Skip to product information
1 of 4

GE G30-V03-HKH-F8L-H6D-M8L-P6X-U6T-WXX Generator Protection System

GE G30-V03-HKH-F8L-H6D-M8L-P6X-U6T-WXX Generator Protection System

  • Manufacturer: General Electric

  • Product No.: G30-V03-HKH-F8L-H6D-M8L-P6X-U6T-WXX

  • Condition:1000 in stock

  • Product Type: Generator Protection System

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 10000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

General Electric G30-V03-HKH-F8L-H6D-M8L-P6X-U6T-WXX Generator Protection System

  • Manufacturer: General Electric
  • Series: Multilin UR (Universal Relay)
  • Model/Part Number: G30-V03-HKH-F8L-H6D-M8L-P6X-U6T-WXX
  • Description: Generator Protection System for protection, control, and monitoring of small to medium-sized generators

Overview

  • The General Electric Multilin G30-V03-HKH-F8L-H6D-M8L-P6X-U6T-WXX is a microprocessor-based Generator Protection System from the UR (Universal Relay) series, designed for comprehensive protection, control, and monitoring of small to medium-sized synchronous or induction generators. It is suitable for industrial and utility applications, offering advanced features like differential protection and IEC 61850 compliance.

Technical Specifications

Specification Details
Model G30-V03-HKH-F8L-H6D-M8L-P6X-U6T-WXX
Series Multilin UR
Type Generator Protection Relay (Microprocessor-Based)
CPU Type V, Version 03 (V03): RS485 + 3 100BaseT Ethernet, SFP with RJ45
Mounting Horizontal, 19-inch rack (HKH)
Power Supply High Voltage (H): 125–250 VDC, 100–240 VAC, 50/60 Hz
CT/VT Inputs (Slot F) 8L: Standard 4 CT/4 VT with enhanced diagnostics
Digital I/O (Slot H) 6D: 8 digital inputs, 4 Form-C outputs
Digital I/O (Slot M) 8L: 8 contact inputs
CT/VT Inputs (Slot P) 6X: No CT/VT module
Digital I/O (Slot U) 6T: 2 Form-A (current with voltage monitor), 15 inputs
Digital I/O (Slot W) XX: No module
Protection Features Generator differential, stator ground fault, loss of excitation, overexcitation, reverse power, over/under voltage, over/under frequency, inadvertent energization, thermal overload
Metering Capabilities Current, voltage, power, energy, frequency, harmonics, synchrophasors
Communication Ports Three 100Mbps Ethernet (fiber/copper), RS485, USB; Protocols: IEC 61850, Modbus TCP/IP, DNP3.0, IEC 60870-5-104, IEEE 1588
Programmable Logic FlexLogic for customized control schemes
Display Enhanced front panel with LCD, programmable pushbuttons, LEDs
Event Recording Sequence of events, oscillography, data logger
Operating Temperature -40°C to +60°C (-40°F to +140°F)
Storage Temperature -40°C to +80°C (-40°F to +176°F)
Weight 10 kg (22 lbs)
Dimensions 48.3 x 13.3 x 28.2 cm (19 x 5.2 x 11.1 in)
Mounting Horizontal rack-mount, metal case
Certifications CE, CSA, UL, IEC
Software Compatibility EnerVista UR for setup, monitoring, and analysis

 

View full details

Product Description

General Electric G30-V03-HKH-F8L-H6D-M8L-P6X-U6T-WXX Generator Protection System

  • Manufacturer: General Electric
  • Series: Multilin UR (Universal Relay)
  • Model/Part Number: G30-V03-HKH-F8L-H6D-M8L-P6X-U6T-WXX
  • Description: Generator Protection System for protection, control, and monitoring of small to medium-sized generators

Overview

  • The General Electric Multilin G30-V03-HKH-F8L-H6D-M8L-P6X-U6T-WXX is a microprocessor-based Generator Protection System from the UR (Universal Relay) series, designed for comprehensive protection, control, and monitoring of small to medium-sized synchronous or induction generators. It is suitable for industrial and utility applications, offering advanced features like differential protection and IEC 61850 compliance.

Technical Specifications

Specification Details
Model G30-V03-HKH-F8L-H6D-M8L-P6X-U6T-WXX
Series Multilin UR
Type Generator Protection Relay (Microprocessor-Based)
CPU Type V, Version 03 (V03): RS485 + 3 100BaseT Ethernet, SFP with RJ45
Mounting Horizontal, 19-inch rack (HKH)
Power Supply High Voltage (H): 125–250 VDC, 100–240 VAC, 50/60 Hz
CT/VT Inputs (Slot F) 8L: Standard 4 CT/4 VT with enhanced diagnostics
Digital I/O (Slot H) 6D: 8 digital inputs, 4 Form-C outputs
Digital I/O (Slot M) 8L: 8 contact inputs
CT/VT Inputs (Slot P) 6X: No CT/VT module
Digital I/O (Slot U) 6T: 2 Form-A (current with voltage monitor), 15 inputs
Digital I/O (Slot W) XX: No module
Protection Features Generator differential, stator ground fault, loss of excitation, overexcitation, reverse power, over/under voltage, over/under frequency, inadvertent energization, thermal overload
Metering Capabilities Current, voltage, power, energy, frequency, harmonics, synchrophasors
Communication Ports Three 100Mbps Ethernet (fiber/copper), RS485, USB; Protocols: IEC 61850, Modbus TCP/IP, DNP3.0, IEC 60870-5-104, IEEE 1588
Programmable Logic FlexLogic for customized control schemes
Display Enhanced front panel with LCD, programmable pushbuttons, LEDs
Event Recording Sequence of events, oscillography, data logger
Operating Temperature -40°C to +60°C (-40°F to +140°F)
Storage Temperature -40°C to +80°C (-40°F to +176°F)
Weight 10 kg (22 lbs)
Dimensions 48.3 x 13.3 x 28.2 cm (19 x 5.2 x 11.1 in)
Mounting Horizontal rack-mount, metal case
Certifications CE, CSA, UL, IEC
Software Compatibility EnerVista UR for setup, monitoring, and analysis

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)