Skip to product information
1 of 7

Emerson SS3001 KL4103X1-BA1 Intrinsically Safe (IS) CHARMs

Emerson SS3001 KL4103X1-BA1 Intrinsically Safe (IS) CHARMs

  • Manufacturer: Emerson

  • Product No.: KL4103X1-BA1

  • Condition:1000 in stock

  • Product Type: Intrinsically Safe (IS) CHARMs

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Overview

Parameter Details
Product Name CSLS CHARM
Model Number SS3001
Category Intrinsically Safe (IS) CHARMs
Function Provides logic solver functionality for safety instrumented systems (SIS)
System Compatibility DeltaV SIS with Electronic Marshalling (v11.3.1 or later)
Terminal Block IS Terminal Block (Light Blue, 4 terminals)

Hardware & Electrical Specifications

Specification Value
Functionality Executes safety logic for SIS, interfacing with field devices
CHARM Power Requirement 30 mA max @ 24 V DC ± 10% (inferred from typical IS CHARM power range)
CHARM Heat Dissipation 0.5 W (inferred from typical IS CHARM heat dissipation)
Isolation Galvanically isolated per EN 60079-11; voltage peak value 375 V DC

Environmental Specifications

Parameter Value
Operating Temperature -40 to 70°C (or -40 to 60°C for fanless enclosures)
Storage Temperature -40 to 85°C
Relative Humidity 5 to 95%, non-condensing
Protection Rating IP20
Airborne Contaminants ISA-S71.04-1985 Class G3, Conformal coating
Shock 10 g ½-sine wave for 11 ms
Vibration 1 mm peak-to-peak from 2 to 13.2 Hz; 0.7 g from 13.2 to 150 Hz

Functional Features

Feature
Executes safety logic for DeltaV SIS applications
Supports integration with IS CHARM Baseplate for hazardous area use
LED Indicators:
- Power/Integrity (Bi-color): Green Solid (Normal), Green Blink (Awaiting configuration), Red Blink (Wiring fault), Red Solid (Internal fault)
Galvanic isolation per channel for intrinsically safe applications
Acts as a circuit protection device and field wiring disconnect
Surge protection to meet EMC industry standards
Can be partially ejected to a locked position for field maintenance

Certifications

Standard Details
CE EMC - EN 61326-1
FM (USA) Class I, Div 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx ec [ia Ga] IIC T4 Gc; Field Circuits: Class I, II, III, Div 1, Group A-G, T4
CSA (Canada) Class I, Div 2, Groups A, B, C, D, T4; Class I, Zone 2, Ex ec [ia Ga] IIC T4 Gc; Field Circuits: Class I, II, III, Div 1, Group A-G, T4
ATEX II 3(1) G Ex ec [ia Ga] IIC T4 Gc; II 3 G (1D) Ex ec [ia IIIC Da] IIC Gc
IEC-Ex II 3(1) G Ex ec [ia Ga] IIC T4 Gc; II 3 G (1D) Ex ec [ia IIIC Da] IIC Gc
Marine DNV Marine Certificate; IACS E10
Achilles CIOC: Level 1 (v13.3.1); CIOC2: Level 2 (v14.3)

Physical & Installation

Parameter Details
Installation Type Mounted on IS CHARM Baseplate (DIN rail)
Wiring 4 screw cage terminals, 0.32–2.5 mm² (22–14 AWG), 7–9 mm strip length (IS Terminal Block)
Maximum Current 45 mA at 28 V DC max
Terminal Block Color Light Blue (Intrinsically Safe)
Keying Keying posts automatically set on first CHARM insertion; can be manually reset to change CHARM type
Removal/Insertion Can be partially ejected to a locked position for field maintenance; full removal requires non-hazardous area or de-energized system
Maintenance No user-serviceable parts; calibration not required

Hazardous Area Installation

Parameter Details
Installation Instructions Refer to ATEX/IECEx installation instructions (12P6523); Control Drawings (12P6123)
Hazardous Area Standards Suitable for Class I, Div 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx/Ex ec [ia Ga] IIC T4 Gc; ATEX II 3(1) G Ex ec [ia Ga] IIC T4 Gc

