Skip to product information
1 of 8

Foxboro RH924YA Field Control Processor 280

Foxboro RH924YA Field Control Processor 280

  • Manufacturer: Foxboro

  • Product No.: RH924YA

  • Condition:1000 in stock

  • Product Type: Field Control Processor 280

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 450g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Parameters for RH924YA (FCP280 Field Control Processor)

📘 Product Overview

Field Details
Manufacturer Schneider Electric (Foxboro)
Part Number RH924YA
Product Type Field Control Processor 280 (FCP280)
Function Performs regulatory, logic, timing, and sequential control, data acquisition, alarm detection, and notification with connected Foxboro DCS Fieldbus Modules (FBMs)
System Compatibility EcoStruxure Foxboro DCS Process Automation System (requires Control Core Services v9.0 or later)
Associated PSS Document PSS 41H-1FCP280 (Field Control Processor 280)

⚙️ Functional Specifications

Feature Specification
Processor Type ARM System on a Chip (SOC) with stored programs, high-speed communication
Memory - 128 MB SDRAM
- 128 MB flash memory
- Error Detection: ECC for single-bit error correction and multiple-bit error detection
Process I/O Communications - Module Fieldbus: HDLC
- Transmission Rate: 2 Mbps for 200 Series FBMs, 268 Kbps for 100 Series FBMs
Process I/O Capacity - 200 Series FBMs: Up to 32 per Expanded fieldbus (4 fieldbuses), max 128 FBMs total if used exclusively
- 100 Series FBMs: Max 128 total, max 64 per PIO channel/baseplate port (standard baseplates only)
- Mixed Configurations: Up to 128 total (e.g., 64 100 Series + 64 200 Series); each PIO channel supports either 2 Mbps or 268 Kbps exclusively
- Competitive Migration Modules: See device-specific PSS documents
- Sizing: Refer to B0700FY (FCP280 Sizing Guidelines)
Memory Allocation for Blocks - 15.75 MB (Classic OLUG)
- 19.75 MB (Enhanced OLUG, due to flash re-mapping)
Max Number of Blocks 8,000 total (7,993 configurable, 7 pre-defined); includes control blocks, ECBs, compounds
Block Executions per Second 16,000 blocks/second, maximum
Min Block Processing Cycle (BPC) 50 ms
Sequence Block Size 32 kB maximum per block
IPC Connections - 231 total: 200 source points, 30 sink points, 1 internal
- Source: FCP280 provides data to 200 destinations
- Sink: FCP280 receives data from 30 sources
OM Sink Lists 75 maximum (group updates to a destination)
OM Scanner Database 28,000 points (e.g., 7,500 points/s at 100 ms BPC, 18,000 at 500 ms)
OM Sink Points 11,250 maximum (points received from external sources)
Configurable Block Periods 0.05, 0.1, 0.2, 0.5, 0.6, 1, 2, 5, 6, 10, 30 s; 1, 10, 60 min
Block Processing Cycle 0.05, 0.1, 0.2, 0.5, 1.0 s (selectable at configuration)
Time to Marry Fault-Tolerant Modules <0.5 s
Internal Diagnostics - Power-up self-checking
- Run-time checks, watchdog timer
- Fault-tolerant pair: Synchronization and message compare operations
Control Features - Regulatory, logic, timing, sequential control
- Data acquisition, alarm detection/notification
- Algorithms in configurable control blocks for feedback, cascade, feedforward, nonlinear, and complex control schemes
- Alarm enhancements: Re-alarming on priority changes, time delay deadband, suppression
- Supports ladder logic, MDACT, DPIDA
Time Synchronization - Optional UTC from GPS satellites or internal software
- Synchronizes FBMs to 1 ms
- Supports SOE (1 ms time-stamped discrete points), TDR/TDA (10 ms time-stamped analog/digital points)
Firmware Upgrades - On-Line Image Upgrade (OLUG)
- Enhanced OLUG (EOLUG) for upgrades without process interruption
Self-Hosting Mode Boots with valid control database from flash memory without host workstation
Supported Devices - 2 Mbps Fieldbus: All 200 Series FBMs, FDSI modules, ISCM, migration modules for Siemens APACS+, Westinghouse WDPF, Fisher PROVOX, Honeywell TDC 2000
- 268 Kbps Fieldbus: 100 Series FBMs, SPECTRUM, SPEC 200, SPEC 200 MICRO, SPEC 200 CCM (standard baseplates only)
- Note: Foxboro Gas Chromatograph not supported

