Skip to product information
1 of 4

Emerson ‎‎VE4001S5T2B4 DeltaV M-series Discrete Input Module

Emerson ‎‎VE4001S5T2B4 DeltaV M-series Discrete Input Module

  • Manufacturer: Emerson

  • Product No.: VE4001S5T2B4

  • Condition:1000 in stock

  • Product Type: DeltaV M-series Discrete Input Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 400g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Overview

Parameter Details
Product Name Discrete 32-Channel Terminal Block for Sequence of Event Input Card
Model Number VE4001S5T2B4
Category DeltaV M-series Traditional I/O - Discrete Input Termination Blocks
Function Connects field wiring for 16-channel Sequence of Event (SOE) Input card (24V DC, Dry Contact) to the I/O interface carrier
System Compatibility DeltaV M-series Traditional I/O, used with 16-channel SOE Input card (I/O card keying C5) on M-series horizontal or VerticalPlus carriers

Hardware Specifications

Specification Value
Type Terminal Block, 32-channel (supports 16 channels for SOE card)
Associated I/O Card Sequence of Event Input Card: 16 Channels, 24V DC, Dry Contact (I/O card keying C5)
Number of Channels Supports 16 channels
Wiring Compatibility Connects field wiring for dry contact inputs (detection: >2 mA for On, <0.25 mA for Off)
Input Impedance 5 KΩ (approximate)
Wetting Voltage 24V DC
Field Circuit Power 75 mA at 24V DC per card
Isolation Each channel optically isolated from the system, tested to 1500V DC
LocalBus Current 75 mA typical, 100 mA maximum (12V DC nominal) per card
Keying I/O card keying C5, ensuring correct card installation
Time Stamp Accuracy 0.25 ms for same card, 1 ms for same controller
Channel Scan Rate 0.25 ms for all 16 channels

Environmental Specifications

Parameter Value
Operating Temperature -40 to 70°C (-40 to 158°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5 to 95%, non-condensing
Airborne Contaminants ISA-S71.04-1985 Class G3, conformal coating
Protection Rating IP 20
Shock 10 g ½-sine wave for 11 ms
Vibration 1 mm peak-to-peak from 5 to 16 Hz; 0.5 g from 16 to 150 Hz
Dimensions (I/O Interface) H 10.7 cm (4.2 in), W 4.1 cm (1.6 in), Depth 10.5 cm (4.1 in)

Certifications

Standard Details
CE EMC: EN 61326-1
FM FM 3600, FM 3611
CSA CSA C22.2 No. 213, CSA C22.2 No. 1010-1
ATEX EN60079-0, IEC60079-7, EN60079-15
IEC-Ex IEC60079-0, IEC60079-7, IEC60079-15
Marine IACS E10, ABS Certificate of Design Assessment, DNV Marine Certificate

Hazardous Area Approvals

Standard Details
FM (USA) Class I, Division 2, Groups A, B, C, D, T4
cFM (Canada) Class I, Division 2, Groups A, B, C, D, T4
ATEX II 3G Ex ec IIC T4 Gc, II 3G Ex nA nC IIC T4 Gc
IEC-Ex II 3G Ex ec IIC T4 Gc, II 3G Ex nA nC IIC T4 Gc

Physical & Installation

Parameter Details
Mounting Mounts on I/O interface carrier (DIN rail surface-mounted)
Installation Type 32-channel terminal block for wiring; plugs into I/O interface carrier
Wiring Supports 32-screw termination for field wiring, configured for 16 channels; compatible with mass termination solutions
Keying Mechanism Keying posts (C5) with 6 positions (A-F, 1-6) to prevent incorrect card installation
Installation Notes Suitable for hazardous areas (Class I, Division 2, Zone 2); follow installation instructions

Functional Features

Feature
Facilitates wiring for 16-channel SOE Input card (24V DC, Dry Contact) for high-precision event logging
Supports dry contact inputs with detection levels: >2 mA (On), <0.25 mA (Off)
Optically isolated channels (1500V DC) for enhanced safety and reliability
Provides high-resolution time stamping: 0.25 ms per card, 1 ms per controller
Compatible with M-series horizontal or VerticalPlus carriers
Plug-and-play installation on I/O interface carrier, reducing installation time
Keying mechanism (C5) ensures correct I/O card installation
Supports online equipment additions without process interruption
Suitable for hazardous areas with ATEX/IEC-Ex and FM/CSA certifications
Designed for sequence-of-event data collection in critical process automation applications