Ordering Information

Description Model Number
CSLS CHARM SS3001
IS CHARMs Baseplate Assembly with Standard IS CHARM Terminal Blocks SE4608T01
IS CHARM Protection Cover (Package of 12) SE6104

View full details

Product Description

Product Overview

Parameter Details
Product Name CSLS CHARM
Model Number SS3001
Category Intrinsically Safe (IS) CHARMs
Function Provides logic solver functionality for safety instrumented systems (SIS)
System Compatibility DeltaV SIS with Electronic Marshalling (v11.3.1 or later)
Terminal Block IS Terminal Block (Light Blue, 4 terminals)

Hardware & Electrical Specifications

Specification Value
Functionality Executes safety logic for SIS, interfacing with field devices
CHARM Power Requirement 30 mA max @ 24 V DC ± 10% (inferred from typical IS CHARM power range)
CHARM Heat Dissipation 0.5 W (inferred from typical IS CHARM heat dissipation)
Isolation Galvanically isolated per EN 60079-11; voltage peak value 375 V DC

Environmental Specifications

Parameter Value
Operating Temperature -40 to 70°C (or -40 to 60°C for fanless enclosures)
Storage Temperature -40 to 85°C
Relative Humidity 5 to 95%, non-condensing
Protection Rating IP20
Airborne Contaminants ISA-S71.04-1985 Class G3, Conformal coating
Shock 10 g ½-sine wave for 11 ms
Vibration 1 mm peak-to-peak from 2 to 13.2 Hz; 0.7 g from 13.2 to 150 Hz

Functional Features

Feature
Executes safety logic for DeltaV SIS applications
Supports integration with IS CHARM Baseplate for hazardous area use
LED Indicators:
- Power/Integrity (Bi-color): Green Solid (Normal), Green Blink (Awaiting configuration), Red Blink (Wiring fault), Red Solid (Internal fault)
Galvanic isolation per channel for intrinsically safe applications
Acts as a circuit protection device and field wiring disconnect
Surge protection to meet EMC industry standards
Can be partially ejected to a locked position for field maintenance

Certifications

Standard Details
CE EMC - EN 61326-1
FM (USA) Class I, Div 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx ec [ia Ga] IIC T4 Gc; Field Circuits: Class I, II, III, Div 1, Group A-G, T4
CSA (Canada) Class I, Div 2, Groups A, B, C, D, T4; Class I, Zone 2, Ex ec [ia Ga] IIC T4 Gc; Field Circuits: Class I, II, III, Div 1, Group A-G, T4
ATEX II 3(1) G Ex ec [ia Ga] IIC T4 Gc; II 3 G (1D) Ex ec [ia IIIC Da] IIC Gc
IEC-Ex II 3(1) G Ex ec [ia Ga] IIC T4 Gc; II 3 G (1D) Ex ec [ia IIIC Da] IIC Gc
Marine DNV Marine Certificate; IACS E10
Achilles CIOC: Level 1 (v13.3.1); CIOC2: Level 2 (v14.3)

Physical & Installation

Parameter Details
Installation Type Mounted on IS CHARM Baseplate (DIN rail)
Wiring 4 screw cage terminals, 0.32–2.5 mm² (22–14 AWG), 7–9 mm strip length (IS Terminal Block)
Maximum Current 45 mA at 28 V DC max
Terminal Block Color Light Blue (Intrinsically Safe)
Keying Keying posts automatically set on first CHARM insertion; can be manually reset to change CHARM type
Removal/Insertion Can be partially ejected to a locked position for field maintenance; full removal requires non-hazardous area or de-energized system
Maintenance No user-serviceable parts; calibration not required

Hazardous Area Installation

Parameter Details
Installation Instructions Refer to ATEX/IECEx installation instructions (12P6523); Control Drawings (12P6123)
Hazardous Area Standards Suitable for Class I, Div 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx/Ex ec [ia Ga] IIC T4 Gc; ATEX II 3(1) G Ex ec [ia Ga] IIC T4 Gc

Ordering Information

Description Model Number
CSLS CHARM SS3001
IS CHARMs Baseplate Assembly with Standard IS CHARM Terminal Blocks SE4608T01
IS CHARM Protection Cover (Package of 12) SE6104

Download PDF file here:

Click to Download PDF

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)