🔋 Power Requirements

Feature Specification
Input Voltage 24 V DC (redundant) typical
Power Consumption - Single module with redundant network adapters: 11 W max
- Fault-tolerant pair with redundant adapters: 20 W max

📏 Physical Specifications

Feature Specification
Configuration Single module or fault-tolerant pair (two modules with interconnecting connector on baseplate)
Mounting - 2-position baseplates (RH924YL, RH924YF, RH100JX) for horizontal/vertical DIN rail or rack mount (P0930AS kit, not for dual cable baseplate)
- Fault-tolerant pair requires dedicated slots
Dimensions (Module) - Height: 105 mm (4.13 in), 116 mm (4.7 in) with mounting lugs
- Width: 51.8 mm (2.04 in)
- Depth: 147 mm (5.79 in)
Weight 0.8 kg (1.76 lb) max for single module
Construction Rugged, die-cast aluminum housing, non-vented, CE certified for field enclosures
Baseplates - Standard Horizontal: RH924YL
- Standard Vertical: RH924YF
- Dual Cable: RH100JX (larger dimensions: 150 mm H x 247 mm W x 31.5 mm D)
Baseplate Size - Standard: 120 mm H x 216 mm W x 27.1 mm D (4.72 in x 8.5 in x 1.07 in)
- Dual Cable: 150 mm H x 247 mm W x 31.5 mm D (5.90 in x 9.72 in x 1.24 in)
Baseplate Mass ~0.45 kg (1.0 lb) without modules
Baseplate Material PC and ABS, UL94 V0 inflammability, black color
Cabling (Network) - Fiber: Multimode 62.5/125 μm, LC to MT-RJ, max 2 km (6,560 ft)
- Copper: Cat 5, RJ-45, max 100 m (328 ft)
Cabling (2 Mbps Fieldbus) - Without FCM2Fs: 60 m (198 ft) max per fieldbus
- With FCM2Fs: 60 m per segment, up to 4 pairs
- With FBI200: 305 m (1,000 ft) to FBI200 + 60 m to last baseplate
Cabling (268 Kbps Fieldbus) - To 200 Series via FBI200: 60 m max
- To 100 Series via FBI200: 1,830 m (6,000 ft) max
- Direct to 100 Series: 60 m (mixed configs) or 1 km (3,200 ft) (268 Kbps only)
- Cable: Twinaxial, shielded
Display LCD showing letterbug, role (Primary/Shadow/Single), part number, hardware revision, manufacturing date, OS version, network status
LED Indicators - Module: Operational status, fieldbus A/B communication (4 channels)
- Network Adapters: Power supply health, Control Network A/B, FCP280 communication

🌡️ Environmental Specifications

Parameter Operating Storage
Temperature -20 to +60°C (-4 to +140°F) (vertical DIN rail recommended for cooling) -40 to +70°C (-40 to +158°F)
Relative Humidity 5 to 95% (non-condensing) 5 to 95% (non-condensing)
Altitude -300 to +3,000 m (-1,000 to +10,000 ft) -300 to +12,000 m (-1,000 to +40,000 ft)
Contamination Class G3 (Harsh) per ISA S71.04; conformal coating; 10-year exposure per EIA 364-65A, Class III
Vibration 0.5 g (5 to 500 Hz) N/A

Note: Environmental limits may be enhanced by enclosure type (see PSS 41H-2GOV).

