Skip to product information
1 of 8

Foxboro RH924WA Fiber Adapter for FCP280

Foxboro RH924WA Fiber Adapter for FCP280

  • Manufacturer: Foxboro

  • Product No.: RH924WA FCP280

  • Condition:1000 in stock

  • Product Type: Fiber Adapter for FCP280

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 450g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Parameters for RH924WA (Fiber Adapter)

📘 Product Overview

Field Details
Manufacturer Schneider Electric (Foxboro)
Part Number RH924WA
Product Type Fiber Adapter for FCP280
Function Connects the FCP280 to the Foxboro DCS Control Network via 100 Mbps Ethernet fiber optic cables
System Compatibility EcoStruxure Foxboro DCS Process Automation System (FCP280)
Associated PSS Document PSS 41H-1FCP280 (Field Control Processor 280)

⚙️ Functional Specifications

Feature Specification
Network Connection Connects FCP280 to Ethernet switch in the Foxboro DCS Control Network
Communication Type 100 Mbps Ethernet, fiber optic-based
Cabling - Cable Material: Multimode fiber (MMF) 62.5/125 μm plenum
- Connectors: Two ceramic type LC connectors (network adapter end), MT-RJ connector (switch end)
- Cable Lengths: Up to 50 m (164 ft) (Schneider Electric supplied); user-supplied for >50 m, max 2 km (6,560 ft) from switch to FCP280
Role in Network - Passes inbound traffic from either of two Ethernet switches to both FCP280 modules (in fault-tolerant pair)
- Passes outbound traffic from the primary FCP280 module to either switch
Power Supply Receives power from the FCP280 baseplate (no separate power input required)
Visual Indicators LEDs on the adapter indicate:
- Internal and external power supply health status
- Communications activity to Control Network A and B links, and to FCP280(s)

🔋 Power Requirements

Feature Specification
Power Source Supplied by FCP280 baseplate (24 V DC typical)
Power Consumption Included in FCP280 module consumption:
- Single module with redundant adapters: 11 W max
- Fault-tolerant pair with redundant adapters: 20 W max

📏 Physical Specifications

Feature Specification
Mounting Mounts on FCP280 baseplate (RH924YL, RH924YF, or RH100JX) in dedicated slots for network adapters
Construction Rugged, die-cast aluminum housing, designed for non-vented field enclosures
Dimensions Not explicitly specified for adapter alone; fits within baseplate dimensions:
- Standard Baseplate: 120 mm H x 216 mm W x 27.1 mm D (4.72 in x 8.5 in x 1.07 in)
- Dual Cable Baseplate: 150 mm H x 247 mm W x 31.5 mm D (5.90 in x 9.72 in x 1.24 in)
Weight Not explicitly specified; included in baseplate mass (~0.45 kg / 1.0 lb without modules)
Compatibility Compatible with standard (RH924YL, RH924YF) and dual cable (RH100JX) FCP280 baseplates

🌡️ Environmental Specifications

Parameter Operating Storage
Temperature -20 to +60°C (-4 to +140°F) -40 to +70°C (-40 to +158°F)
Relative Humidity 5 to 95% (non-condensing) 5 to 95% (non-condensing)
Altitude -300 to +3,000 m (-1,000 to +10,000 ft) -300 to +12,000 m (-1,000 to +40,000 ft)
Contamination Class G3 (Harsh) per ISA S71.04; conformal coating; no effect after 10-year simulated exposure per EIA 364-65A, Class III
Vibration 0.5 g (5 to 500 Hz) N/A

Note: Environmental limits may be enhanced by the enclosure type (refer to the applicable enclosure PSS, e.g., PSS 41H-2GOV).

✅ Regulatory Compliance

Certification Type Details
Electromagnetic Compatibility (EMC) - European EMC Directive 2014/30/EU
- Meets EN 61326-1 Class A Emissions and Industrial Immunity Levels
Product Safety - UL/UL-C listed for Class I, Groups A-D, Division 2, T4 enclosure-based systems when connected as described in B0400FA; meets Class 2 requirements per NEC (NFPA No.70) and CEC (CSA C22.1)
- European Low Voltage Directive 2014/35/EU and ATEX Directive 2014/34/EU: ATEX (DEMKO) Ex nA IIC T4 Gc certified for Zone 2 enclosures (per B0400FA)
- ABS Type Approved and Bureau Veritas Marine Certification for Environmental Category EC31
IECEx Certification IECEx Certified
Security Certifications - Wurldtech Achilles Certification Level 1
- ISASecure Certification, EDSA Level 1
California Prop 65 Contains lead/lead compounds; warning required per www.p65warnings.ca.gov

🔌 Additional Features

Feature Details
Installation Mounts on FCP280 baseplate alongside copper adapter (RH924UQ) option; two adapters (fiber or copper) required for fault-tolerant FCP280 pair
Network Redundancy Supports redundant network connections (A and B links) to ensure continuous communication if one path fails
Enclosure Suitability Designed for Class G3 harsh environments; CE certified for field mounting in enclosures without special cabinets for EMI protection

📦 Ordering Information

Field Details
Part Number RH924WA (Fiber Adapter)
Associated Baseplates - RH924YL (Horizontal Standard)
- RH924YF (Vertical Standard)
- RH100JX (Dual Cable, Horizontal/Vertical)
Related PSS Documents - PSS 41H-1FCP280 (FCP280)
- PSS 41H-2SBASPLT (Baseplates)
- PSS 41H-7NWEQUIP (Control Network Ethernet Equipment)
- PSS 41H-2CERTS (Certifications)
- B0400FA (Subsystem User’s Guide)
- B0700FW (FCP280 User’s Guide)

