Skip to product information
1 of 9

Foxboro FBM204 RH914SY 0 to 20 mA I/O Module

Foxboro FBM204 RH914SY 0 to 20 mA I/O Module

  • Manufacturer: Foxboro

  • Product No.: FBM204 RH914SY

  • Condition:1000 in stock

  • Product Type: 0 to 20 mA I/O Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

📘 Product Overview

Field Details
Manufacturer Schneider Electric (Foxboro)
Model Number FBM204 RH914SY
Product Type 0 to 20 mA I/O Module
Function Provides four 20 mA dc analog input channels and four 20 mA dc analog output channels
System Compatibility Interfaces with Foxboro DCS via redundant 2 Mbps module Fieldbus; compatible with 200 Series baseplates and 100 Series upgrades
Included Components FBM204 module; requires separate Termination Assembly (TA) and cables

⚙️ Hardware Specifications

Feature Specification
Input Channels 4 isolated and independent 20 mA dc analog input channels
Output Channels 4 isolated and independent 20 mA dc analog output channels
Input/Output Range 0 to 20.4 mA dc (nominal)
Input Accuracy ±0.03% of span (includes linearity)
Output Accuracy ±0.03% of span (includes linearity)
Accuracy Temperature Coefficient ±50 ppm/°C
Input Signal A/D Conversion Independent Sigma-Delta converter per channel (new reading every 25 ms)
Input Channel Impedance 61.5 Ω nominal
Integration Period Software configurable
Common Mode Rejection >100 dB at 50 or 60 Hz
Normal Mode Rejection >95 dB at 50 or 60 Hz
Output Load 750 Ω maximum
Output Processing Delay 30 ms maximum
Output Resolution 13 bits
Input Channel Isolation Galvanically isolated; withstands 600 V AC for 1 minute (not for permanent connection)
Loop Power Supply Protection (Input) Galvanically isolated, current limited (<30 mA, ~100 mA if shorted), voltage regulated
Loop Power Supply Protection (Output) Galvanically isolated, current limited (~25 mA, up to 35 mA if FET shorts), voltage regulated
Field Device Cabling Distance (Input) Depends on compliance voltage (20.2 V dc at 20.4 mA), wire gauge, and field device voltage drop
Field Device Cabling Distance (Output) Depends on compliance voltage (19.6 V dc at 20.4 mA), wire gauge, and field device voltage drop
HART Compatibility Electrically compatible with standard HART signals; requires 200 Ω in-line resistor (RH902VY) for FoxCom/HART transmitters
Visual Indicators Red and green LEDs for module status
Construction Rugged extruded aluminum exterior

🔌 Power Requirements

Feature Specification
Input Voltage Range (Redundant) 24 V DC +5%, -10%
Consumption 7 W (maximum)
Heat Dissipation 3.5 W (maximum)

🌡️ Environmental Specifications

Parameter Specification
Operating Temperature Module and TA (PA): -20 to +70°C (-4 to +158°F)
Storage Temperature -20 to +70°C (-4 to +158°F)
Relative Humidity 5 to 95% (non-condensing)
Altitude (Operating) -300 to +3,000 m (-1,000 to +10,000 ft)
Altitude (Storage) -300 to +12,000 m (-1,000 to +40,000 ft)
Vibration 7.5 m/s² (0.75 g) from 5 to 500 Hz
Contamination Class G3 (harsh) per ISA S71.04, tested per EIA 364-65, Class III

✅ Regulatory Compliance

Standard Details
EMC European EMC Directive 2004/108/EC (pre-Apr 2016), 2014/30/EU (post-Apr 2016); EN61326-1:2013 Class A Emissions, Industrial Immunity
Product Safety (UL) UL/UL-C listed for Class I, Groups A-D, Division 2, T4; Class 2 per NEC (NFPA No.70) and CSA C22.1
Product Safety (Europe) Low Voltage Directive 2006/95/EC (pre-Apr 2016), 2014/35/EU (post-Apr 2016); ATEX 94/9/EC (pre-Apr 2016), 2014/34/EU (post-Apr 2016); DEMKO Ex nA IIC T4 for Zone 2 (except TA RH917QW)
RoHS Compliance Complies with European RoHS Directive 2011/65/EU, including 2015/863, 2017/2102
Marine Certification ABS Type Approved; Bureau Veritas certified for Environmental Category EC31

