLogix and CompactLogix platforms. This industrial-grade module bridges the gap between your Rockwell Automation PLC and Modbus-enabled devices, delivering reliable, high-speed data exchange across RTU, ASCII, and TCP/IP protocols.

Key Technical Specifications

  • Protocol Support: Modbus RTU, Modbus ASCII, Modbus TCP/IP (Master/Slave)
  • Platform Compatibility: Allen-Bradley ControlLogix 1756, CompactLogix 1769
  • Communication Ports: Dual RS-232/RS-485 serial ports + Ethernet 10/100 Mbps
  • Data Throughput: Up to 10,000 registers per scan cycle
  • Operating Temperature: 0°C to 60°C (32°F to 140°F)
  • Power Consumption: 5V DC @ 800mA (backplane powered)
  • Certifications: UL/cUL, CE, RoHS compliant

Industrial Applications

Process Automation: Integrate legacy Modbus instruments (flow meters, analyzers, transmitters) into modern ControlLogix SCADA systems without protocol conversion overhead.

Energy Management: Connect power monitoring equipment, smart meters, and energy analyzers to centralized PLC control for real-time consumption tracking and demand response.

Water & Wastewater: Interface with Modbus-based level sensors, pump controllers, and chemical dosing systems for municipal treatment facilities.

Manufacturing Execution: Link production line equipment, barcode scanners, and quality control devices to MES platforms via ControlLogix backbone.

Solution Advantages

The MVI56E-MCM eliminates the need for external protocol converters by embedding Modbus intelligence directly into your ControlLogix chassis. Its dual-port architecture allows simultaneous master/slave operations, enabling complex multi-drop networks with up to 247 Modbus devices per port. Built-in diagnostics and LED status indicators simplify commissioning and troubleshooting.

Advanced features include automatic baud rate detection, configurable timeout handling, and non-volatile memory for configuration retention during power cycles. The module's ladder logic interface provides seamless integration with RSLogix 5000/Studio 5000 programming environments.

Related Products

Product Description Link
ProSoft PLX31-EIP-MBS EtherNet/IP to Modbus Protocol Gateway View Product
ProSoft PLX31-EIP-MBS4 4-Port EtherNet/IP to Modbus Gateway View Product
Allen-Bradley 1756-L63A ControlLogix 5563 Processor Module View Product

© 2025 INDUSTRIAL CONTROL HUB. All rights reserved.
Original Source: https://www.indctrlhub.com
Contact: sales@indctrlhub.com | +0086 18359243191

View full details

Product Description

ProSoft MVI56E-MCM Modbus Communication Module

The ProSoft MVI56E-MCM is an advanced Modbus communication interface designed specifically for Allen-Bradley ControlLogix and CompactLogix platforms. This industrial-grade module bridges the gap between your Rockwell Automation PLC and Modbus-enabled devices, delivering reliable, high-speed data exchange across RTU, ASCII, and TCP/IP protocols.

Key Technical Specifications

  • Protocol Support: Modbus RTU, Modbus ASCII, Modbus TCP/IP (Master/Slave)
  • Platform Compatibility: Allen-Bradley ControlLogix 1756, CompactLogix 1769
  • Communication Ports: Dual RS-232/RS-485 serial ports + Ethernet 10/100 Mbps
  • Data Throughput: Up to 10,000 registers per scan cycle
  • Operating Temperature: 0°C to 60°C (32°F to 140°F)
  • Power Consumption: 5V DC @ 800mA (backplane powered)
  • Certifications: UL/cUL, CE, RoHS compliant

Industrial Applications

Process Automation: Integrate legacy Modbus instruments (flow meters, analyzers, transmitters) into modern ControlLogix SCADA systems without protocol conversion overhead.

Energy Management: Connect power monitoring equipment, smart meters, and energy analyzers to centralized PLC control for real-time consumption tracking and demand response.

Water & Wastewater: Interface with Modbus-based level sensors, pump controllers, and chemical dosing systems for municipal treatment facilities.

Manufacturing Execution: Link production line equipment, barcode scanners, and quality control devices to MES platforms via ControlLogix backbone.

Solution Advantages

The MVI56E-MCM eliminates the need for external protocol converters by embedding Modbus intelligence directly into your ControlLogix chassis. Its dual-port architecture allows simultaneous master/slave operations, enabling complex multi-drop networks with up to 247 Modbus devices per port. Built-in diagnostics and LED status indicators simplify commissioning and troubleshooting.

Advanced features include automatic baud rate detection, configurable timeout handling, and non-volatile memory for configuration retention during power cycles. The module's ladder logic interface provides seamless integration with RSLogix 5000/Studio 5000 programming environments.

Related Products

Product Description Link
ProSoft PLX31-EIP-MBS EtherNet/IP to Modbus Protocol Gateway View Product
ProSoft PLX31-EIP-MBS4 4-Port EtherNet/IP to Modbus Gateway View Product
Allen-Bradley 1756-L63A ControlLogix 5563 Processor Module View Product

© 2025 INDUSTRIAL CONTROL HUB. All rights reserved.
Original Source: https://www.indctrlhub.com
Contact: sales@indctrlhub.com | +0086 18359243191

Download PDF file here:

Click to Download PDF