Skip to product information
1 of 5

Foxboro P0916QD Redundant Adapter

Foxboro P0916QD Redundant Adapter

  • Manufacturer: Foxboro

  • Product No.: P0916QD

  • Condition:1000 in stock

  • Product Type: Redundant Adapter

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Parameters for P0916QD Redundant Adapter

📘 Product Overview

Field Details
Manufacturer Foxboro (by Schneider Electric)
Part Number P0916QD
Product Type Redundant Adapter for FBM237 0 to 20 mA Output Module
Function Connects a redundant pair of FBM237 modules to a single termination assembly, enabling fault-tolerant operation of eight 0-20 mA analog output channels
Associated Module FBM237 (P0914XS)
System Compatibility Foxboro Evo Process Automation System, Standard 200 Series Subsystem

⚙️ Functional Specifications

Feature Specification
Role Facilitates redundant operation by connecting two FBM237 modules to a single TA, ensuring continuous output during module failure or replacement
Output Channels Supported Eight 0-20 mA dc analog output channels (per FBM237 pair)
Redundancy Mechanism Diode OR’d transmitter power from each FBM237 module to ensure redundant power supply to field devices; faulty module outputs driven to 0 mA, allowing the healthy module to maintain output
Connector Type Interfaces with two adjacent baseplate termination cable connectors (odd/even positions: 1-2, 3-4, 5-6, or 7-8) and outputs to a single 25-pin male D-subminiature termination cable
Compatible TAs P0916QC (PVC, compression), P0916YE (PA, compression), P0916QC (PVC, ring lug), P0917QZ (PVC, compression with bypass jacks)
Compatible Cables Type 1 cables: P/PVC (P0916DA, P0916DB, P0931RM, P0916DC, P0916DD, P0916DE, P0916DF, P0916DG, P0916DH, P0916DJ for 0.5 to 30 m); LSZH (P0928AA, P0928AB, P0928AC, P0928AD, P0928AE, P0928AF, P0928AG, P0928AH, P0928AJ, P0928AK for 0.5 to 30 m); H/XLPE (P0916VA to P0916VJ, 0.5 to 30 m, no longer available)
Signal Integrity Maintains galvanic isolation between channels (except between redundant pair outputs, which share a common field I/O connector) and supports HART protocol compatibility
Fail-Safe Operation Supports AOUTR function block for redundant output writes; configurable fail-safe options (Hold/Fallback, 0 mA fallback per channel, Fieldbus Fail-Safe Enable, and Delay Time)
Certification Type Inherits TA certifications: Type 1 (UL/UL-C Class I, Div 2, Groups A-D, T4; DEMKO Ex nA IIC T4 for Zone 2), Type 2 (non-incendive field circuits), Type 4 (Class 2 limited energy for P0917QZ), Type 5 (non-hazardous for P0917QZ)

🔌 Physical Specifications

Feature Specification
Material Not explicitly specified (likely polyamide or similar, based on TA materials)
Weight Not specified (typically lightweight, <100 g, as a passive adapter)
Dimensions Not specified (designed to fit adjacent baseplate connectors; compact to align with 45 mm FBM237 width)
Mounting Attaches to two adjacent termination cable connectors on the modular baseplate (positions 1-2, 3-4, 5-6, or 7-8)
Cable Connection 25-pin male D-subminiature for connection to TA via Type 1 termination cable

🌡️ Environmental Specifications

Parameter Specification
Operating Temperature Inferred from TA and FBM237: -20 to +70°C (-4 to +158°F) for PA TAs; -20 to +50°C (-4 to +122°F) for PVC TAs
Storage Temperature -40 to +70°C (-40 to +158°F) (aligned with FBM237 storage conditions)
Relative Humidity 5 to 95% (non-condensing)
Altitude (Operating) -300 to +3,000 m (-1,000 to +10,000 ft)
Altitude (Storage) -300 to +12,000 m (-1,000 to +40,000 ft)
Contamination Class G3 (harsh) per ISA S71.04, tested per EIA 364-65, Class III
Vibration 7.5 m/s² (5 to 500 Hz)

