Skip to product information
1 of 6

Honeywell 04230-A-1001 Handheld Interrogator SHC-1

Honeywell 04230-A-1001 Handheld Interrogator SHC-1

  • Manufacturer: Honeywell

  • Product No.: 04230-A-1001

  • Condition:1000 in stock

  • Product Type: Handheld Interrogator SHC-1

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Overview

Field Details
Manufacturer Honeywell Analytics
Part Number 04230-A-1001
Product Type Handheld Interrogator SHC-1
Function Configures, aligns, calibrates, and diagnoses Searchline Excel, Optima, and Optima Plus gas detectors
Compatibility Searchline Excel, Searchline Optima, Searchline Optima Plus
Associated Document MAN0530 Issue 12 - 10/12 (Searchline Excel Technical Handbook)

Functional Specifications

Feature Specification
Interface Menu-style interface via RS485 serial link for commissioning, configuration, and diagnostics
Connection Method Connects to receiver via DX/DVC100(M) series termination units or junction box with SHC Protection Device
Software Version 4V0
Key Functions - System self-test
- Alignment (Instrument Assisted Alignment, IAA)
- Initialization
- Time and date setting
- Zero calibration
- Force 4-20mA output
- Return to normal 4-20mA output
- Display calibration and configuration status
- Display active faults and warnings
- Soft reset
Alignment Process - Displays SIG (current signal) and TGT (target signal) bar graphs
- Ensures SIG ≥ TGT (minimum 70% of expected signal for path length)
- Supports bayonet-style Trident and latch-style telescopes
Calibration Inhibits 4-20mA output during zero calibration; requires no gas in beam path
Output Control Adjustable 4-20mA output from 1 mA to 21 mA in 0.1 mA steps
Configuration Display Shows gas, user, and installation parameters
Operating Modes Toggles between Excel, Optima, and Optima Plus modes

Physical Specifications

Feature Specification
Dimensions Length: 190 mm (7.48 in)
Width: 80 mm (3.15 in)
Depth: 40 mm (1.57 in)
Weight 0.5 kg (1.1 lb)
Material Stainless Steel ANSI 316

Environmental Specifications

Parameter Specification
Operating Temperature 0°C to +40°C (+32°F to +104°F); DMT evaluated: -25°C to +55°C (-13°F to +131°F)
Storage Temperature -10°C to +40°C (+14°F to +104°F)
Operating Humidity 0 to 99% RH (non-condensing)

Electrical Specifications

Feature Specification
Power Battery-powered; auto power-off after 5 minutes of non-use (disabled during configuration changes)
Fast Power-Off Press ↓ and ESC simultaneously

Regulatory Compliance

Certification Type Details
ATEX & IECEx ATEX: Baseefa03ATEX0073
IECEx: BAS 09.0120
II 2G Ex ia IIC T4 Gb (Tamb -40°C to +40°C)
Standards EN60079-0:2012, EN60079-11:2012
IEC60079-0:2011, IEC60079-11:2011

Ordering Information

Field Details
Part Number 04230-A-1001: Handheld Interrogator ATEX Certified (4V0 software) for Optima, Optima Plus, and Excel
Related Parts - 2104B2351: UL Certified Handheld Interrogator
- 2104B2354: CSA/FM Certified Handheld Interrogator
- 2108B1455: Handheld EEPROM upgrade (4V0)
- 04320-A-1025: SHC Protection Device Module and Lead
- 2104B6250: SHC Calibrator Connector System 10m
Accessories Included in alignment kits 

 

View full details

Product Description

Product Overview

Field Details
Manufacturer Honeywell Analytics
Part Number 04230-A-1001
Product Type Handheld Interrogator SHC-1
Function Configures, aligns, calibrates, and diagnoses Searchline Excel, Optima, and Optima Plus gas detectors
Compatibility Searchline Excel, Searchline Optima, Searchline Optima Plus
Associated Document MAN0530 Issue 12 - 10/12 (Searchline Excel Technical Handbook)

Functional Specifications

Feature Specification
Interface Menu-style interface via RS485 serial link for commissioning, configuration, and diagnostics
Connection Method Connects to receiver via DX/DVC100(M) series termination units or junction box with SHC Protection Device
Software Version 4V0
Key Functions - System self-test
- Alignment (Instrument Assisted Alignment, IAA)
- Initialization
- Time and date setting
- Zero calibration
- Force 4-20mA output
- Return to normal 4-20mA output
- Display calibration and configuration status
- Display active faults and warnings
- Soft reset
Alignment Process - Displays SIG (current signal) and TGT (target signal) bar graphs
- Ensures SIG ≥ TGT (minimum 70% of expected signal for path length)
- Supports bayonet-style Trident and latch-style telescopes
Calibration Inhibits 4-20mA output during zero calibration; requires no gas in beam path
Output Control Adjustable 4-20mA output from 1 mA to 21 mA in 0.1 mA steps
Configuration Display Shows gas, user, and installation parameters
Operating Modes Toggles between Excel, Optima, and Optima Plus modes

Physical Specifications

Feature Specification
Dimensions Length: 190 mm (7.48 in)
Width: 80 mm (3.15 in)
Depth: 40 mm (1.57 in)
Weight 0.5 kg (1.1 lb)
Material Stainless Steel ANSI 316

Environmental Specifications

Parameter Specification
Operating Temperature 0°C to +40°C (+32°F to +104°F); DMT evaluated: -25°C to +55°C (-13°F to +131°F)
Storage Temperature -10°C to +40°C (+14°F to +104°F)
Operating Humidity 0 to 99% RH (non-condensing)

Electrical Specifications

Feature Specification
Power Battery-powered; auto power-off after 5 minutes of non-use (disabled during configuration changes)
Fast Power-Off Press ↓ and ESC simultaneously

Regulatory Compliance

Certification Type Details
ATEX & IECEx ATEX: Baseefa03ATEX0073
IECEx: BAS 09.0120
II 2G Ex ia IIC T4 Gb (Tamb -40°C to +40°C)
Standards EN60079-0:2012, EN60079-11:2012
IEC60079-0:2011, IEC60079-11:2011

Ordering Information

Field Details
Part Number 04230-A-1001: Handheld Interrogator ATEX Certified (4V0 software) for Optima, Optima Plus, and Excel
Related Parts - 2104B2351: UL Certified Handheld Interrogator
- 2104B2354: CSA/FM Certified Handheld Interrogator
- 2108B1455: Handheld EEPROM upgrade (4V0)
- 04320-A-1025: SHC Protection Device Module and Lead
- 2104B6250: SHC Calibrator Connector System 10m
Accessories Included in alignment kits 

 

Download PDF file here:

Click to Download PDF

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)