📘 Product Overview

Field Details
Manufacturer Invensys (Foxboro, now Schneider Electric)
Model Number 873RS-AIYFNZ-7
Product Type Electrochemical Analyzer for Resistivity Measurements
Function Measures resistivity of aqueous solutions with automatic temperature compensation
System Compatibility Compatible with 871CC sensors (0.1 cm⁻¹ cell factor); supports single or dual sensor setups
Included Components Analyzer unit, optional rear cover (BS805QK for plastic enclosure)

⚙️ Hardware Specifications

Feature Specification
Enclosure Type Metal (NEMA 4X, CSA Enclosure 4X, IP-65), movable surface mount (Z option)
Dimensions 92(H) × 92(W) × 259(L) mm (3.6 × 3.6 × 10.1 in)
Weight 3.13 kg (6.9 lb) for movable surface mount
Display Four-digit red LED (14.2 mm height), visible up to 6 m (20 ft)
Keypad 8 keys (6 dual-function); includes Shift, Abso, Temp, Enter, etc.
Sensor Inputs Dual sensor inputs (Cell 1 and Cell 2)
Memory Non-volatile EEPROM for operating parameters and calibration data

🔌 Electrical Specifications

Feature Specification
Supply Voltage 120 V AC (A option)
Supply Frequency 50 or 60 Hz, ±3 Hz
Analog Outputs Two isolated outputs: 4–20 mA (I option); Output #1 and #2 configurable
Alarm Contacts Two Form C contacts, 5 A noninductive, 125 V AC/30 V DC (min 1 A)
Output Isolation Isolated, powered outputs
RFI Susceptibility Compliant with European EMC Directive 89/336/EEC when cables are in grounded conduit

📏 Measurement Specifications

Feature Specification
Measurement Ranges 0–2.000, 0–5.000, 0–10.00, 0–20.00 MΩ·cm
Display Units MΩ·cm or % (for ratio or % rejection)
Temperature Range Measurement: -17 to +150 °C (0 to 302 °F); Compensation: 0 to 120 °C (32 to 248 °F)
Accuracy ±0.5% of full-scale range at 25 °C
Response Time 3 s for 90% change (single sensor, no damping); 7 s (dual sensor)
Damping Configurable: 0, 10, 20, 40, 80, 160 s

🔧 Configuration and Calibration

Feature Details
Configuration Mode Allows setting measurement range, alarms, diagnostics, and output characterization
Security User-configurable security code (default: 0800)
Calibration Electronic bench calibration; sensor-specific calibration with tCF and CF
Sensor Compatibility 871CC sensors (A2–F2: 100 kΩ thermistor; K2–M2: Pt 100 RTD)
Cell Factor (CF) Factory default: 0.1000 cm⁻¹; adjustable for specific sensor
Temperature Compensation Ultrapure water correction referenced to 25 °C or absolute (no compensation)

🌡️ Environmental Specifications

Parameter Specification
Operating Temperature -25 to +55 °C (-13 to +131 °F)
Storage Temperature Not specified in document
Relative Humidity 5 to 95%, non-condensing
Protection Rating NEMA 4X, CSA Enclosure 4X, IEC IP-65 (metal enclosure)

✅ Certifications

Standard Details
FM General purpose (FGZ); Nonincendive Class I, II, Div. 2, Groups A–D, F, G, T6
CSA (Canada) Class I, Div. 2, Groups A–D, T6 (for 24 V, 100 V, 120 V AC)
EMC Complies with European EMC Directive 89/336/EEC (with proper cable conduit)
RoHS/WEEE Exempt from RoHS Directive; complies with WEEE Directive

🛠️ Installation

Feature Details
Mounting Options Movable surface mount (Z); also supports panel, pipe, fixed surface (metal only)
Wiring Sensor, power, and alarm wires to TB1, TB2, TB3, TB4; separate conduits for sensor/output and power/alarms
Conduit Requirements 1/2-inch rigid metal or semi-rigid plastic; specific fittings (e.g., T&B #370)
Grounding Outer electrode (green wire) must be grounded for high-voltage solutions

🚨 Alarms and Diagnostics

Feature Details
Alarms Two configurable alarms (HAC, LAC); set points adjustable 0 to full scale
Alarm Timers Trigger, feed, delay timers (0–99 min, 0–9 tenths/hundredths)
Hysteresis 0–99% of full scale, configurable
Error Codes Er 1 (instrument fault), Er 2 (temp error), Er 3 (range error), Er 4 (calibration error)
Diagnostics Troubleshooting for noisy signals, incorrect readings, gas bubbles, etc.

