Skip to product information
1 of 3

Emerson VE4050S2K1C0 DeltaV 8-Wide I/O Carrier Module

Emerson VE4050S2K1C0 DeltaV 8-Wide I/O Carrier Module

  • Manufacturer: Emerson

  • Product No.: VE4003S2B3

  • Condition:1000 in stock

  • Product Type: DeltaV M-series Analog Input Module

  • Product Origin: 6954789056789

  • Payment: T/T, Western Union

  • Weight: 400g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Emerson VE4050S2K1C0 DeltaV 8-Wide I/O Carrier Module

The Emerson VE4050S2K1C0 represents the backbone of high-density DeltaV M-series I/O subsystems, providing a robust 8-slot carrier platform for analog input, analog output, discrete I/O, and specialty communication modules. Engineered for mission-critical process control applications, this carrier delivers redundant power distribution, hot-swappable module replacement, and deterministic LocalBus communication for industries demanding maximum uptime and operational flexibility.

Why Choose the VE4050S2K1C0 for Your DeltaV System?

In modern process plants where every minute of downtime translates to lost production revenue, the VE4050S2K1C0 carrier module provides the foundation for fault-tolerant I/O architectures. Unlike traditional fixed-slot controllers, this modular carrier enables flexible I/O configuration tailored to specific process requirements while maintaining the ability to expand or reconfigure without system shutdown.

Real-World Impact: A major petrochemical facility upgraded from legacy 4-slot carriers to VE4050S2K1C0 8-wide carriers, reducing cabinet footprint by 40% while increasing I/O density from 128 to 256 points per controller. The hot-swap capability enabled module replacement during production runs, eliminating 12 planned shutdown events annually and saving an estimated $2.4M in lost production costs.

Core Technical Specifications

I/O Slot Capacity 8 independent module slots
Supported Modules VE4001-VE4070 series I/O cards, communication interfaces
LocalBus Architecture Deterministic backplane with <10ms scan cycle
Power Distribution Redundant 24 VDC with automatic failover
Power Capacity 120W total (15W per slot average)
Hot-Swap Support All I/O modules replaceable under power
Mounting DIN rail or panel mount (horizontal/vertical orientation)
Dimensions 450mm (W) x 180mm (H) x 120mm (D)
Operating Temperature -40°C to +70°C ambient
Humidity Range 5-95% RH non-condensing
Vibration Resistance IEC 60068-2-6 compliant (2g, 10-150 Hz)
EMC Compliance CE marked, EN 61000-6-2/4
Hazardous Area Suitable for Zone 2/Class I Div 2 installations

Modular I/O Configuration Flexibility

The VE4050S2K1C0 accepts any combination of DeltaV M-series I/O modules, enabling customized configurations for diverse process requirements:

Analog I/O: VE4003 (8-ch AI), VE4004 (8-ch AO), VE4033 (redundant AI), VE4035 (redundant AO) for precision process measurement and control with HART communication.

Discrete I/O: VE4001 (32-ch DI), VE4002 (32-ch DO), VE4031 (redundant DI), VE4032 (redundant DO) for on/off control, status monitoring, and safety interlocks.

Specialty Modules: VE4011 (FOUNDATION Fieldbus H1), VE4006 (serial RS-232/485), VE4013 (Profibus DP) for integration with smart field devices and third-party systems.

Redundant Power Architecture

Dual 24 VDC power inputs with diode-OR isolation ensure continuous operation during power supply failures or maintenance activities. Automatic load balancing distributes current across both supplies, while individual slot monitoring detects overcurrent conditions and isolates faulted modules without affecting adjacent slots. Green LED indicators provide at-a-glance power status verification during commissioning and troubleshooting.

Power budget management tools within DeltaV Explorer calculate total consumption across all installed modules, flagging configurations that exceed carrier capacity before deployment. This proactive validation prevents field failures and ensures reliable long-term operation.