✅ Regulatory Compliance

Certification Type Details
Electromagnetic Compatibility (EMC) - European EMC Directive 2014/30/EU
- Meets EN 61326-1 Class A Emissions and Industrial Immunity Levels
Product Safety - UL/UL-C listed for Class I, Groups A-D, Division 2, T4 enclosure-based systems (per B0400FA); meets Class 2 per NEC (NFPA No.70), CEC (CSA C22.1)
- European Low Voltage Directive 2014/35/EU, ATEX Directive 2014/34/EU: ATEX (DEMKO) Ex nA IIC T4 Gc for Zone 2 enclosures (per B0400FA)
- ABS Type Approved, Bureau Veritas Marine Certification (EC31)
IECEx Certification IECEx Certified
Security Certifications - Wurldtech Achilles Certification Level 1
- ISASecure Certification, EDSA Level 1
California Prop 65 Contains lead/lead compounds; warning required per www.p65warnings.ca.gov

🔌 Additional Features

Feature Details
Fault-Tolerance - Patented dual-module operation; modules process data in parallel, compare messages bit-for-bit
- Self-diagnostics detect faults; non-affected module takes control without process interruption
Network Adapters - Fiber (RH924WA): 2 km max
- Copper (RH924UQ): 100 m max
- Two adapters required for fault-tolerant pair
Baseplate Support - Standard: RH924YL (horizontal), RH924YF (vertical)
- Dual Cable: RH100JX (supports separate A/B cables, dedicated time strobe ports)
Splitters/Terminators - Fieldbus Terminator: P0916RB
- Terminator/Splitter: RH924ZJ, RH928CY
- Time Strobe Terminator: RH924ZQ (standard baseplates only)
- Fieldbus Splitter: RH928CV (268 Kbps fieldbus)
Upgrade Compatibility - Replaces FCP270, ZCP270, CP60; imports CP270 database
- Requires FBI200 for 100 Series FBMs to extend distance or replace older CPs
Enclosure Suitability Class G3 harsh environments; CE certified for field mounting without EMI cabinets

📦 Ordering Information

Field Details
Part Number RH924YA (FCP280 Module)
Associated Components - Baseplates: RH924YL, RH924YF, RH100JX
- Adapters: RH924WA, RH924UQ
- Splitters: RH928CV, RH924ZJ, RH928CY, RH924ZQ
- Terminator: P0916RB
Related PSS Documents - PSS 41H-1FCP280 (FCP280)
- PSS 41H-2SBASPLT (Baseplates)
- PSS 41H-2FBI200 (FBI200)
- PSS 41H-7NWEQUIP (Control Network)
- PSS 41H-2CERTS (Certifications)
- B0700FW (FCP280 User’s Guide)
- B0700FY (Sizing Guidelines)
- B0400FA (Subsystem User’s Guide)

 

View full details

Product Description

Product Parameters for RH924YA (FCP280 Field Control Processor)

📘 Product Overview

Field Details
Manufacturer Schneider Electric (Foxboro)
Part Number RH924YA
Product Type Field Control Processor 280 (FCP280)
Function Performs regulatory, logic, timing, and sequential control, data acquisition, alarm detection, and notification with connected Foxboro DCS Fieldbus Modules (FBMs)
System Compatibility EcoStruxure Foxboro DCS Process Automation System (requires Control Core Services v9.0 or later)
Associated PSS Document PSS 41H-1FCP280 (Field Control Processor 280)