📦 Ordering Information

Field Details
Model Number 873RS-AIYFNZ-7
Code Breakdown A: 120 V AC; I: 4–20 mA outputs; Y: Pipe mount; F: Optional feature; NZ: Movable surface mount; -7: Additional options (not detailed in document)
Accessories Optional storm door, resistor kit for calibration, rear cover (plastic enclosure)

View full details

Product Description


📘 Product Overview

Field Details
Manufacturer Invensys (Foxboro, now Schneider Electric)
Model Number 873RS-AIYFNZ-7
Product Type Electrochemical Analyzer for Resistivity Measurements
Function Measures resistivity of aqueous solutions with automatic temperature compensation
System Compatibility Compatible with 871CC sensors (0.1 cm⁻¹ cell factor); supports single or dual sensor setups
Included Components Analyzer unit, optional rear cover (BS805QK for plastic enclosure)

⚙️ Hardware Specifications

Feature Specification
Enclosure Type Metal (NEMA 4X, CSA Enclosure 4X, IP-65), movable surface mount (Z option)
Dimensions 92(H) × 92(W) × 259(L) mm (3.6 × 3.6 × 10.1 in)
Weight 3.13 kg (6.9 lb) for movable surface mount
Display Four-digit red LED (14.2 mm height), visible up to 6 m (20 ft)
Keypad 8 keys (6 dual-function); includes Shift, Abso, Temp, Enter, etc.
Sensor Inputs Dual sensor inputs (Cell 1 and Cell 2)
Memory Non-volatile EEPROM for operating parameters and calibration data

🔌 Electrical Specifications

Feature Specification
Supply Voltage 120 V AC (A option)
Supply Frequency 50 or 60 Hz, ±3 Hz
Analog Outputs Two isolated outputs: 4–20 mA (I option); Output #1 and #2 configurable
Alarm Contacts Two Form C contacts, 5 A noninductive, 125 V AC/30 V DC (min 1 A)
Output Isolation Isolated, powered outputs
RFI Susceptibility Compliant with European EMC Directive 89/336/EEC when cables are in grounded conduit

📏 Measurement Specifications

Feature Specification
Measurement Ranges 0–2.000, 0–5.000, 0–10.00, 0–20.00 MΩ·cm
Display Units MΩ·cm or % (for ratio or % rejection)
Temperature Range Measurement: -17 to +150 °C (0 to 302 °F); Compensation: 0 to 120 °C (32 to 248 °F)
Accuracy ±0.5% of full-scale range at 25 °C
Response Time 3 s for 90% change (single sensor, no damping); 7 s (dual sensor)
Damping Configurable: 0, 10, 20, 40, 80, 160 s

🔧 Configuration and Calibration

Feature Details
Configuration Mode Allows setting measurement range, alarms, diagnostics, and output characterization
Security User-configurable security code (default: 0800)
Calibration Electronic bench calibration; sensor-specific calibration with tCF and CF
Sensor Compatibility 871CC sensors (A2–F2: 100 kΩ thermistor; K2–M2: Pt 100 RTD)
Cell Factor (CF) Factory default: 0.1000 cm⁻¹; adjustable for specific sensor
Temperature Compensation Ultrapure water correction referenced to 25 °C or absolute (no compensation)

🌡️ Environmental Specifications

Parameter Specification
Operating Temperature -25 to +55 °C (-13 to +131 °F)
Storage Temperature Not specified in document
Relative Humidity 5 to 95%, non-condensing
Protection Rating NEMA 4X, CSA Enclosure 4X, IEC IP-65 (metal enclosure)

✅ Certifications

Standard Details
FM General purpose (FGZ); Nonincendive Class I, II, Div. 2, Groups A–D, F, G, T6
CSA (Canada) Class I, Div. 2, Groups A–D, T6 (for 24 V, 100 V, 120 V AC)
EMC Complies with European EMC Directive 89/336/EEC (with proper cable conduit)
RoHS/WEEE Exempt from RoHS Directive; complies with WEEE Directive

🛠️ Installation

Feature Details
Mounting Options Movable surface mount (Z); also supports panel, pipe, fixed surface (metal only)
Wiring Sensor, power, and alarm wires to TB1, TB2, TB3, TB4; separate conduits for sensor/output and power/alarms
Conduit Requirements 1/2-inch rigid metal or semi-rigid plastic; specific fittings (e.g., T&B #370)
Grounding Outer electrode (green wire) must be grounded for high-voltage solutions

🚨 Alarms and Diagnostics

Feature Details
Alarms Two configurable alarms (HAC, LAC); set points adjustable 0 to full scale
Alarm Timers Trigger, feed, delay timers (0–99 min, 0–9 tenths/hundredths)
Hysteresis 0–99% of full scale, configurable
Error Codes Er 1 (instrument fault), Er 2 (temp error), Er 3 (range error), Er 4 (calibration error)
Diagnostics Troubleshooting for noisy signals, incorrect readings, gas bubbles, etc.

📦 Ordering Information

Field Details
Model Number 873RS-AIYFNZ-7
Code Breakdown A: 120 V AC; I: 4–20 mA outputs; Y: Pipe mount; F: Optional feature; NZ: Movable surface mount; -7: Additional options (not detailed in document)
Accessories Optional storm door, resistor kit for calibration, rear cover (plastic enclosure)