Hot-Swap Maintenance Advantages

Every I/O module slot supports hot-swap replacement, enabling technicians to replace failed or upgraded modules without process interruption. The carrier's keyed connectors prevent incorrect module insertion, while automatic module discovery and configuration download from the controller eliminates manual setup after replacement.

Maintenance Scenario: During a routine inspection, diagnostics flagged a degrading analog input module with increasing noise levels. Maintenance personnel ordered a replacement module, which arrived pre-configured with the existing channel assignments. During normal production, the technician removed the failing module and inserted the replacement—total downtime: zero seconds. The controller automatically recognized the new module, downloaded configuration parameters, and resumed normal operation within 5 seconds.

System Integration & Scalability

The VE4050S2K1C0 integrates with DeltaV M-series controllers (VE3005, VE3006, VE3007, VE3008) via shielded LocalBus cables supporting distances up to 100 meters between controller and I/O carriers. Multiple carriers can be daisy-chained to create distributed I/O architectures with up to 64 carriers per controller, supporting thousands of I/O points from a single control node.

Vertical and horizontal mounting options accommodate diverse cabinet layouts, while optional locking DIN rail clips ensure vibration-resistant installation in mobile equipment and offshore platforms. Cable management accessories route field wiring cleanly, maintaining separation between power and signal cables for optimal EMC performance.

Related DeltaV Carrier Products

Product Model Description Product Link
VE4050E1C0 DeltaV 8-Wide I/O Interface Carrier (Standard Version) View Product
VE4050S2K1C0 (Logic Solver) 8-Wide Logic Solver Horizontal Carrier for SIS Applications View Product
VE4050S2K1C0 Complete 8-Wide I/O Carrier with Terminal Block Assembly View Product

Quality Assurance & Lifecycle Support

Factory-tested to IEC 61131-2 industrial controller standards with full burn-in testing and environmental stress screening. Ships with installation guide, power budget calculator, and configuration templates for common I/O arrangements. Backed by 24-month warranty covering manufacturing defects and performance specifications.

Global technical support provides system design assistance, power budget validation, and troubleshooting guidance for complex distributed I/O architectures. Replacement carriers ship pre-tested and ready for installation, minimizing emergency repair downtime.

© 2025 INDUSTRIAL CONTROL HUB. All rights reserved.
Original Source: https://www.indctrlhub.com
Contact: sales@indctrlhub.com | +0086 18359243191

View full details

Product Description

Emerson VE4050S2K1C0 DeltaV 8-Wide I/O Carrier Module

The Emerson VE4050S2K1C0 represents the backbone of high-density DeltaV M-series I/O subsystems, providing a robust 8-slot carrier platform for analog input, analog output, discrete I/O, and specialty communication modules. Engineered for mission-critical process control applications, this carrier delivers redundant power distribution, hot-swappable module replacement, and deterministic LocalBus communication for industries demanding maximum uptime and operational flexibility.

Why Choose the VE4050S2K1C0 for Your DeltaV System?

In modern process plants where every minute of downtime translates to lost production revenue, the VE4050S2K1C0 carrier module provides the foundation for fault-tolerant I/O architectures. Unlike traditional fixed-slot controllers, this modular carrier enables flexible I/O configuration tailored to specific process requirements while maintaining the ability to expand or reconfigure without system shutdown.

Real-World Impact: A major petrochemical facility upgraded from legacy 4-slot carriers to VE4050S2K1C0 8-wide carriers, reducing cabinet footprint by 40% while increasing I/O density from 128 to 256 points per controller. The hot-swap capability enabled module replacement during production runs, eliminating 12 planned shutdown events annually and saving an estimated $2.4M in lost production costs.

