Product Parameters for P0916RB Fieldbus Baseplate Terminator
📘 Product Overview
| Field | Details |
|---|---|
| Manufacturer | Foxboro (by Schneider Electric) |
| Part Number | P0916RB (superseded by RH916RB) |
| Product Type | Fieldbus Baseplate Terminator |
| Function | Terminates the 2 Mbps HDLC Module Fieldbus at the CP end or the last 200 Series baseplate in a daisy chain when Time Strobe or split A/B fieldbus cables are not required |
| System Compatibility | Foxboro Evo Process Automation System, Standard 200 Series Subsystem |
⚙️ Functional Specifications
| Feature | Specification |
|---|---|
| Role | Terminates the 2 Mbps HDLC Module Fieldbus to ensure proper signal integrity in a daisy-chained configuration |
| Application | Used at the control processor (e.g., FCP280, FCP270) end or the last FBM-supporting baseplate in the chain when no Time Strobe or A/B split cables are needed |
| Fieldbus Type | 2 Mbps HDLC Module Fieldbus for 200 Series FBMs; not compatible with 268 Kbps Fieldbus for 100 Series FBMs |
| Connector Compatibility | Connects to A/B Module Fieldbus connectors on 200 Series baseplates (shielded twisted-pair cables) |
| Usage Limitation | Not used when Time Strobe signals or A/B fieldbus splitting is required (e.g., with RH926KW, RH924ZJ, RH928CY, or RH926KZ terminators/splitters) |
| Baseplate Compatibility | Compatible with FBM-supporting baseplates (2, 4, 8 positions: RH926KE, RH926HM, RH926HT, etc.) and FCP270/FCP280 baseplates (RH924YL, P0926HC, etc.), except the dual cable FCP280 baseplate (RH100JX) for 100 Series FBMs |
| Installation | Plugs into the Module Fieldbus connector on the baseplate; no additional configuration required |
🔌 Physical Specifications
| Feature | Specification |
|---|---|
| Material | Not explicitly specified (likely PC and ABS, UL94 V0 flame rating, per baseplate construction) |
| Weight | Not specified (typically lightweight, <100 g, as a passive terminator) |
| Dimensions | Not specified (compact, designed to fit standard Module Fieldbus connector on 200 Series baseplates) |
| Mounting | Attaches directly to the A/B Module Fieldbus connector on the baseplate |
| Color | Not specified (likely black, consistent with baseplate color) |
🌡️ Environmental Specifications
| Parameter | Specification |
|---|---|
| Operating Temperature | -20 to +60°C (-4 to +140°F) (aligned with 200 Series baseplate limits) |
| Storage Temperature | -40 to +70°C (-40 to +158°F) |
| Relative Humidity | 5 to 95% (non-condensing) |
| Operating Altitude | -300 to +3,000 m (-1,000 to +10,000 ft) |
| Storage Altitude | -300 to +12,000 m (-1,000 to +40,000 ft) |
| Contamination | Class G3 (harsh) per ISA S71.04 (non-enclosure or enclosure-mounted) |
| Pollution Degree | Pollution degree 2 per IEC 664-1 |
✅ Regulatory Compliance
| Standard | Details |
|---|---|
| Electromagnetic Compatibility (EMC) | Meets European EMC Directive 2014/30/EU, EN 61326:2013 Class A Emissions and Industrial Immunity Levels |
| Product Safety | UL/UL-C listed for Class I, Groups A-D, Division 2, T4 enclosure-based systems; meets Class 2 requirements per NFPA 70 (NEC) Article 725 and CSA C22.1 Section 16, as specified in B0400FA |
| ATEX Certification | Ex nA IIC T4 Gc certified for ATEX Zone 2 when connected per B0400FA |
| Marine Certification | ABS Type Approved and Bureau Veritas EC31, but not certified for use with P0926KE, P0926KH, P0924RT, P0923LR, RH100JX, or RH101KF baseplates |
| RoHS Compliance | Complies with European Recast RoHS Directive 2011/65/EU |
📦 Ordering Information
| Field | Details |
|---|---|
| Part Number | P0916RB (superseded by RH916RB) |
| Replacement Part | RH916RB (current Fieldbus Baseplate Terminator) |
| Associated Baseplates | FBM-supporting baseplates (RH926KE, RH926HM, RH926HT, etc.), FCP270 baseplates (P0926HC, P0926HW), FCP280 baseplates (RH924YL), excluding RH100JX for 100 Series FBMs |
| Installation Requirement | Used in systems without Time Strobe or A/B fieldbus splitting needs |