Skip to product information
1 of 1

GE T60G01HCHF8HH67M8FP6DU6DW6C Multilin Transformer Protection Relay

GE T60G01HCHF8HH67M8FP6DU6DW6C Multilin Transformer Protection Relay

  • Manufacturer: General Electric

  • Product No.: T60G01HCHF8HH67M8FP6DU6DW6C

  • Condition:1000 in stock

  • Product Type: Multilin Transformer Protection Relay

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 4500g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

General Electric T60G01HCHF8HH67M8FP6DU6DW6C Multilin Transformer Protection Relay

Product Overview

  • Description: The General Electric T60G01HCHF8HH67M8FP6DU6DW6C is a Multilin T60 transformer protection relay designed for advanced protection, control, and monitoring of power transformers in utility and industrial applications._

Technical Specifications

Specification Details
Manufacturer General Electric
Series Multilin T60
Model/Part Number T60G01HCHF8HH67M8FP6DU6DW6C
Model Type Transformer Protection Relay
Function Protection, control, and monitoring of power transformers
Display Graphical LCD (HCH: Enhanced front panel with large display)
Inputs 8 CT inputs (F8H: 8 CTs, high sensitivity), 4 VT inputs, multiple digital inputs (configurable)
Outputs 6 Form-A relay outputs (H67: 6 outputs), 2 analog outputs (configurable)
Communication Interfaces Ethernet, Modbus TCP/IP, DNP 3.0, IEC 61850 (M8F: Enhanced communications), RS485
Signal Conditioning Internal analog-to-digital conversion, differential protection algorithms
Accuracy ±0.5% for current/voltage measurements (typical)
Protection Features Transformer differential (87T), restricted earth fault (REF), phase/ground overcurrent (50/51, 50N/51N), over/under voltage (59/27), over/under frequency (81O/U), thermal overload (49), breaker failure, RTD temperature monitoring (P6D: 6 RTD inputs)
Redundancy Not applicable (single device, supports redundant power supply)
Diagnostics Event recording (up to 1024 events), waveform capture, fault diagnostics, self-test
Compatibility Integrates with SCADA systems, Multilin EnerVista software
Power Supply 125_250 VDC or 100_240 VAC (G01: High voltage power supply)
Power Consumption 15 W typical, 25 W max
Environmental Specifications Operating Temperature: -40°C to +60°C
Storage Temperature: -40°C to +80°C
Relative Humidity: 5% to 95% non-condensing
Enclosure IP40 (front), IP20 (rear, mounted in panel)
Dimensions Approx. 178 mm (H) x 146 mm (W) x 203 mm (D)
Weight 4.5 kg (approx.)
Mounting Panel mount, 19-inch rack compatible
Certifications CE, UL, cULus, IEC 60255, RoHS

_

View full details

Product Description

General Electric T60G01HCHF8HH67M8FP6DU6DW6C Multilin Transformer Protection Relay

Product Overview

  • Description: The General Electric T60G01HCHF8HH67M8FP6DU6DW6C is a Multilin T60 transformer protection relay designed for advanced protection, control, and monitoring of power transformers in utility and industrial applications._

Technical Specifications

Specification Details
Manufacturer General Electric
Series Multilin T60
Model/Part Number T60G01HCHF8HH67M8FP6DU6DW6C
Model Type Transformer Protection Relay
Function Protection, control, and monitoring of power transformers
Display Graphical LCD (HCH: Enhanced front panel with large display)
Inputs 8 CT inputs (F8H: 8 CTs, high sensitivity), 4 VT inputs, multiple digital inputs (configurable)
Outputs 6 Form-A relay outputs (H67: 6 outputs), 2 analog outputs (configurable)
Communication Interfaces Ethernet, Modbus TCP/IP, DNP 3.0, IEC 61850 (M8F: Enhanced communications), RS485
Signal Conditioning Internal analog-to-digital conversion, differential protection algorithms
Accuracy ±0.5% for current/voltage measurements (typical)
Protection Features Transformer differential (87T), restricted earth fault (REF), phase/ground overcurrent (50/51, 50N/51N), over/under voltage (59/27), over/under frequency (81O/U), thermal overload (49), breaker failure, RTD temperature monitoring (P6D: 6 RTD inputs)
Redundancy Not applicable (single device, supports redundant power supply)
Diagnostics Event recording (up to 1024 events), waveform capture, fault diagnostics, self-test
Compatibility Integrates with SCADA systems, Multilin EnerVista software
Power Supply 125_250 VDC or 100_240 VAC (G01: High voltage power supply)
Power Consumption 15 W typical, 25 W max
Environmental Specifications Operating Temperature: -40°C to +60°C
Storage Temperature: -40°C to +80°C
Relative Humidity: 5% to 95% non-condensing
Enclosure IP40 (front), IP20 (rear, mounted in panel)
Dimensions Approx. 178 mm (H) x 146 mm (W) x 203 mm (D)
Weight 4.5 kg (approx.)
Mounting Panel mount, 19-inch rack compatible
Certifications CE, UL, cULus, IEC 60255, RoHS

_