⚙️ Functional Specifications

Feature Specification
Processor Type ARM System on a Chip (SOC) with stored programs, high-speed communication
Memory - 128 MB SDRAM
- 128 MB flash memory
- Error Detection: ECC for single-bit error correction and multiple-bit error detection
Process I/O Communications - Module Fieldbus: HDLC
- Transmission Rate: 2 Mbps for 200 Series FBMs, 268 Kbps for 100 Series FBMs
Process I/O Capacity - 200 Series FBMs: Up to 32 per Expanded fieldbus (4 fieldbuses), max 128 FBMs total if used exclusively
- 100 Series FBMs: Max 128 total, max 64 per PIO channel/baseplate port (standard baseplates only)
- Mixed Configurations: Up to 128 total (e.g., 64 100 Series + 64 200 Series); each PIO channel supports either 2 Mbps or 268 Kbps exclusively
- Competitive Migration Modules: See device-specific PSS documents
- Sizing: Refer to B0700FY (FCP280 Sizing Guidelines)
Memory Allocation for Blocks - 15.75 MB (Classic OLUG)
- 19.75 MB (Enhanced OLUG, due to flash re-mapping)
Max Number of Blocks 8,000 total (7,993 configurable, 7 pre-defined); includes control blocks, ECBs, compounds
Block Executions per Second 16,000 blocks/second, maximum
Min Block Processing Cycle (BPC) 50 ms
Sequence Block Size 32 kB maximum per block
IPC Connections - 231 total: 200 source points, 30 sink points, 1 internal
- Source: FCP280 provides data to 200 destinations
- Sink: FCP280 receives data from 30 sources
OM Sink Lists 75 maximum (group updates to a destination)
OM Scanner Database 28,000 points (e.g., 7,500 points/s at 100 ms BPC, 18,000 at 500 ms)
OM Sink Points 11,250 maximum (points received from external sources)
Configurable Block Periods 0.05, 0.1, 0.2, 0.5, 0.6, 1, 2, 5, 6, 10, 30 s; 1, 10, 60 min
Block Processing Cycle 0.05, 0.1, 0.2, 0.5, 1.0 s (selectable at configuration)
Time to Marry Fault-Tolerant Modules <0.5 s
Internal Diagnostics - Power-up self-checking
- Run-time checks, watchdog timer
- Fault-tolerant pair: Synchronization and message compare operations
Control Features - Regulatory, logic, timing, sequential control
- Data acquisition, alarm detection/notification
- Algorithms in configurable control blocks for feedback, cascade, feedforward, nonlinear, and complex control schemes
- Alarm enhancements: Re-alarming on priority changes, time delay deadband, suppression
- Supports ladder logic, MDACT, DPIDA
Time Synchronization - Optional UTC from GPS satellites or internal software
- Synchronizes FBMs to 1 ms
- Supports SOE (1 ms time-stamped discrete points), TDR/TDA (10 ms time-stamped analog/digital points)
Firmware Upgrades - On-Line Image Upgrade (OLUG)
- Enhanced OLUG (EOLUG) for upgrades without process interruption
Self-Hosting Mode Boots with valid control database from flash memory without host workstation
Supported Devices - 2 Mbps Fieldbus: All 200 Series FBMs, FDSI modules, ISCM, migration modules for Siemens APACS+, Westinghouse WDPF, Fisher PROVOX, Honeywell TDC 2000
- 268 Kbps Fieldbus: 100 Series FBMs, SPECTRUM, SPEC 200, SPEC 200 MICRO, SPEC 200 CCM (standard baseplates only)
- Note: Foxboro Gas Chromatograph not supported

🔋 Power Requirements

Feature Specification
Input Voltage 24 V DC (redundant) typical
Power Consumption - Single module with redundant network adapters: 11 W max
- Fault-tolerant pair with redundant adapters: 20 W max

📏 Physical Specifications

Feature Specification
Configuration Single module or fault-tolerant pair (two modules with interconnecting connector on baseplate)
Mounting - 2-position baseplates (RH924YL, RH924YF, RH100JX) for horizontal/vertical DIN rail or rack mount (P0930AS kit, not for dual cable baseplate)
- Fault-tolerant pair requires dedicated slots
Dimensions (Module) - Height: 105 mm (4.13 in), 116 mm (4.7 in) with mounting lugs
- Width: 51.8 mm (2.04 in)
- Depth: 147 mm (5.79 in)
Weight 0.8 kg (1.76 lb) max for single module
Construction Rugged, die-cast aluminum housing, non-vented, CE certified for field enclosures
Baseplates - Standard Horizontal: RH924YL
- Standard Vertical: RH924YF
- Dual Cable: RH100JX (larger dimensions: 150 mm H x 247 mm W x 31.5 mm D)
Baseplate Size - Standard: 120 mm H x 216 mm W x 27.1 mm D (4.72 in x 8.5 in x 1.07 in)
- Dual Cable: 150 mm H x 247 mm W x 31.5 mm D (5.90 in x 9.72 in x 1.24 in)
Baseplate Mass ~0.45 kg (1.0 lb) without modules
Baseplate Material PC and ABS, UL94 V0 inflammability, black color
Cabling (Network) - Fiber: Multimode 62.5/125 μm, LC to MT-RJ, max 2 km (6,560 ft)
- Copper: Cat 5, RJ-45, max 100 m (328 ft)
Cabling (2 Mbps Fieldbus) - Without FCM2Fs: 60 m (198 ft) max per fieldbus
- With FCM2Fs: 60 m per segment, up to 4 pairs
- With FBI200: 305 m (1,000 ft) to FBI200 + 60 m to last baseplate
Cabling (268 Kbps Fieldbus) - To 200 Series via FBI200: 60 m max
- To 100 Series via FBI200: 1,830 m (6,000 ft) max
- Direct to 100 Series: 60 m (mixed configs) or 1 km (3,200 ft) (268 Kbps only)
- Cable: Twinaxial, shielded
Display LCD showing letterbug, role (Primary/Shadow/Single), part number, hardware revision, manufacturing date, OS version, network status
LED Indicators - Module: Operational status, fieldbus A/B communication (4 channels)
- Network Adapters: Power supply health, Control Network A/B, FCP280 communication

