Skip to product information
1 of 3

Pepperl+Fuchs F2D0-FB-EX4.CG FieldBarrier

Pepperl+Fuchs F2D0-FB-EX4.CG FieldBarrier

  • Manufacturer: P+F

  • Product No.: F2D0-FB-EX4.CG

  • Condition:1000 in stock

  • Product Type: FieldBarrier

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 3350g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Pepperl+Fuchs F2D0-FB-EX4.CG FieldBarrier

Product Overview

  • The Pepperl+Fuchs F2D0-FB-EX4.CG is a FieldBarrier® designed for hazardous environments, providing a reliable interface between field devices and control systems in safety-critical applications. Part of the FieldConnex series for FOUNDATION Fieldbus H1 and PROFIBUS PA, this device coupler connects up to four intrinsically safe field instruments, ensuring robust communication in Zone 1/Div. 2 areas. It is widely used in industries such as oil and gas, chemical, and process automation, offering explosion protection and fault-tolerant operation.

Technical Specifications

  • The F2D0-FB-EX4.CG has the following specifications based on documentation from Pepperl+Fuchs and industry sources:
Specification Details
Model/Part Number F2D0-FB-EX4.CG (PN: 127072)
Manufacturer Pepperl+Fuchs
Description FieldBarrier (Fieldbus Device Coupler)
Outputs 4 intrinsically safe outputs (Ex ia/Ex ib)
Supported Protocols FOUNDATION Fieldbus H1, PROFIBUS PA
Intrinsic Safety Standards FISCO (Fieldbus Intrinsically Safe Concept), Entity
Input Voltage 16–32 VDC
Short-Circuit Protection Current limitation at each output
Housing Sturdy cast aluminum (F2 type)
Dimensions Width: 240 mm
Height: 150 mm
Depth: 258 mm
Weight Approx. 3.35 kg
Operating Temperature -30°C to +70°C (-22°F to +158°F)
Installation Zone 1/Div. 2, instruments in Zone 0–1/Div. 1
Indicators LEDs for operation, communication, and fault status

Additional Details

  • The F2D0-FB-EX4.CG includes the following additional information based on documentation from Pepperl+Fuchs, Kempston Controls, and other industry sources:
  • Function: Connects up to four field devices with intrinsically safe outputs (Ex ia/Ex ib), providing short-circuit current limitation to maintain segment operation during faults or hot work; supports high trunk power for maximum cable lengths and device counts in hazardous areas.

 

View full details

Product Description

Pepperl+Fuchs F2D0-FB-EX4.CG FieldBarrier

Product Overview

  • The Pepperl+Fuchs F2D0-FB-EX4.CG is a FieldBarrier® designed for hazardous environments, providing a reliable interface between field devices and control systems in safety-critical applications. Part of the FieldConnex series for FOUNDATION Fieldbus H1 and PROFIBUS PA, this device coupler connects up to four intrinsically safe field instruments, ensuring robust communication in Zone 1/Div. 2 areas. It is widely used in industries such as oil and gas, chemical, and process automation, offering explosion protection and fault-tolerant operation.

Technical Specifications

  • The F2D0-FB-EX4.CG has the following specifications based on documentation from Pepperl+Fuchs and industry sources:
Specification Details
Model/Part Number F2D0-FB-EX4.CG (PN: 127072)
Manufacturer Pepperl+Fuchs
Description FieldBarrier (Fieldbus Device Coupler)
Outputs 4 intrinsically safe outputs (Ex ia/Ex ib)
Supported Protocols FOUNDATION Fieldbus H1, PROFIBUS PA
Intrinsic Safety Standards FISCO (Fieldbus Intrinsically Safe Concept), Entity
Input Voltage 16–32 VDC
Short-Circuit Protection Current limitation at each output
Housing Sturdy cast aluminum (F2 type)
Dimensions Width: 240 mm
Height: 150 mm
Depth: 258 mm
Weight Approx. 3.35 kg
Operating Temperature -30°C to +70°C (-22°F to +158°F)
Installation Zone 1/Div. 2, instruments in Zone 0–1/Div. 1
Indicators LEDs for operation, communication, and fault status

Additional Details

  • The F2D0-FB-EX4.CG includes the following additional information based on documentation from Pepperl+Fuchs, Kempston Controls, and other industry sources:
  • Function: Connects up to four field devices with intrinsically safe outputs (Ex ia/Ex ib), providing short-circuit current limitation to maintain segment operation during faults or hot work; supports high trunk power for maximum cable lengths and device counts in hazardous areas.

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)