Product Description
| Model Description | |
|---|---|
| Field | Details | 
| Model | VE4003S2B1 | 
| Description | Analog Input Card, 8 Channels, 4-20 mA, HART. Includes Standard I/O Termination Block. | 
| Technical Specifications | |
|---|---|
| Parameter | Specification | 
| Number of Channels | 8 | 
| Isolation | Each channel is optically isolated from the system and factory tested to 1500 V DC. | 
| Nominal Signal Range (Span) | 4 to 20 mA | 
| Full Signal Range | 1 to 22.5 mA, with over range checking | 
| LocalBus Current (12V DC nominal) | Simplex: 120 mA typical, 150 mA maximum<br>Redundant: 175 mA typical, 250 mA maximum (per card) | 
| Field Circuit Power | 300 mA maximum at 24V DC (±10%) | 
| Accuracy Over Temperature Range | 0.1% of span | 
| Resolution | 16-bit A/D converter | 
| Repeatability | 0.05% of span | 
| Roll-off Frequency | -3 dB at 2.7 Hz, -20.5 dB at 1/2 the sampling frequency | 
| Calibration | None required | 
| Optional Fuse | 2.0 A | 
| Communications Support | HART pass-through for AMS Device Manager. Field device variable and status reporting for control functions. | 
| HART Scan Time | 600-800 ms (typical) per enabled channel | 
| Compatibility | |
|---|---|
| Component | Specification | 
| I/O Card Keying | A1 | 
| Conventional I/O Terminal Block | Standard I/O Termination Block<br>Fused I/O Termination Block<br>4-wire I/O Termination Block | 
| Mass Termination Block | 16-pin Mass Termination Block (Supports 2-wire Devices)<br>24-pin Mass Termination Block (Supports 4-wire Devices) | 
| Certifications | |
|---|---|
| Certification Type | Details | 
| FM (USA) | Class I, Division 2, Groups A, B, C, D, T4 | 
| cFM (Canada) | Class I, Division 2, Groups A, B, C, D, T4 | 
| ATEX | II 3G Ex ec IIC T4 Gc<br>II 3G Ex nA nC IIC T4 Gc | 
| IEC-Ex | Ex ec IIC T4 Gc<br>Ex nA nC IIC T4 Gc | 
| Zone 2 Ex nA Certified | Yes | 
| Zone 2 Ex nL / Ex ic | No | 
| Class I Division II Non-Incendive | No | 
| Additional Information | |
|---|---|
| Field | Details | 
| System Compatibility | M-series Traditional I/O cards are not physically compatible with S-series controller carriers. Requires MQ, MX, or PK controllers and M-series horizontal or VerticalPlus carriers. Supported on DeltaV v10.3.1 and later. | 
| Ordering Information | VE4003S2B1 includes Standard I/O Termination Block. | 
| Installation Instructions | Refer to:<br>• Class 1 Division 2 Installation Instructions DeltaV M-Series 12P1293<br>• Zone 2 Installation Instructions DeltaV M-Series 12P2046 | 
| Reference Documents | |
|---|---|
| Document | Description | 
| PDS M-series Mass Connection Solution | For further details on the Mass Connection Boards | 
| Installation Standards | Ensure compliance with standards and certifications detailed in installation documentation. | 
 
           
     
     
     
     
     
    