🌡️ Environmental Specifications

Parameter Operating Storage
Temperature -20 to +60°C (-4 to +140°F) (vertical DIN rail recommended for cooling) -40 to +70°C (-40 to +158°F)
Relative Humidity 5 to 95% (non-condensing) 5 to 95% (non-condensing)
Altitude -300 to +3,000 m (-1,000 to +10,000 ft) -300 to +12,000 m (-1,000 to +40,000 ft)
Contamination Class G3 (Harsh) per ISA S71.04; conformal coating; 10-year exposure per EIA 364-65A, Class III
Vibration 0.5 g (5 to 500 Hz) N/A

Note: Environmental limits may be enhanced by enclosure type (see PSS 41H-2GOV).

✅ Regulatory Compliance

Certification Type Details
Electromagnetic Compatibility (EMC) - European EMC Directive 2014/30/EU
- Meets EN 61326-1 Class A Emissions and Industrial Immunity Levels
Product Safety - UL/UL-C listed for Class I, Groups A-D, Division 2, T4 enclosure-based systems (per B0400FA); meets Class 2 per NEC (NFPA No.70), CEC (CSA C22.1)
- European Low Voltage Directive 2014/35/EU, ATEX Directive 2014/34/EU: ATEX (DEMKO) Ex nA IIC T4 Gc for Zone 2 enclosures (per B0400FA)
- ABS Type Approved, Bureau Veritas Marine Certification (EC31)
IECEx Certification IECEx Certified
Security Certifications - Wurldtech Achilles Certification Level 1
- ISASecure Certification, EDSA Level 1
California Prop 65 Contains lead/lead compounds; warning required per www.p65warnings.ca.gov

🔌 Additional Features

Feature Details
Fault-Tolerance - Patented dual-module operation; modules process data in parallel, compare messages bit-for-bit
- Self-diagnostics detect faults; non-affected module takes control without process interruption
Network Adapters - Fiber (RH924WA): 2 km max
- Copper (RH924UQ): 100 m max
- Two adapters required for fault-tolerant pair
Baseplate Support - Standard: RH924YL (horizontal), RH924YF (vertical)
- Dual Cable: RH100JX (supports separate A/B cables, dedicated time strobe ports)
Splitters/Terminators - Fieldbus Terminator: P0916RB
- Terminator/Splitter: RH924ZJ, RH928CY
- Time Strobe Terminator: RH924ZQ (standard baseplates only)
- Fieldbus Splitter: RH928CV (268 Kbps fieldbus)
Upgrade Compatibility - Replaces FCP270, ZCP270, CP60; imports CP270 database
- Requires FBI200 for 100 Series FBMs to extend distance or replace older CPs
Enclosure Suitability Class G3 harsh environments; CE certified for field mounting without EMI cabinets

📦 Ordering Information

Field Details
Part Number RH924YA (FCP280 Module)
Associated Components - Baseplates: RH924YL, RH924YF, RH100JX
- Adapters: RH924WA, RH924UQ
- Splitters: RH928CV, RH924ZJ, RH928CY, RH924ZQ
- Terminator: P0916RB
Related PSS Documents - PSS 41H-1FCP280 (FCP280)
- PSS 41H-2SBASPLT (Baseplates)
- PSS 41H-2FBI200 (FBI200)
- PSS 41H-7NWEQUIP (Control Network)
- PSS 41H-2CERTS (Certifications)
- B0700FW (FCP280 User’s Guide)
- B0700FY (Sizing Guidelines)
- B0400FA (Subsystem User’s Guide)

 

Download PDF file here:

Click to Download PDF

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)