 

View full details

Product Description

Product Parameters for RH924WA (Fiber Adapter)

📘 Product Overview

Field Details
Manufacturer Schneider Electric (Foxboro)
Part Number RH924WA
Product Type Fiber Adapter for FCP280
Function Connects the FCP280 to the Foxboro DCS Control Network via 100 Mbps Ethernet fiber optic cables
System Compatibility EcoStruxure Foxboro DCS Process Automation System (FCP280)
Associated PSS Document PSS 41H-1FCP280 (Field Control Processor 280)

⚙️ Functional Specifications

Feature Specification
Network Connection Connects FCP280 to Ethernet switch in the Foxboro DCS Control Network
Communication Type 100 Mbps Ethernet, fiber optic-based
Cabling - Cable Material: Multimode fiber (MMF) 62.5/125 μm plenum
- Connectors: Two ceramic type LC connectors (network adapter end), MT-RJ connector (switch end)
- Cable Lengths: Up to 50 m (164 ft) (Schneider Electric supplied); user-supplied for >50 m, max 2 km (6,560 ft) from switch to FCP280
Role in Network - Passes inbound traffic from either of two Ethernet switches to both FCP280 modules (in fault-tolerant pair)
- Passes outbound traffic from the primary FCP280 module to either switch
Power Supply Receives power from the FCP280 baseplate (no separate power input required)
Visual Indicators LEDs on the adapter indicate:
- Internal and external power supply health status
- Communications activity to Control Network A and B links, and to FCP280(s)

🔋 Power Requirements

Feature Specification
Power Source Supplied by FCP280 baseplate (24 V DC typical)
Power Consumption Included in FCP280 module consumption:
- Single module with redundant adapters: 11 W max
- Fault-tolerant pair with redundant adapters: 20 W max

📏 Physical Specifications

Feature Specification
Mounting Mounts on FCP280 baseplate (RH924YL, RH924YF, or RH100JX) in dedicated slots for network adapters
Construction Rugged, die-cast aluminum housing, designed for non-vented field enclosures
Dimensions Not explicitly specified for adapter alone; fits within baseplate dimensions:
- Standard Baseplate: 120 mm H x 216 mm W x 27.1 mm D (4.72 in x 8.5 in x 1.07 in)
- Dual Cable Baseplate: 150 mm H x 247 mm W x 31.5 mm D (5.90 in x 9.72 in x 1.24 in)
Weight Not explicitly specified; included in baseplate mass (~0.45 kg / 1.0 lb without modules)
Compatibility Compatible with standard (RH924YL, RH924YF) and dual cable (RH100JX) FCP280 baseplates

🌡️ Environmental Specifications

Parameter Operating Storage
Temperature -20 to +60°C (-4 to +140°F) -40 to +70°C (-40 to +158°F)
Relative Humidity 5 to 95% (non-condensing) 5 to 95% (non-condensing)
Altitude -300 to +3,000 m (-1,000 to +10,000 ft) -300 to +12,000 m (-1,000 to +40,000 ft)
Contamination Class G3 (Harsh) per ISA S71.04; conformal coating; no effect after 10-year simulated exposure per EIA 364-65A, Class III
Vibration 0.5 g (5 to 500 Hz) N/A

Note: Environmental limits may be enhanced by the enclosure type (refer to the applicable enclosure PSS, e.g., PSS 41H-2GOV).

✅ Regulatory Compliance

Certification Type Details
Electromagnetic Compatibility (EMC) - European EMC Directive 2014/30/EU
- Meets EN 61326-1 Class A Emissions and Industrial Immunity Levels
Product Safety - UL/UL-C listed for Class I, Groups A-D, Division 2, T4 enclosure-based systems when connected as described in B0400FA; meets Class 2 requirements per NEC (NFPA No.70) and CEC (CSA C22.1)
- European Low Voltage Directive 2014/35/EU and ATEX Directive 2014/34/EU: ATEX (DEMKO) Ex nA IIC T4 Gc certified for Zone 2 enclosures (per B0400FA)
- ABS Type Approved and Bureau Veritas Marine Certification for Environmental Category EC31
IECEx Certification IECEx Certified
Security Certifications - Wurldtech Achilles Certification Level 1
- ISASecure Certification, EDSA Level 1
California Prop 65 Contains lead/lead compounds; warning required per www.p65warnings.ca.gov

🔌 Additional Features

Feature Details
Installation Mounts on FCP280 baseplate alongside copper adapter (RH924UQ) option; two adapters (fiber or copper) required for fault-tolerant FCP280 pair
Network Redundancy Supports redundant network connections (A and B links) to ensure continuous communication if one path fails
Enclosure Suitability Designed for Class G3 harsh environments; CE certified for field mounting in enclosures without special cabinets for EMI protection

📦 Ordering Information

Field Details
Part Number RH924WA (Fiber Adapter)
Associated Baseplates - RH924YL (Horizontal Standard)
- RH924YF (Vertical Standard)
- RH100JX (Dual Cable, Horizontal/Vertical)
Related PSS Documents - PSS 41H-1FCP280 (FCP280)
- PSS 41H-2SBASPLT (Baseplates)
- PSS 41H-7NWEQUIP (Control Network Ethernet Equipment)
- PSS 41H-2CERTS (Certifications)
- B0400FA (Subsystem User’s Guide)
- B0700FW (FCP280 User’s Guide)

 

Download PDF file here:

Click to Download PDF

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)