| Protocol Support |
CANopen (DS-301, DS-402 device profiles), up to 1 Mbps baud rate |
| Interfaces |
CAN bus connector, fiber optic link for drive connection |
| Node ID Configuration |
Configurable via DIP switches or software |
| Error Handling |
CANopen error register, fault codes (e.g., overcurrent, short circuit) |
| Power Supply |
24 V DC (from drive system) |
| Power Consumption |
3 W maximum |
| Operating Temperature Range |
-15°C to +55°C |
| Mounting |
Internal slot mounting in drive cabinet |
| Dimensions |
100 mm x 80 mm x 20 mm (L x W x H) approximate |
| Weight |
0.2 kg |
| Standards Compliance |
IEC 61158, CANopen CiA 301/402, CE marked |