🛠️ Installation & Configuration

Feature Details
Mounting Mounts on DIN rail or 19-inch rack modular baseplate (4 or 8 FBMs); supports 100 Series conversion structures
Termination Assemblies DIN rail-mounted: compression (PA: RH916XK, RH917QW), ring lug (PVC: P0916AH)
Auto-Detection Communicates via redundant 2 Mbps Fieldbus; auto-switches to active path
Configuration Analog I/O application program with configurable Conversion Time, Fail-Safe (Hold/Fallback), and Output Fail-Safe Fallback Data; supports DPIDA control blocks
Calibration Not required
Removal/Replacement Can be removed/replaced without disconnecting field wiring, power, or communication cables

📡 Termination Assemblies and Cables

Feature Specification
TA Types Compression (PA: RH916XK, RH917QW); Ring Lug (PVC: P0916AH)
TA Features RH917QW includes bypass jacks for output channels (compatible with Foxboro P0900HJ Output Bypass Station)
TA Wiring (Compression) Solid/Stranded: 0.2 to 4 mm² / 0.2 to 2.5 mm² (24 to 12 AWG); Ferrules: 0.2 to 2.5 mm²
TA Wiring (Ring Lug) #6 connectors (0.375 in); 0.5 to 4 mm² (22 to 12 AWG)
TA Certification Type 1 (RH916XK, P0916AH): UL/UL-C Class I, Div 2, T4; DEMKO Ex nA IIC T4 (Zone 2); Type 4/5 (RH917QW): Class 2 limited energy, non-hazardous locations only
Cable Types Type 1 (P/PVC: -20 to +80°C; LSZH: -40 to +105°C)
Cable Lengths Up to 30 m (98 ft)
Cable Connectors Baseplate: 37-pin D-sub; TA: 25-pin D-sub
Example Cable Part Numbers 2.0 m: RH931RM (P/PVC), RH928AC (LSZH); 3.0 m: RH916DC (P/PVC), RH928AD (LSZH); 30 m: RH916DJ (P/PVC), RH928AK (LSZH)

🔧 Functional Specifications

Feature Details
Input Signal Accepts 4 to 20 mA transmitters or self-powered 20 mA sources
Output Signal Drives external loads with 0 to 20 mA output
Process I/O Communications Redundant 2 Mbps Fieldbus with FCM or FCP; auto-switches to active path
100 Series Upgrade Replaces 100 Series FBM04; supports TA or Termination Assembly Adapter (TAA) for existing wiring

📦 Ordering Information

Field Details
Grade Industrial
Model Number FBM204 (RH914SY)
Includes FBM204 module (TA and cables ordered separately)
TA Part Numbers Compression: RH916XK, RH917QW; Ring Lug: P0916AH
View full details

Product Description

📘 Product Overview

Field Details
Manufacturer Schneider Electric (Foxboro)
Model Number FBM204 RH914SY
Product Type 0 to 20 mA I/O Module
Function Provides four 20 mA dc analog input channels and four 20 mA dc analog output channels
System Compatibility Interfaces with Foxboro DCS via redundant 2 Mbps module Fieldbus; compatible with 200 Series baseplates and 100 Series upgrades
Included Components FBM204 module; requires separate Termination Assembly (TA) and cables

⚙️ Hardware Specifications

Feature Specification
Input Channels 4 isolated and independent 20 mA dc analog input channels
Output Channels 4 isolated and independent 20 mA dc analog output channels
Input/Output Range 0 to 20.4 mA dc (nominal)
Input Accuracy ±0.03% of span (includes linearity)
Output Accuracy ±0.03% of span (includes linearity)
Accuracy Temperature Coefficient ±50 ppm/°C
Input Signal A/D Conversion Independent Sigma-Delta converter per channel (new reading every 25 ms)
Input Channel Impedance 61.5 Ω nominal
Integration Period Software configurable
Common Mode Rejection >100 dB at 50 or 60 Hz
Normal Mode Rejection >95 dB at 50 or 60 Hz
Output Load 750 Ω maximum
Output Processing Delay 30 ms maximum
Output Resolution 13 bits
Input Channel Isolation Galvanically isolated; withstands 600 V AC for 1 minute (not for permanent connection)
Loop Power Supply Protection (Input) Galvanically isolated, current limited (<30 mA, ~100 mA if shorted), voltage regulated
Loop Power Supply Protection (Output) Galvanically isolated, current limited (~25 mA, up to 35 mA if FET shorts), voltage regulated
Field Device Cabling Distance (Input) Depends on compliance voltage (20.2 V dc at 20.4 mA), wire gauge, and field device voltage drop
Field Device Cabling Distance (Output) Depends on compliance voltage (19.6 V dc at 20.4 mA), wire gauge, and field device voltage drop
HART Compatibility Electrically compatible with standard HART signals; requires 200 Ω in-line resistor (RH902VY) for FoxCom/HART transmitters
Visual Indicators Red and green LEDs for module status
Construction Rugged extruded aluminum exterior