Ordering Information

Description Model Number
Sequence of Event Input Card: 16 Channels, 24V DC, Dry Contact - Discrete 32-Channel Terminal Block VE4001S5T2B4

View full details

Product Description

Product Overview

Parameter Details
Product Name Discrete 32-Channel Terminal Block for Sequence of Event Input Card
Model Number VE4001S5T2B4
Category DeltaV M-series Traditional I/O - Discrete Input Termination Blocks
Function Connects field wiring for 16-channel Sequence of Event (SOE) Input card (24V DC, Dry Contact) to the I/O interface carrier
System Compatibility DeltaV M-series Traditional I/O, used with 16-channel SOE Input card (I/O card keying C5) on M-series horizontal or VerticalPlus carriers

Hardware Specifications

Specification Value
Type Terminal Block, 32-channel (supports 16 channels for SOE card)
Associated I/O Card Sequence of Event Input Card: 16 Channels, 24V DC, Dry Contact (I/O card keying C5)
Number of Channels Supports 16 channels
Wiring Compatibility Connects field wiring for dry contact inputs (detection: >2 mA for On, <0.25 mA for Off)
Input Impedance 5 KΩ (approximate)
Wetting Voltage 24V DC
Field Circuit Power 75 mA at 24V DC per card
Isolation Each channel optically isolated from the system, tested to 1500V DC
LocalBus Current 75 mA typical, 100 mA maximum (12V DC nominal) per card
Keying I/O card keying C5, ensuring correct card installation
Time Stamp Accuracy 0.25 ms for same card, 1 ms for same controller
Channel Scan Rate 0.25 ms for all 16 channels

Environmental Specifications

Parameter Value
Operating Temperature -40 to 70°C (-40 to 158°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5 to 95%, non-condensing
Airborne Contaminants ISA-S71.04-1985 Class G3, conformal coating
Protection Rating IP 20
Shock 10 g ½-sine wave for 11 ms
Vibration 1 mm peak-to-peak from 5 to 16 Hz; 0.5 g from 16 to 150 Hz
Dimensions (I/O Interface) H 10.7 cm (4.2 in), W 4.1 cm (1.6 in), Depth 10.5 cm (4.1 in)

Certifications

Standard Details
CE EMC: EN 61326-1
FM FM 3600, FM 3611
CSA CSA C22.2 No. 213, CSA C22.2 No. 1010-1
ATEX EN60079-0, IEC60079-7, EN60079-15
IEC-Ex IEC60079-0, IEC60079-7, IEC60079-15
Marine IACS E10, ABS Certificate of Design Assessment, DNV Marine Certificate

Hazardous Area Approvals

Standard Details
FM (USA) Class I, Division 2, Groups A, B, C, D, T4
cFM (Canada) Class I, Division 2, Groups A, B, C, D, T4
ATEX II 3G Ex ec IIC T4 Gc, II 3G Ex nA nC IIC T4 Gc
IEC-Ex II 3G Ex ec IIC T4 Gc, II 3G Ex nA nC IIC T4 Gc

Physical & Installation

Parameter Details
Mounting Mounts on I/O interface carrier (DIN rail surface-mounted)
Installation Type 32-channel terminal block for wiring; plugs into I/O interface carrier
Wiring Supports 32-screw termination for field wiring, configured for 16 channels; compatible with mass termination solutions
Keying Mechanism Keying posts (C5) with 6 positions (A-F, 1-6) to prevent incorrect card installation
Installation Notes Suitable for hazardous areas (Class I, Division 2, Zone 2); follow installation instructions

Functional Features

Feature
Facilitates wiring for 16-channel SOE Input card (24V DC, Dry Contact) for high-precision event logging
Supports dry contact inputs with detection levels: >2 mA (On), <0.25 mA (Off)
Optically isolated channels (1500V DC) for enhanced safety and reliability
Provides high-resolution time stamping: 0.25 ms per card, 1 ms per controller
Compatible with M-series horizontal or VerticalPlus carriers
Plug-and-play installation on I/O interface carrier, reducing installation time
Keying mechanism (C5) ensures correct I/O card installation
Supports online equipment additions without process interruption
Suitable for hazardous areas with ATEX/IEC-Ex and FM/CSA certifications
Designed for sequence-of-event data collection in critical process automation applications

Ordering Information

Description Model Number
Sequence of Event Input Card: 16 Channels, 24V DC, Dry Contact - Discrete 32-Channel Terminal Block VE4001S5T2B4

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)