Product Overview



Parameter Details
Part Number 750-P5-G5-S5-HI-A20-R-T-H
Product Name 750/760 Series Feeder Management Relay
Application Protection and control of distribution feeders, backup for transformers, power lines, and buses in industrial and utility systems
Compatibility Integrates with GE Multilin 750/760 series relays, EnerVista 750 software, and 19-inch rack panels
Function Provides overcurrent protection, metering, event recording, and enhanced communication for feeder management

Functional Specifications



Parameter Details
Phase Current Inputs 5 A (4 phase CT inputs)
Ground Current Inputs 5 A (sensitive ground CT input, G5 in part number)
Zero Sequence Current 5 A (standard ground CT input, S5 in part number)
Control Power Supply 88-300 V DC or 70-265 V AC (48-62 Hz) (HI in part number, high range)
Ethernet Interface 10Base-T with RJ45 port; enhanced communication (T in part number)
Communication Ports RS232 front panel for EnerVista software; rear RS485 for Modbus; supports Modbus TCP/IP (T in part number)
Analog Outputs 2 analog outputs (0-20 mA or 4-20 mA, A20 in part number)
Output Relays 8 electromechanical (5 general-purpose, 3 form-C trip contacts)
Logic Inputs 20 dry contacts for external tripping and control
Metering Capabilities Voltage, frequency, power, energy, demand, load-to-trip percentage
Protection Features Overcurrent, over/under-frequency, breaker failure, thermal overload
Event Recording Up to 100,000 events in EEPROM (with high-usage warning)
LED Indicator Red LED for breaker closed (R in part number)
Display/Software Enhanced display with larger LCD and software (H in part number)
Operating Temperature -40°C to +55°C; conformal coating for harsh environments (HI in part number)
Dimensions 18 cm W x 16.5 cm D x 21.5 cm H (19-inch rack-mountable chassis)
Weight Approximately 5 kg
Certifications CE marked; suitable for industrial/utility applications
Standards Compliance ANSI/IEEE C37.90, IEC 60255 compliant for protective relays

Ordering Information



Parameter Details
Part Number Breakdown 750 (Series), P5 (Processor: Enhanced), G5 (Ground CT: 5 A), S5 (Zero Sequence CT: 5 A), HI (Harsh Environment Coating), A20 (Analog Outputs: 2), R (Red LED for Breaker Closed), T (Enhanced Communications: Modbus TCP/IP), H (Enhanced Display)
Available Options Variants for different CT ratings (1A/5A), control power ranges (LO/HI), I/O configurations, LED colors (G for green), and communication protocols
Customization Configurable via EnerVista 750 software; firmware updates for specific protection schemes
View full details

Product Description

Product Overview



Parameter Details
Part Number 750-P5-G5-S5-HI-A20-R-T-H
Product Name 750/760 Series Feeder Management Relay
Application Protection and control of distribution feeders, backup for transformers, power lines, and buses in industrial and utility systems
Compatibility Integrates with GE Multilin 750/760 series relays, EnerVista 750 software, and 19-inch rack panels
Function Provides overcurrent protection, metering, event recording, and enhanced communication for feeder management

Functional Specifications



Parameter Details
Phase Current Inputs 5 A (4 phase CT inputs)
Ground Current Inputs 5 A (sensitive ground CT input, G5 in part number)
Zero Sequence Current 5 A (standard ground CT input, S5 in part number)
Control Power Supply 88-300 V DC or 70-265 V AC (48-62 Hz) (HI in part number, high range)
Ethernet Interface 10Base-T with RJ45 port; enhanced communication (T in part number)
Communication Ports RS232 front panel for EnerVista software; rear RS485 for Modbus; supports Modbus TCP/IP (T in part number)
Analog Outputs 2 analog outputs (0-20 mA or 4-20 mA, A20 in part number)
Output Relays 8 electromechanical (5 general-purpose, 3 form-C trip contacts)
Logic Inputs 20 dry contacts for external tripping and control
Metering Capabilities Voltage, frequency, power, energy, demand, load-to-trip percentage
Protection Features Overcurrent, over/under-frequency, breaker failure, thermal overload
Event Recording Up to 100,000 events in EEPROM (with high-usage warning)
LED Indicator Red LED for breaker closed (R in part number)
Display/Software Enhanced display with larger LCD and software (H in part number)
Operating Temperature -40°C to +55°C; conformal coating for harsh environments (HI in part number)
Dimensions 18 cm W x 16.5 cm D x 21.5 cm H (19-inch rack-mountable chassis)
Weight Approximately 5 kg
Certifications CE marked; suitable for industrial/utility applications
Standards Compliance ANSI/IEEE C37.90, IEC 60255 compliant for protective relays

Ordering Information



Parameter Details
Part Number Breakdown 750 (Series), P5 (Processor: Enhanced), G5 (Ground CT: 5 A), S5 (Zero Sequence CT: 5 A), HI (Harsh Environment Coating), A20 (Analog Outputs: 2), R (Red LED for Breaker Closed), T (Enhanced Communications: Modbus TCP/IP), H (Enhanced Display)
Available Options Variants for different CT ratings (1A/5A), control power ranges (LO/HI), I/O configurations, LED colors (G for green), and communication protocols
Customization Configurable via EnerVista 750 software; firmware updates for specific protection schemes