Skip to product information
1 of 3

GE T60-N11-AKH-F8L-H6N-M8N-P6P-U6P-W6P Multilin Transformer Protection Relay

GE T60-N11-AKH-F8L-H6N-M8N-P6P-U6P-W6P Multilin Transformer Protection Relay

  • Manufacturer: General Electric

  • Product No.: T60-N11-AKH-F8L-H6N-M8N-P6P-U6P-W6P

  • Condition:1000 in stock

  • Product Type: Multilin Transformer Protection Relay

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 7500g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

General Electric T60-N11-AKH-F8L-H6N-M8N-P6P-U6P-W6P Multilin Transformer Protection Relay

  • Manufacturer: General Electric (now under GE Vernova)
  • Series: Multilin T60
  • Model/Part Number: T60-N11-AKH-F8L-H6N-M8N-P6P-U6P-W6P
  • Description: Transformer Protection Relay for power system transformer management in Multilin T60 series

Overview

The General Electric T60-N11-AKH-F8L-H6N-M8N-P6P-U6P-W6P is a Transformer Protection Relay from the Multilin T60 series, manufactured by GE and now managed by GE Vernova. Built on the Universal Relay (UR) platform, it provides comprehensive protection, control, and monitoring for power transformers in medium to large-scale power systems. It supports advanced transformer protection, including differential, overcurrent, and restricted earth fault, and is used in power generation, transmission, and distribution applications.

Technical Specifications

Specification Details
Model T60-N11-AKH-F8L-H6P-M8N-P6P-U6P-W6P
Series Multilin T60
Type Transformer Protection Relay
Function Protection, metering, and control for power transformers
CPU Type N11: 2 x 10/100Base-TX Ethernet, 2 x 100Base-FX multimode ST, advanced protocols (e.g., IEC 61850)
Power Supply 125–250 VDC, 100–240 VAC @ 50/60 Hz (AKH)
CT/VT Inputs F8L: 8 inputs (4 CT, 4 VT, standard configuration with enhanced diagnostics)
Digital I/O H6N: 6 Form-A outputs (no monitoring), 8 digital inputs
Contact Outputs M8N: 4 Form-A (no monitoring), 4 Form-C, 8 digital inputs
RTD Inputs P6P: 6 RTD inputs (100 Ω Platinum, Nickel, Copper)
Analog Inputs U6P: 4 analog inputs (0–1 mA, 0–20 mA, 4–20 mA)
Transceiver W6P: 820 nm, multimode fiber, LED, 2 channels
Protection Features Transformer differential (87T), restricted earth fault (REF), overcurrent (50/51, 50N, 51N), over/under voltage (59/27), over/under frequency (81O/U), thermal overload (49), breaker failure
Metering Current, voltage, power, energy, frequency, harmonics, temperature
Event Recording Up to 1024 events with time and date stamping
Communication Protocols IEC 61850, DNP3, Modbus RTU/TCP, IEC 60870-5-104
Communication Ports 2 x RJ-45 Ethernet, 2 x ST fiber, RS485, front RS232 (9600–115,200 baud)
Connectors Terminal blocks for I/O and CT/VT, RJ-45/ST for communication, RS232 DB-9
Display Enhanced front panel with 16x40 character LCD, 16-key keypad
Environmental Protection Conformal coating for harsh environments
Operating Temperature -40°C to +60°C (-40°F to +140°F)
Storage Temperature -40°C to +80°C (-40°F to +176°F)
Relative Humidity Up to 95% (non-condensing)
Dimensions Approx. 48.3 cm x 13.3 cm x 28.5 cm (19.0 x 5.2 x 11.2 in)
Weight Approx. 7.5 kg (16.5 lbs)
Mounting Horizontal 19-inch rack mount, draw-out case
Certifications CE, UL, CSA, IEC, IEEE C37.91 compliant
Compatibility Multilin Universal Relay platform, EnerVista UR software
Manual GEK-113190 (Multilin T60 Manual)

 

View full details

Product Description

General Electric T60-N11-AKH-F8L-H6N-M8N-P6P-U6P-W6P Multilin Transformer Protection Relay

  • Manufacturer: General Electric (now under GE Vernova)
  • Series: Multilin T60
  • Model/Part Number: T60-N11-AKH-F8L-H6N-M8N-P6P-U6P-W6P
  • Description: Transformer Protection Relay for power system transformer management in Multilin T60 series

Overview

The General Electric T60-N11-AKH-F8L-H6N-M8N-P6P-U6P-W6P is a Transformer Protection Relay from the Multilin T60 series, manufactured by GE and now managed by GE Vernova. Built on the Universal Relay (UR) platform, it provides comprehensive protection, control, and monitoring for power transformers in medium to large-scale power systems. It supports advanced transformer protection, including differential, overcurrent, and restricted earth fault, and is used in power generation, transmission, and distribution applications.

Technical Specifications

Specification Details
Model T60-N11-AKH-F8L-H6P-M8N-P6P-U6P-W6P
Series Multilin T60
Type Transformer Protection Relay
Function Protection, metering, and control for power transformers
CPU Type N11: 2 x 10/100Base-TX Ethernet, 2 x 100Base-FX multimode ST, advanced protocols (e.g., IEC 61850)
Power Supply 125–250 VDC, 100–240 VAC @ 50/60 Hz (AKH)
CT/VT Inputs F8L: 8 inputs (4 CT, 4 VT, standard configuration with enhanced diagnostics)
Digital I/O H6N: 6 Form-A outputs (no monitoring), 8 digital inputs
Contact Outputs M8N: 4 Form-A (no monitoring), 4 Form-C, 8 digital inputs
RTD Inputs P6P: 6 RTD inputs (100 Ω Platinum, Nickel, Copper)
Analog Inputs U6P: 4 analog inputs (0–1 mA, 0–20 mA, 4–20 mA)
Transceiver W6P: 820 nm, multimode fiber, LED, 2 channels
Protection Features Transformer differential (87T), restricted earth fault (REF), overcurrent (50/51, 50N, 51N), over/under voltage (59/27), over/under frequency (81O/U), thermal overload (49), breaker failure
Metering Current, voltage, power, energy, frequency, harmonics, temperature
Event Recording Up to 1024 events with time and date stamping
Communication Protocols IEC 61850, DNP3, Modbus RTU/TCP, IEC 60870-5-104
Communication Ports 2 x RJ-45 Ethernet, 2 x ST fiber, RS485, front RS232 (9600–115,200 baud)
Connectors Terminal blocks for I/O and CT/VT, RJ-45/ST for communication, RS232 DB-9
Display Enhanced front panel with 16x40 character LCD, 16-key keypad
Environmental Protection Conformal coating for harsh environments
Operating Temperature -40°C to +60°C (-40°F to +140°F)
Storage Temperature -40°C to +80°C (-40°F to +176°F)
Relative Humidity Up to 95% (non-condensing)
Dimensions Approx. 48.3 cm x 13.3 cm x 28.5 cm (19.0 x 5.2 x 11.2 in)
Weight Approx. 7.5 kg (16.5 lbs)
Mounting Horizontal 19-inch rack mount, draw-out case
Certifications CE, UL, CSA, IEC, IEEE C37.91 compliant
Compatibility Multilin Universal Relay platform, EnerVista UR software
Manual GEK-113190 (Multilin T60 Manual)

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)