✅ Regulatory Compliance

Standard Details
Electromagnetic Compatibility (EMC) Inferred from FBM237: Meets European EMC Directive 89/336/EEC, EN 50081-2 (emission), EN 50082-2 (immunity), EN 61326 Annex A (industrial levels), CISPR 11 Class A; IEC 61000-4-2 (ESD: 4 kV contact, 8 kV air), IEC 61000-4-3 (radiated: 10 V/m), IEC 61000-4-4 (EFT: 2 kV), IEC 61000-4-5 (surge: 1-2 kV), IEC 61000-4-6 (conducted: 10 V rms), IEC 61000-4-8 (magnetic: 30 A/m)
Product Safety (UL) UL/UL-C listed for Class I, Groups A-D, Division 2, T4 when connected to specified Foxboro Evo processor modules per B0400FA; supports Class 2 limited energy circuits (60 V DC, 30 V AC, 100 VA or less)
Product Safety (Europe) CENELEC (DEMKO) certified Ex nA IIC T4 for Zone 2 when connected per B0400FA; supports non-incendive field circuits for Zone 2, Group IIC
Certification Notes P0917QZ TA (with bypass jacks) is limited to Type 4 (Class 2) and Type 5 (non-hazardous) certifications, affecting P0916QD when used with this TA

📦 Ordering Information

Field Details
Part Number P0916QD
Associated Module FBM237 (P0914XS)
Compatible TAs P0916QC (PVC, compression or ring lug), P0916YE (PA, compression), P0917QZ (PVC, compression with bypass jacks)
Compatible Cables Type 1 (P/PVC, LSZH, or H/XLPE; see Functional Specifications for part numbers)
Baseplate Requirement Standard 200 Series modular baseplate, with redundant FBM237s in adjacent odd/even positions (1-2, 3-4, 5-6, or 7-8)
View full details

Product Description

Product Parameters for P0916QD Redundant Adapter

📘 Product Overview

Field Details
Manufacturer Foxboro (by Schneider Electric)
Part Number P0916QD
Product Type Redundant Adapter for FBM237 0 to 20 mA Output Module
Function Connects a redundant pair of FBM237 modules to a single termination assembly, enabling fault-tolerant operation of eight 0-20 mA analog output channels
Associated Module FBM237 (P0914XS)
System Compatibility Foxboro Evo Process Automation System, Standard 200 Series Subsystem

⚙️ Functional Specifications

Feature Specification
Role Facilitates redundant operation by connecting two FBM237 modules to a single TA, ensuring continuous output during module failure or replacement
Output Channels Supported Eight 0-20 mA dc analog output channels (per FBM237 pair)
Redundancy Mechanism Diode OR’d transmitter power from each FBM237 module to ensure redundant power supply to field devices; faulty module outputs driven to 0 mA, allowing the healthy module to maintain output
Connector Type Interfaces with two adjacent baseplate termination cable connectors (odd/even positions: 1-2, 3-4, 5-6, or 7-8) and outputs to a single 25-pin male D-subminiature termination cable
Compatible TAs P0916QC (PVC, compression), P0916YE (PA, compression), P0916QC (PVC, ring lug), P0917QZ (PVC, compression with bypass jacks)
Compatible Cables Type 1 cables: P/PVC (P0916DA, P0916DB, P0931RM, P0916DC, P0916DD, P0916DE, P0916DF, P0916DG, P0916DH, P0916DJ for 0.5 to 30 m); LSZH (P0928AA, P0928AB, P0928AC, P0928AD, P0928AE, P0928AF, P0928AG, P0928AH, P0928AJ, P0928AK for 0.5 to 30 m); H/XLPE (P0916VA to P0916VJ, 0.5 to 30 m, no longer available)
Signal Integrity Maintains galvanic isolation between channels (except between redundant pair outputs, which share a common field I/O connector) and supports HART protocol compatibility
Fail-Safe Operation Supports AOUTR function block for redundant output writes; configurable fail-safe options (Hold/Fallback, 0 mA fallback per channel, Fieldbus Fail-Safe Enable, and Delay Time)
Certification Type Inherits TA certifications: Type 1 (UL/UL-C Class I, Div 2, Groups A-D, T4; DEMKO Ex nA IIC T4 for Zone 2), Type 2 (non-incendive field circuits), Type 4 (Class 2 limited energy for P0917QZ), Type 5 (non-hazardous for P0917QZ)