🔌 Power Requirements

Feature Specification
Input Voltage Range (Redundant) 24 V DC +5%, -10%
Consumption 7 W (maximum)
Heat Dissipation 3.5 W (maximum)

🌡️ Environmental Specifications

Parameter Specification
Operating Temperature Module and TA (PA): -20 to +70°C (-4 to +158°F)
Storage Temperature -20 to +70°C (-4 to +158°F)
Relative Humidity 5 to 95% (non-condensing)
Altitude (Operating) -300 to +3,000 m (-1,000 to +10,000 ft)
Altitude (Storage) -300 to +12,000 m (-1,000 to +40,000 ft)
Vibration 7.5 m/s² (0.75 g) from 5 to 500 Hz
Contamination Class G3 (harsh) per ISA S71.04, tested per EIA 364-65, Class III

✅ Regulatory Compliance

Standard Details
EMC European EMC Directive 2004/108/EC (pre-Apr 2016), 2014/30/EU (post-Apr 2016); EN61326-1:2013 Class A Emissions, Industrial Immunity
Product Safety (UL) UL/UL-C listed for Class I, Groups A-D, Division 2, T4; Class 2 per NEC (NFPA No.70) and CSA C22.1
Product Safety (Europe) Low Voltage Directive 2006/95/EC (pre-Apr 2016), 2014/35/EU (post-Apr 2016); ATEX 94/9/EC (pre-Apr 2016), 2014/34/EU (post-Apr 2016); DEMKO Ex nA IIC T4 for Zone 2 (except TA RH917QW)
RoHS Compliance Complies with European RoHS Directive 2011/65/EU, including 2015/863, 2017/2102
Marine Certification ABS Type Approved; Bureau Veritas certified for Environmental Category EC31

🛠️ Installation & Configuration

Feature Details
Mounting Mounts on DIN rail or 19-inch rack modular baseplate (4 or 8 FBMs); supports 100 Series conversion structures
Termination Assemblies DIN rail-mounted: compression (PA: RH916XK, RH917QW), ring lug (PVC: P0916AH)
Auto-Detection Communicates via redundant 2 Mbps Fieldbus; auto-switches to active path
Configuration Analog I/O application program with configurable Conversion Time, Fail-Safe (Hold/Fallback), and Output Fail-Safe Fallback Data; supports DPIDA control blocks
Calibration Not required
Removal/Replacement Can be removed/replaced without disconnecting field wiring, power, or communication cables

📡 Termination Assemblies and Cables

Feature Specification
TA Types Compression (PA: RH916XK, RH917QW); Ring Lug (PVC: P0916AH)
TA Features RH917QW includes bypass jacks for output channels (compatible with Foxboro P0900HJ Output Bypass Station)
TA Wiring (Compression) Solid/Stranded: 0.2 to 4 mm² / 0.2 to 2.5 mm² (24 to 12 AWG); Ferrules: 0.2 to 2.5 mm²
TA Wiring (Ring Lug) #6 connectors (0.375 in); 0.5 to 4 mm² (22 to 12 AWG)
TA Certification Type 1 (RH916XK, P0916AH): UL/UL-C Class I, Div 2, T4; DEMKO Ex nA IIC T4 (Zone 2); Type 4/5 (RH917QW): Class 2 limited energy, non-hazardous locations only
Cable Types Type 1 (P/PVC: -20 to +80°C; LSZH: -40 to +105°C)
Cable Lengths Up to 30 m (98 ft)
Cable Connectors Baseplate: 37-pin D-sub; TA: 25-pin D-sub
Example Cable Part Numbers 2.0 m: RH931RM (P/PVC), RH928AC (LSZH); 3.0 m: RH916DC (P/PVC), RH928AD (LSZH); 30 m: RH916DJ (P/PVC), RH928AK (LSZH)

🔧 Functional Specifications

Feature Details
Input Signal Accepts 4 to 20 mA transmitters or self-powered 20 mA sources
Output Signal Drives external loads with 0 to 20 mA output
Process I/O Communications Redundant 2 Mbps Fieldbus with FCM or FCP; auto-switches to active path
100 Series Upgrade Replaces 100 Series FBM04; supports TA or Termination Assembly Adapter (TAA) for existing wiring

📦 Ordering Information

Field Details
Grade Industrial
Model Number FBM204 (RH914SY)
Includes FBM204 module (TA and cables ordered separately)
TA Part Numbers Compression: RH916XK, RH917QW; Ring Lug: P0916AH

Download PDF file here:

Click to Download PDF

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)