Skip to product information
1 of 7

Emerson ‎‎VE3007 KJ2005X1-BA2 DeltaV MX Controller

Emerson ‎‎VE3007 KJ2005X1-BA2 DeltaV MX Controller

  • Manufacturer: Emerson

  • Product No.: KJ2005X1-BA2

  • Condition:1000 in stock

  • Product Type: DeltaV MX Controller

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 300g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Overview

Parameter Details
Product Name DeltaV MX Controller
Model Number VE3007
Part Number KJ2005X1-BA2
Category DeltaV Controller
Function Provides communication and control between field devices and control network
System Compatibility DeltaV v10.3 or later; supports PROVOX and RS3 migration

Hardware & Electrical Specifications

Specification Value
Power Requirement Supplied by System Power Supply through 2-wide Power/Controller Carrier
Fuse Protection 3.0 A, non-replaceable fuses
Power Dissipation 5.0 W typical, 7.0 W maximum
User Memory 96 MB
Primary Control Network 8-pin RJ-45 connector, 100 MB/s full duplex Ethernet
Redundant Control Network 8-pin RJ-45 connector, 100 MB/s full duplex Ethernet

LED Indicators

Indicator Description
Green - Power Indicates DC power is applied
Red - Error Indicates an error condition
Green - Active Indicates controller is operating as the primary controller
Green - Standby Indicates controller is operating as a backup controller (future use)
Yellow Flashing - Pri. CN Indicates valid primary control network communication
Yellow Flashing - Sec. CN Indicates valid secondary control network communication
All except Power Flashing Visual identification initiated by ping command
All except Power Flashing (Even/Odd) Firmware upgrade in progress

Environmental Specifications

Parameter Value
Operating Temperature -40 to 70°C (-40 to 158°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5 to 95%, non-condensing
Airborne Contaminants ISA-S71.04-1985 Class G3, Conformal coating
Shock 10 g ½-sine wave for 11 ms
Vibration 1 mm peak-to-peak from 5 to 16 Hz; 0.5 g from 16 to 150 Hz

Certifications

Standard Details
ATEX EEx nA IIC T4
FM (USA) Class I, Div 2, Groups A, B, C, D, T4

Physical & Installation

Parameter Details
Mounting On right slot of 2-wide Power/Controller Carrier
Installation Type Plug-and-play, modular system growth
Removal/Insertion Refer to Zone 2 (12P2046) or Class I Div 2 (12P1293) installation instructions
Maintenance No user-serviceable parts; calibration not required

Functional Features

Feature
Twice the control capacity, user-configurable memory, and DST count of MD Plus Controller
High performance for demanding control applications, including oil and gas, chemical processing, and power generation
Scalable for small to large control systems
Reliable operation in harsh industrial environments
Easy-to-use with quick configuration
Supports single-loop control for process variables
Universal input/output for analog and digital signals
Seamless communication interface with DeltaV systems
Self-addressing and self-locating with no dip switches
Automatic I/O detection for plugged-in I/O interfaces
Manages all control activities, communication, time stamping, alarming, and trends
Data protection with automatic saving of installation and online changes
Cold restart without manual intervention or network devices
Supports DeltaV Batch, Neural, and Model Predictive Control
HART data pass-through for remote device management
Scalable from 50 to 1500 Device Signal Tags (DSTs)
Supports 1:1 redundancy for increased reliability
Migration support for PROVOX and RS3 with up to 750 real I/O signals

Ordering Information

Description Model Number Part Number
DeltaV MX Controller VE3007 KJ2005X1-BA2

View full details

Product Description

Product Overview

Parameter Details
Product Name DeltaV MX Controller
Model Number VE3007
Part Number KJ2005X1-BA2
Category DeltaV Controller
Function Provides communication and control between field devices and control network
System Compatibility DeltaV v10.3 or later; supports PROVOX and RS3 migration

Hardware & Electrical Specifications

Specification Value
Power Requirement Supplied by System Power Supply through 2-wide Power/Controller Carrier
Fuse Protection 3.0 A, non-replaceable fuses
Power Dissipation 5.0 W typical, 7.0 W maximum
User Memory 96 MB
Primary Control Network 8-pin RJ-45 connector, 100 MB/s full duplex Ethernet
Redundant Control Network 8-pin RJ-45 connector, 100 MB/s full duplex Ethernet

LED Indicators

Indicator Description
Green - Power Indicates DC power is applied
Red - Error Indicates an error condition
Green - Active Indicates controller is operating as the primary controller
Green - Standby Indicates controller is operating as a backup controller (future use)
Yellow Flashing - Pri. CN Indicates valid primary control network communication
Yellow Flashing - Sec. CN Indicates valid secondary control network communication
All except Power Flashing Visual identification initiated by ping command
All except Power Flashing (Even/Odd) Firmware upgrade in progress

Environmental Specifications

Parameter Value
Operating Temperature -40 to 70°C (-40 to 158°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5 to 95%, non-condensing
Airborne Contaminants ISA-S71.04-1985 Class G3, Conformal coating
Shock 10 g ½-sine wave for 11 ms
Vibration 1 mm peak-to-peak from 5 to 16 Hz; 0.5 g from 16 to 150 Hz

Certifications

Standard Details
ATEX EEx nA IIC T4
FM (USA) Class I, Div 2, Groups A, B, C, D, T4

Physical & Installation

Parameter Details
Mounting On right slot of 2-wide Power/Controller Carrier
Installation Type Plug-and-play, modular system growth
Removal/Insertion Refer to Zone 2 (12P2046) or Class I Div 2 (12P1293) installation instructions
Maintenance No user-serviceable parts; calibration not required

Functional Features

Feature
Twice the control capacity, user-configurable memory, and DST count of MD Plus Controller
High performance for demanding control applications, including oil and gas, chemical processing, and power generation
Scalable for small to large control systems
Reliable operation in harsh industrial environments
Easy-to-use with quick configuration
Supports single-loop control for process variables
Universal input/output for analog and digital signals
Seamless communication interface with DeltaV systems
Self-addressing and self-locating with no dip switches
Automatic I/O detection for plugged-in I/O interfaces
Manages all control activities, communication, time stamping, alarming, and trends
Data protection with automatic saving of installation and online changes
Cold restart without manual intervention or network devices
Supports DeltaV Batch, Neural, and Model Predictive Control
HART data pass-through for remote device management
Scalable from 50 to 1500 Device Signal Tags (DSTs)
Supports 1:1 redundancy for increased reliability
Migration support for PROVOX and RS3 with up to 750 real I/O signals

Ordering Information

Description Model Number Part Number
DeltaV MX Controller VE3007 KJ2005X1-BA2

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)