Skip to product information
1 of 6

Emerson SE4502 IS Thermocouple/mV CHARM

Emerson SE4502 IS Thermocouple/mV CHARM

  • Manufacturer: Emerson

  • Product No.: SE4502

  • Condition:1000 in stock

  • Product Type: IS Thermocouple/mV CHARM

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 50g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Overview

Parameter Details
Product Name IS Thermocouple/mV CHARM
Model Number SE4502
Category Intrinsically Safe (IS) CHARMs
Function Analog Input for Thermocouple and mV signals
System Compatibility DeltaV v11.3.1 or later (with SD Plus, SX, SQ, MQ, MX, PK Controllers)
Terminal Block IS Terminal Block (Light Blue, 4 terminals)

Hardware & Electrical Specifications

Specification Value
Sensor Types Thermocouple (Types B, E, J, K, N, R, S, T); mV (±100 mV)
Full Signal Range -100 to +100 mV
Accuracy Varies by sensor type (see table below); ±0.25°C for CJC
Resolution 16-bit A/D converter
Calibration None required
Cold Junction Compensation (CJC) Local CJC provided by IS Terminal Block; accuracy ±0.25°C
Isolation Galvanically isolated per EN 60079-11; voltage peak value 375 V DC
CHARM Power Requirement 22 mA max @ 24 V DC ± 10%
CHARM Heat Dissipation 0.33 W

Accuracy for Sensor Types

Sensor Type Accuracy @ 25°C Accuracy Over Temperature Range (-40 to 70°C)
Type B ±2.75°C ±6.75°C
Type E ±0.5°C ±1.5°C
Type J ±0.65°C ±2.0°C
Type K ±0.75°C ±2.25°C
Type N ±0.85°C ±2.5°C
Type R ±2.5°C ±6.25°C
Type S ±2.5°C ±6.25°C
Type T ±0.65°C ±2.0°C
mV ±0.025 mV ±0.075 mV

Environmental Specifications

Parameter Value
Operating Temperature -40 to 70°C (or -40 to 60°C for fanless enclosures)
Storage Temperature -40 to 85°C
Relative Humidity 5 to 95%, non-condensing
Protection Rating IP20
Airborne Contaminants ISA-S71.04-1985 Class G3, Conformal coating
Shock 10 g ½-sine wave for 11 ms
Vibration 1 mm peak-to-peak from 2 to 13.2 Hz; 0.7 g from 13.2 to 150 Hz

Functional Features

Feature
Supports multiple thermocouple types (B, E, J, K, N, R, S, T) and mV signals
Local Cold Junction Compensation (CJC) integrated into IS Terminal Block
LED Indicators:
- Power/Integrity (Bi-color): Green Solid (Normal), Green Blink (Awaiting configuration), Red Blink (Wiring fault), Red Solid (Internal fault)
Galvanic isolation per channel for intrinsically safe applications
Acts as a circuit protection device and field wiring disconnect
Surge protection to meet EMC industry standards
Can be partially ejected to a locked position for field maintenance

Certifications

Standard Details
CE EMC - EN 61326-1
FM (USA) Class I, Div 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx ec [ia Ga] IIC T4 Gc; Field Circuits: Class I, II, III, Div 1, Group A-G, T4
CSA (Canada) Class I, Div 2, Groups A, B, C, D, T4; Class I, Zone 2, Ex ec [ia Ga] IIC T4 Gc; Field Circuits: Class I, II, III, Div 1, Group A-G, T4
ATEX II 3(1) G Ex ec [ia Ga] IIC T4 Gc; II 3 G (1D) Ex ec [ia IIIC Da] IIC Gc
IEC-Ex II 3(1) G Ex ec [ia Ga] IIC T4 Gc; II 3 G (1D) Ex ec [ia IIIC Da] IIC Gc
Marine DNV Marine Certificate; IACS E10
Achilles CIOC: Level 1 (v13.3.1); CIOC2: Level 2 (v14.3)

Physical & Installation

Parameter Details
Installation Type Mounted on IS CHARM Baseplate (DIN rail)
Wiring 4 screw cage terminals, 0.32–2.5 mm² (22–14 AWG), 7–9 mm strip length (IS Terminal Block)
Maximum Current 45 mA at 28 V DC max
Terminal Block Color Light Blue (Intrinsically Safe)
Keying Keying posts automatically set on first CHARM insertion; can be manually reset to change CHARM type
Removal/Insertion Can be partially ejected to a locked position for field maintenance; full removal requires non-hazardous area or de-energized system
Maintenance No user-serviceable parts; calibration not required

Hazardous Area Installation

Parameter Details
Installation Instructions Refer to ATEX/IECEx installation instructions (12P6523); Control Drawings (12P6123)
Hazardous Area Standards Suitable for Class I, Div 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx/Ex ec [ia Ga] IIC T4 Gc; ATEX II 3(1) G Ex ec [ia Ga] IIC T4 Gc