🔌 Physical Specifications

Feature Specification
Material Not explicitly specified (likely polyamide or similar, based on TA materials)
Weight Not specified (typically lightweight, <100 g, as a passive adapter)
Dimensions Not specified (designed to fit adjacent baseplate connectors; compact to align with 45 mm FBM237 width)
Mounting Attaches to two adjacent termination cable connectors on the modular baseplate (positions 1-2, 3-4, 5-6, or 7-8)
Cable Connection 25-pin male D-subminiature for connection to TA via Type 1 termination cable

🌡️ Environmental Specifications

Parameter Specification
Operating Temperature Inferred from TA and FBM237: -20 to +70°C (-4 to +158°F) for PA TAs; -20 to +50°C (-4 to +122°F) for PVC TAs
Storage Temperature -40 to +70°C (-40 to +158°F) (aligned with FBM237 storage conditions)
Relative Humidity 5 to 95% (non-condensing)
Altitude (Operating) -300 to +3,000 m (-1,000 to +10,000 ft)
Altitude (Storage) -300 to +12,000 m (-1,000 to +40,000 ft)
Contamination Class G3 (harsh) per ISA S71.04, tested per EIA 364-65, Class III
Vibration 7.5 m/s² (5 to 500 Hz)

✅ Regulatory Compliance

Standard Details
Electromagnetic Compatibility (EMC) Inferred from FBM237: Meets European EMC Directive 89/336/EEC, EN 50081-2 (emission), EN 50082-2 (immunity), EN 61326 Annex A (industrial levels), CISPR 11 Class A; IEC 61000-4-2 (ESD: 4 kV contact, 8 kV air), IEC 61000-4-3 (radiated: 10 V/m), IEC 61000-4-4 (EFT: 2 kV), IEC 61000-4-5 (surge: 1-2 kV), IEC 61000-4-6 (conducted: 10 V rms), IEC 61000-4-8 (magnetic: 30 A/m)
Product Safety (UL) UL/UL-C listed for Class I, Groups A-D, Division 2, T4 when connected to specified Foxboro Evo processor modules per B0400FA; supports Class 2 limited energy circuits (60 V DC, 30 V AC, 100 VA or less)
Product Safety (Europe) CENELEC (DEMKO) certified Ex nA IIC T4 for Zone 2 when connected per B0400FA; supports non-incendive field circuits for Zone 2, Group IIC
Certification Notes P0917QZ TA (with bypass jacks) is limited to Type 4 (Class 2) and Type 5 (non-hazardous) certifications, affecting P0916QD when used with this TA

📦 Ordering Information

Field Details
Part Number P0916QD
Associated Module FBM237 (P0914XS)
Compatible TAs P0916QC (PVC, compression or ring lug), P0916YE (PA, compression), P0917QZ (PVC, compression with bypass jacks)
Compatible Cables Type 1 (P/PVC, LSZH, or H/XLPE; see Functional Specifications for part numbers)
Baseplate Requirement Standard 200 Series modular baseplate, with redundant FBM237s in adjacent odd/even positions (1-2, 3-4, 5-6, or 7-8)

Download PDF file here:

Click to Download PDF

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)