Skip to product information
1 of 9

Foxboro P0917MF Termination Assembly

Foxboro P0917MF Termination Assembly

  • Manufacturer: Foxboro

  • Product No.: P0917MF

  • Condition:1000 in stock

  • Product Type: Termination Assembly

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Parameters for P0917MF Termination Assembly

📘 Product Overview

Field Details
Manufacturer Foxboro (by Schneider Electric)
Part Number P0917MF
Product Type Termination Assembly (TA) for FBM207c
Function Interfaces 16 channels of 48 V dc contact sense inputs for FBM207c
Associated FBM FBM207c (Channel Isolated, Voltage Monitor/Contact Sense Input Module)
System Compatibility Foxboro Evo Process Automation System, Standard 200 Series FBM Subsystem

⚙️ Functional Specifications

Feature Specification
Signal Inputs
- Type 48 V dc Contact Sense (internal source)
- Number of Channels 16 group-isolated input channels
- Input Voltage 48 V dc nominal open circuit voltage
- Short Circuit Current 2.5 mA ± 20%
- On-State Resistance Up to 1 kΩ
- Off-State Resistance 100 kΩ minimum
Signal Outputs None (FBM207c is input-only for this TA)
Isolation Group isolation for input channels; specific isolation ratings not detailed in the document but typically 600 V ac for 1 minute between channels and ground (based on FBM standards)
Connection Type Compression or ring-lug terminals; connects to FBM via 37-pin D-subminiature cable
Supported Cables Type 4/4H (Baseplate to TA): P/PVC, LSZH, or H/XLPE; up to 30 m (98 ft)
Power Requirements Supplied by FBM207c; no direct power input to TA
Calibration No calibration required

🔌 Physical Specifications

Feature Specification
Material Polypropylene (PVC) or Polyamide (PA)
Mass Approximately 420–908 g (0.93–2.0 lb), depending on TA configuration (based on similar TAs)
Dimensions Typical for 200 Series TAs: Width ~267–286 mm, Height ~125 mm (exact dimensions not specified for P0917MF)
Mounting DIN rail (32 mm or 35 mm)
Cable Connections Compression terminals: 0.2 to 4 mm² (24 to 12 AWG); Ring-lug: #6, 0.5 to 4 mm²

🌡️ Environmental Specifications

Parameter Specification
Operating Temperature PVC: -20 to +50°C (-4 to +122°F); PA: -20 to +70°C (-4 to +158°F)
Storage Temperature -40 to +70°C (-40 to +158°F)
Relative Humidity 5 to 95% (non-condensing)
Operating Altitude -300 to +3,000 m (-1,000 to +10,000 ft)
Storage Altitude -300 to +12,000 m (-1,000 to +40,000 ft)
Contamination Class G3 (Harsh) per ISA S71.04; EIA Standard 364-65, Class III
Vibration 0.75 m/s² (5 to 500 Hz)

✅ Regulatory Compliance

Certification Type Details
Certification Types Type 1, Type 2 (see definitions below)
Underwriters Laboratories (UL/UL-C) Listed for Class I, Groups A-D, Division 2, Temperature Code T4 hazardous locations; suitable for enclosure-based systems
ATEX (DEMKO) Certified Ex nA IIC T4 Gc for Zone 2 potentially explosive atmospheres; complies with ATEX Directive for II 3 G use
Type 1 Certification UL/UL-C listed for Class I, Groups A-D, Division 2, T4; ATEX Ex nA IIC T4 for Zone 2
Type 2 Certification UL/UL-C listed as associated apparatus for supplying non-incendive field circuits for Class I, Groups A-D, Division 2; ATEX certified for non-incendive field circuits for Zone 2, Group IIC; field circuits are Class 2 limited energy (60 V dc, 30 V ac, 100 VA or less) if customer equipment meets Class 2 limits
Marine Certification Bureau Veritas Certified for Marine Installations in Environmental Category EC31C; ABS Marine Type Approved
EMC Compliance Meets European EMC Directive 2014/30/EU; EN61326:2013 Class A Emissions and Industrial Immunity levels
Low Voltage Directive Complies with European Low Voltage Directive for safety

📦 Ordering Information

Field Details
Part Number P0917MF
Associated FBM FBM207c (Channel Isolated, Voltage Monitor/Contact Sense Input Module)
Other TAs for FBM207c P0917MH, RH917MG, P0917MJ
Conditions of Use Must be installed and used as specified in the Standard and Compact 200 Series Subsystem User’s Guide (B0400FA)

🔧 Additional Notes
  • FBM207c Functionality: The FBM207c, paired with P0917MF, supports 16 channels of 48 V dc contact sense inputs, suitable for monitoring high-voltage contact closures in process automation.
  • Class 2 Limited Energy: Field circuits are Class 2 limited energy (60 V dc, 30 V ac, 100 VA or less) when customer-supplied equipment adheres to Class 2 limits, enhancing safety in hazardous locations.
  • Non-Incendive Circuits: The Type 2 certification ensures the TA can supply non-incendive field circuits, making it suitable for Division 2 and Zone 2 environments when properly configured.
  • Marine Applications: The TA is certified for marine installations, ensuring reliability in harsh environmental conditions like those found on ships or offshore platforms.

