Skip to product information
1 of 7

PHOENIX CONTACT QUINT-PS/1AC/24DC/40 Power Supply Unit

PHOENIX CONTACT QUINT-PS/1AC/24DC/40 Power Supply Unit

  • Manufacturer: PHOENIX CONTACT

  • Product No.: QUINT-PS/1AC/24DC/40

  • Condition:1000 in stock

  • Product Type: Power Supply Unit

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 3300g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Details


Field

Information

Manufacturer

Emerson

Model/Part Number

QUINT-PS/1AC/24DC/40

Description

Power Supply Unit


 



 

Technical Specifications



 

Input Data


Parameter

Specification

Nominal Input Voltage

100 V AC to 240 V AC

Input Voltage Range

85 V AC to 264 V AC90 V DC to 300 V DC (UL: ≤250 V DC)

Short-term Input Voltage

300 V AC

AC Frequency Range

45 Hz to 65 Hz

DC Frequency

0 Hz

Current Consumption

8.8 A (120 V AC)4.6 A (230 V AC)9.5 A (110 V DC)4.7 A (220 V DC)

Inrush Current Limitation

< 15 A (typical)

I²t

< 1.7 A²s

Power Failure Bypass

> 35 ms (120/230 V AC)

Typical Response Time

< 0.7 s

Input Protection

Varistor & gas-filled surge arrester

Integrated Input Fuse

20 A (slow-blow, internal)

Recommended External Fuses

16 A–20 A (AC: B, C, D, K curves)

Discharge Current to PE

< 3.5 mA

 

Output Data


Parameter

Specification

Nominal Output Voltage

24 V DC ±1%

Output Voltage Range

18 V DC to 29.5 V DC

Output Current

40 A (-25°C to 60°C)45 A (BOOST mode to 40°C)215 A (SFB for 12 ms)

Overcurrent Protection

Magnetic Fuse Tripping: B2–B25, C2–C13

Efficiency

> 92% (at 230 V AC, nominal load)

Rise Time

< 0.1 s (10% to 90%)

Residual Ripple

< 30 mVPP

Parallel Operation

Yes (redundancy/increased capacity)

Series Operation

Yes

Output Surge Protection

< 35 V DC

Reverse Feed Resistance

Max 35 V DC

 

Status & Monitoring


Feature

Specification

DC OK (Active)

18–24 V DC, ≤ 20 mA (short-circuit protected), green LED

DC OK (Floating)

Relay Contact:30 V AC / 0.5 A24 V DC / 1 A

BOOST Mode Status

LED “BOOST” (yellow) active above IN threshold


 



 

General Data


Parameter

Specification

Insulation (Input/Output)

4 kV AC (type test), 2 kV AC (routine test)

Insulation (Input/PE)

3.5 kV AC (type), 2 kV AC (routine)

Insulation (Output/PE)

500 V DC

Degree of Protection

IP20

Protection Class

I

MTBF

> 530,000 h (40°C), > 900,000 h (25°C)

Housing

Aluminum sides, galvanized steel hood (chrome-free)

Dimensions (Standard)

180 mm (W) × 130 mm (H) × 125 mm (D)

Dimensions (90° Turned)

122 mm (W) × 130 mm (H) × 183 mm (D)

Weight

3.3 kg


 

View full details

Product Description

Product Details


Field

Information

Manufacturer

Emerson

Model/Part Number

QUINT-PS/1AC/24DC/40

Description

Power Supply Unit


 



 

Technical Specifications



 

Input Data


Parameter

Specification

Nominal Input Voltage

100 V AC to 240 V AC

Input Voltage Range

85 V AC to 264 V AC90 V DC to 300 V DC (UL: ≤250 V DC)

Short-term Input Voltage

300 V AC

AC Frequency Range

45 Hz to 65 Hz

DC Frequency

0 Hz

Current Consumption

8.8 A (120 V AC)4.6 A (230 V AC)9.5 A (110 V DC)4.7 A (220 V DC)

Inrush Current Limitation

< 15 A (typical)

I²t

< 1.7 A²s

Power Failure Bypass

> 35 ms (120/230 V AC)

Typical Response Time

< 0.7 s

Input Protection

Varistor & gas-filled surge arrester

Integrated Input Fuse

20 A (slow-blow, internal)

Recommended External Fuses

16 A–20 A (AC: B, C, D, K curves)

Discharge Current to PE

< 3.5 mA

 

Output Data


Parameter

Specification

Nominal Output Voltage

24 V DC ±1%

Output Voltage Range

18 V DC to 29.5 V DC

Output Current

40 A (-25°C to 60°C)45 A (BOOST mode to 40°C)215 A (SFB for 12 ms)

Overcurrent Protection

Magnetic Fuse Tripping: B2–B25, C2–C13

Efficiency

> 92% (at 230 V AC, nominal load)

Rise Time

< 0.1 s (10% to 90%)

Residual Ripple

< 30 mVPP

Parallel Operation

Yes (redundancy/increased capacity)

Series Operation

Yes

Output Surge Protection

< 35 V DC

Reverse Feed Resistance

Max 35 V DC

 

Status & Monitoring


Feature

Specification

DC OK (Active)

18–24 V DC, ≤ 20 mA (short-circuit protected), green LED

DC OK (Floating)

Relay Contact:30 V AC / 0.5 A24 V DC / 1 A

BOOST Mode Status

LED “BOOST” (yellow) active above IN threshold


 



 

General Data


Parameter

Specification

Insulation (Input/Output)

4 kV AC (type test), 2 kV AC (routine test)

Insulation (Input/PE)

3.5 kV AC (type), 2 kV AC (routine)

Insulation (Output/PE)

500 V DC

Degree of Protection

IP20

Protection Class

I

MTBF

> 530,000 h (40°C), > 900,000 h (25°C)

Housing

Aluminum sides, galvanized steel hood (chrome-free)

Dimensions (Standard)

180 mm (W) × 130 mm (H) × 125 mm (D)

Dimensions (90° Turned)

122 mm (W) × 130 mm (H) × 183 mm (D)

Weight

3.3 kg


 

Download PDF file here:

Click to Download PDF

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%