Ordering Information

Description Model Number
IS Thermocouple/mV CHARM SE4502
IS CHARMs Baseplate Assembly with Standard IS CHARM Terminal Blocks SE4608T01
IS CHARM Protection Cover (Package of 12) SE6104

View full details

Product Description

Product Overview

Parameter Details
Product Name IS Thermocouple/mV CHARM
Model Number SE4502
Category Intrinsically Safe (IS) CHARMs
Function Analog Input for Thermocouple and mV signals
System Compatibility DeltaV v11.3.1 or later (with SD Plus, SX, SQ, MQ, MX, PK Controllers)
Terminal Block IS Terminal Block (Light Blue, 4 terminals)

Hardware & Electrical Specifications

Specification Value
Sensor Types Thermocouple (Types B, E, J, K, N, R, S, T); mV (±100 mV)
Full Signal Range -100 to +100 mV
Accuracy Varies by sensor type (see table below); ±0.25°C for CJC
Resolution 16-bit A/D converter
Calibration None required
Cold Junction Compensation (CJC) Local CJC provided by IS Terminal Block; accuracy ±0.25°C
Isolation Galvanically isolated per EN 60079-11; voltage peak value 375 V DC
CHARM Power Requirement 22 mA max @ 24 V DC ± 10%
CHARM Heat Dissipation 0.33 W

Accuracy for Sensor Types

Sensor Type Accuracy @ 25°C Accuracy Over Temperature Range (-40 to 70°C)
Type B ±2.75°C ±6.75°C
Type E ±0.5°C ±1.5°C
Type J ±0.65°C ±2.0°C
Type K ±0.75°C ±2.25°C
Type N ±0.85°C ±2.5°C
Type R ±2.5°C ±6.25°C
Type S ±2.5°C ±6.25°C
Type T ±0.65°C ±2.0°C
mV ±0.025 mV ±0.075 mV

Environmental Specifications

Parameter Value
Operating Temperature -40 to 70°C (or -40 to 60°C for fanless enclosures)
Storage Temperature -40 to 85°C
Relative Humidity 5 to 95%, non-condensing
Protection Rating IP20
Airborne Contaminants ISA-S71.04-1985 Class G3, Conformal coating
Shock 10 g ½-sine wave for 11 ms
Vibration 1 mm peak-to-peak from 2 to 13.2 Hz; 0.7 g from 13.2 to 150 Hz

Functional Features

Feature
Supports multiple thermocouple types (B, E, J, K, N, R, S, T) and mV signals
Local Cold Junction Compensation (CJC) integrated into IS Terminal Block
LED Indicators:
- Power/Integrity (Bi-color): Green Solid (Normal), Green Blink (Awaiting configuration), Red Blink (Wiring fault), Red Solid (Internal fault)
Galvanic isolation per channel for intrinsically safe applications
Acts as a circuit protection device and field wiring disconnect
Surge protection to meet EMC industry standards
Can be partially ejected to a locked position for field maintenance

Certifications

Standard Details
CE EMC - EN 61326-1
FM (USA) Class I, Div 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx ec [ia Ga] IIC T4 Gc; Field Circuits: Class I, II, III, Div 1, Group A-G, T4
CSA (Canada) Class I, Div 2, Groups A, B, C, D, T4; Class I, Zone 2, Ex ec [ia Ga] IIC T4 Gc; Field Circuits: Class I, II, III, Div 1, Group A-G, T4
ATEX II 3(1) G Ex ec [ia Ga] IIC T4 Gc; II 3 G (1D) Ex ec [ia IIIC Da] IIC Gc
IEC-Ex II 3(1) G Ex ec [ia Ga] IIC T4 Gc; II 3 G (1D) Ex ec [ia IIIC Da] IIC Gc
Marine DNV Marine Certificate; IACS E10
Achilles CIOC: Level 1 (v13.3.1); CIOC2: Level 2 (v14.3)

Physical & Installation

Parameter Details
Installation Type Mounted on IS CHARM Baseplate (DIN rail)
Wiring 4 screw cage terminals, 0.32–2.5 mm² (22–14 AWG), 7–9 mm strip length (IS Terminal Block)
Maximum Current 45 mA at 28 V DC max
Terminal Block Color Light Blue (Intrinsically Safe)
Keying Keying posts automatically set on first CHARM insertion; can be manually reset to change CHARM type
Removal/Insertion Can be partially ejected to a locked position for field maintenance; full removal requires non-hazardous area or de-energized system
Maintenance No user-serviceable parts; calibration not required

Hazardous Area Installation

Parameter Details
Installation Instructions Refer to ATEX/IECEx installation instructions (12P6523); Control Drawings (12P6123)
Hazardous Area Standards Suitable for Class I, Div 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx/Ex ec [ia Ga] IIC T4 Gc; ATEX II 3(1) G Ex ec [ia Ga] IIC T4 Gc

Ordering Information

Description Model Number
IS Thermocouple/mV CHARM SE4502
IS CHARMs Baseplate Assembly with Standard IS CHARM Terminal Blocks SE4608T01
IS CHARM Protection Cover (Package of 12) SE6104

Download PDF file here:

Click to Download PDF

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)