View full details

Product Description

Product Parameters for P0917MF Termination Assembly

📘 Product Overview

Field Details
Manufacturer Foxboro (by Schneider Electric)
Part Number P0917MF
Product Type Termination Assembly (TA) for FBM207c
Function Interfaces 16 channels of 48 V dc contact sense inputs for FBM207c
Associated FBM FBM207c (Channel Isolated, Voltage Monitor/Contact Sense Input Module)
System Compatibility Foxboro Evo Process Automation System, Standard 200 Series FBM Subsystem

⚙️ Functional Specifications

Feature Specification
Signal Inputs
- Type 48 V dc Contact Sense (internal source)
- Number of Channels 16 group-isolated input channels
- Input Voltage 48 V dc nominal open circuit voltage
- Short Circuit Current 2.5 mA ± 20%
- On-State Resistance Up to 1 kΩ
- Off-State Resistance 100 kΩ minimum
Signal Outputs None (FBM207c is input-only for this TA)
Isolation Group isolation for input channels; specific isolation ratings not detailed in the document but typically 600 V ac for 1 minute between channels and ground (based on FBM standards)
Connection Type Compression or ring-lug terminals; connects to FBM via 37-pin D-subminiature cable
Supported Cables Type 4/4H (Baseplate to TA): P/PVC, LSZH, or H/XLPE; up to 30 m (98 ft)
Power Requirements Supplied by FBM207c; no direct power input to TA
Calibration No calibration required

🔌 Physical Specifications

Feature Specification
Material Polypropylene (PVC) or Polyamide (PA)
Mass Approximately 420–908 g (0.93–2.0 lb), depending on TA configuration (based on similar TAs)
Dimensions Typical for 200 Series TAs: Width ~267–286 mm, Height ~125 mm (exact dimensions not specified for P0917MF)
Mounting DIN rail (32 mm or 35 mm)
Cable Connections Compression terminals: 0.2 to 4 mm² (24 to 12 AWG); Ring-lug: #6, 0.5 to 4 mm²

🌡️ Environmental Specifications

Parameter Specification
Operating Temperature PVC: -20 to +50°C (-4 to +122°F); PA: -20 to +70°C (-4 to +158°F)
Storage Temperature -40 to +70°C (-40 to +158°F)
Relative Humidity 5 to 95% (non-condensing)
Operating Altitude -300 to +3,000 m (-1,000 to +10,000 ft)
Storage Altitude -300 to +12,000 m (-1,000 to +40,000 ft)
Contamination Class G3 (Harsh) per ISA S71.04; EIA Standard 364-65, Class III
Vibration 0.75 m/s² (5 to 500 Hz)

✅ Regulatory Compliance

Certification Type Details
Certification Types Type 1, Type 2 (see definitions below)
Underwriters Laboratories (UL/UL-C) Listed for Class I, Groups A-D, Division 2, Temperature Code T4 hazardous locations; suitable for enclosure-based systems
ATEX (DEMKO) Certified Ex nA IIC T4 Gc for Zone 2 potentially explosive atmospheres; complies with ATEX Directive for II 3 G use
Type 1 Certification UL/UL-C listed for Class I, Groups A-D, Division 2, T4; ATEX Ex nA IIC T4 for Zone 2
Type 2 Certification UL/UL-C listed as associated apparatus for supplying non-incendive field circuits for Class I, Groups A-D, Division 2; ATEX certified for non-incendive field circuits for Zone 2, Group IIC; field circuits are Class 2 limited energy (60 V dc, 30 V ac, 100 VA or less) if customer equipment meets Class 2 limits
Marine Certification Bureau Veritas Certified for Marine Installations in Environmental Category EC31C; ABS Marine Type Approved
EMC Compliance Meets European EMC Directive 2014/30/EU; EN61326:2013 Class A Emissions and Industrial Immunity levels
Low Voltage Directive Complies with European Low Voltage Directive for safety

📦 Ordering Information

Field Details
Part Number P0917MF
Associated FBM FBM207c (Channel Isolated, Voltage Monitor/Contact Sense Input Module)
Other TAs for FBM207c P0917MH, RH917MG, P0917MJ
Conditions of Use Must be installed and used as specified in the Standard and Compact 200 Series Subsystem User’s Guide (B0400FA)

🔧 Additional Notes
  • FBM207c Functionality: The FBM207c, paired with P0917MF, supports 16 channels of 48 V dc contact sense inputs, suitable for monitoring high-voltage contact closures in process automation.
  • Class 2 Limited Energy: Field circuits are Class 2 limited energy (60 V dc, 30 V ac, 100 VA or less) when customer-supplied equipment adheres to Class 2 limits, enhancing safety in hazardous locations.
  • Non-Incendive Circuits: The Type 2 certification ensures the TA can supply non-incendive field circuits, making it suitable for Division 2 and Zone 2 environments when properly configured.
  • Marine Applications: The TA is certified for marine installations, ensuring reliability in harsh environmental conditions like those found on ships or offshore platforms.