Core Technical Specifications

I/O Slot Capacity 8 independent module slots
Supported Modules VE4001-VE4070 series I/O cards, communication interfaces
LocalBus Architecture Deterministic backplane with <10ms scan cycle
Power Distribution Redundant 24 VDC with automatic failover
Power Capacity 120W total (15W per slot average)
Hot-Swap Support All I/O modules replaceable under power
Mounting DIN rail or panel mount (horizontal/vertical orientation)
Dimensions 450mm (W) x 180mm (H) x 120mm (D)
Operating Temperature -40°C to +70°C ambient
Humidity Range 5-95% RH non-condensing
Vibration Resistance IEC 60068-2-6 compliant (2g, 10-150 Hz)
EMC Compliance CE marked, EN 61000-6-2/4
Hazardous Area Suitable for Zone 2/Class I Div 2 installations

Modular I/O Configuration Flexibility

The VE4050S2K1C0 accepts any combination of DeltaV M-series I/O modules, enabling customized configurations for diverse process requirements:

Analog I/O: VE4003 (8-ch AI), VE4004 (8-ch AO), VE4033 (redundant AI), VE4035 (redundant AO) for precision process measurement and control with HART communication.

Discrete I/O: VE4001 (32-ch DI), VE4002 (32-ch DO), VE4031 (redundant DI), VE4032 (redundant DO) for on/off control, status monitoring, and safety interlocks.

Specialty Modules: VE4011 (FOUNDATION Fieldbus H1), VE4006 (serial RS-232/485), VE4013 (Profibus DP) for integration with smart field devices and third-party systems.

Redundant Power Architecture

Dual 24 VDC power inputs with diode-OR isolation ensure continuous operation during power supply failures or maintenance activities. Automatic load balancing distributes current across both supplies, while individual slot monitoring detects overcurrent conditions and isolates faulted modules without affecting adjacent slots. Green LED indicators provide at-a-glance power status verification during commissioning and troubleshooting.

Power budget management tools within DeltaV Explorer calculate total consumption across all installed modules, flagging configurations that exceed carrier capacity before deployment. This proactive validation prevents field failures and ensures reliable long-term operation.

Hot-Swap Maintenance Advantages

Every I/O module slot supports hot-swap replacement, enabling technicians to replace failed or upgraded modules without process interruption. The carrier's keyed connectors prevent incorrect module insertion, while automatic module discovery and configuration download from the controller eliminates manual setup after replacement.

Maintenance Scenario: During a routine inspection, diagnostics flagged a degrading analog input module with increasing noise levels. Maintenance personnel ordered a replacement module, which arrived pre-configured with the existing channel assignments. During normal production, the technician removed the failing module and inserted the replacement—total downtime: zero seconds. The controller automatically recognized the new module, downloaded configuration parameters, and resumed normal operation within 5 seconds.

System Integration & Scalability

The VE4050S2K1C0 integrates with DeltaV M-series controllers (VE3005, VE3006, VE3007, VE3008) via shielded LocalBus cables supporting distances up to 100 meters between controller and I/O carriers. Multiple carriers can be daisy-chained to create distributed I/O architectures with up to 64 carriers per controller, supporting thousands of I/O points from a single control node.

Vertical and horizontal mounting options accommodate diverse cabinet layouts, while optional locking DIN rail clips ensure vibration-resistant installation in mobile equipment and offshore platforms. Cable management accessories route field wiring cleanly, maintaining separation between power and signal cables for optimal EMC performance.

Related DeltaV Carrier Products

Product Model Description Product Link
VE4050E1C0 DeltaV 8-Wide I/O Interface Carrier (Standard Version) View Product
VE4050S2K1C0 (Logic Solver) 8-Wide Logic Solver Horizontal Carrier for SIS Applications View Product
VE4050S2K1C0 Complete 8-Wide I/O Carrier with Terminal Block Assembly View Product

Quality Assurance & Lifecycle Support

Factory-tested to IEC 61131-2 industrial controller standards with full burn-in testing and environmental stress screening. Ships with installation guide, power budget calculator, and configuration templates for common I/O arrangements. Backed by 24-month warranty covering manufacturing defects and performance specifications.

Global technical support provides system design assistance, power budget validation, and troubleshooting guidance for complex distributed I/O architectures. Replacement carriers ship pre-tested and ready for installation, minimizing emergency repair downtime.

© 2025 INDUSTRIAL CONTROL HUB. All rights reserved.