Skip to product information
1 of 6

Emerson ‎‎SE4006P2 KJ3241X1-BK1+KJ4006X1-BD1 Interface Card

Emerson ‎‎SE4006P2 KJ3241X1-BK1+KJ4006X1-BD1 Interface Card

  • Manufacturer: Emerson

  • Product No.: KJ3241X1-BK1+KJ4006X1-BD1

  • Condition:1000 in stock

  • Product Type: S-series Serial Interface Card, 2-ports with Interface Terminal Block

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

📘 Product Overview

Field Details
Manufacturer Emerson
Model Numbers SE4006P2 (includes KJ3241X1-BK1 and simplex terminal block), KJ3241X1-BK1 (Serial Interface Card), KJ4006X1-BD1 (Interface Terminal Block)
Product Type S-series Serial Interface Card, 2-ports with Interface Terminal Block
Function Connects DeltaV system to devices with serial protocols (e.g., Modbus, Allen-Bradley Data Highway Plus)
System Compatibility DeltaV S-series controllers (SX, SQ), DeltaV v11.3 and higher
Included Components SE4006P2: 1 Serial Interface Card (KJ3241X1-BK1), 1 Simplex Terminal Block; KJ4006X1-BD1: Interface Terminal Block

⚙️ Hardware Specifications

Feature Specification
Number of Serial Ports 2 (on KJ3241X1-BK1)
Port Types RS232, RS422/485 half duplex, RS422/485 full duplex (individually configurable)
Number of Data Sets 32 (16 per port)
Isolation Each port isolated from the system and from each other, externally grounded
LocalBus Power 12 V DC at 300 mA (KJ3241X1-BK1)
Field Power (Terminal Block) 35 V DC at 1 A (KJ4006X1-BD1)
Mounting Plugs into any slot on 8-wide I/O carrier
Terminal Block Keying Set according to I/O card installed (KJ4006X1-BD1); rotary keying system ensures compatibility

🔌 Communication Specifications

Feature Specification
Supported Protocols Modbus RTU, Modbus ASCII (pre-installed); custom drivers: Allen-Bradley Data Highway Plus, Mettler Weight Scale, Redundant Enhanced Modbus, Sartorius Weight Scale
Baud Rate 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Parity Even, Odd, None
Data Bits 7 or 8
Stop Bits 1 or 2
Retry Count 0–255
Message Timeout 100–25,500 ms (100 ms increments)
Transmit Delay 0–25,500 ms (100 ms increments)
Send Outputs on Startup Configurable in DeltaV Explorer to send outputs on interface initialization
Modbus Functions - Read: Coils, Input Status, Holding Registers, Input Registers
- Write: Single Coil, Holding Registers (single, register, or dataset mode)
- Input data read as complete dataset for best performance

🔁 Redundancy Features

Feature Details
Redundancy Option Available as redundant pair (model SE4036P2, not SE4006P2) with redundant terminal block
Redundancy Setup Autosensed by DeltaV system; requires slave device with two serial ports
Switchover Triggers Hardware failure, loss of communication (field cable/slave port issues), card removal, control logic, manual switch via Diagnostics Explorer
Switchover Time Minimal, process undisturbed; configurable to resend outputs on switchover
Standby Operation Standby card polls slave device for diagnostic register to confirm readiness
Notification Operator notified of switchover via integrity error alarm on primary card
Replacement Auto-commissioned standby card; replaceable under power in safe areas, follow hazardous area procedures

🌡️ Environmental Specifications

Parameter Specification
Operating Temperature -40 to 70 °C (-40 to 158 °F)
Storage Temperature -40 to 85 °C (-40 to 185 °F)
Relative Humidity 5 to 95%, non-condensing
Airborne Contaminants ISA-S71.04-1985 Class G3
Protection Rating IP20 (KJ3241X1-BK1)
Shock 10 g ½-sine wave for 11 ms
Vibration KJ3241X1-BK1: 1 mm peak-to-peak (5–16 Hz), 0.5 g (16–150 Hz)
KJ4006X1-BD1: 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz)

✅ Certifications

Standard Details
CE EMC - EN 61326-1
FM (USA) FM 3600, FM 3611; Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx/Ex ec IIC Gc (KJ4006X1-BD1)
cFM (Canada) CSA C22.2 No. 213, CSA C22.2 No. 1010.1; Class I, Division 2, Groups A, B, C, D, T4; FM17CA0145U (KJ4006X1-BD1)
ATEX II 3G Ex nA IIC T4 Gc (KJ3241X1-BK1, Nemko No. 11ATEX3029U); II 3G Ex ec IIC Gc (KJ4006X1-BD1, FM19ATEX0173U)
IEC-Ex II 3G Ex ec IIC Gc (KJ4006X1-BD1, IECEx FMG 19.0019U)
UKEX FM21UKEX0017U (KJ4006X1-BD1)
Marine IACS E10, ABS Certificate of Design Assessment, DNV Type Approval Certificate
Installation Instructions Class I Division 2: 12P1293 (KJ3241X1-BK1), 12P5402 (KJ4006X1-BD1)
Zone 2: 12P2046 (KJ3241X1-BK1), 12P5404 (KJ4006X1-BD1)

🛠️ Installation and Configuration

Feature Details
Installation Plugs into 8-wide I/O carrier; no dipswitches; terminal block removable only without I/O card or field wiring (KJ4006X1-BD1)
Removal/Insertion KJ3241X1-BK1: Cannot be removed/inserted with system power energized
KJ4006X1-BD1: Terminal block can be added/removed with system power if no I/O card or field wiring is connected
Configuration Auto-sensed by DeltaV controller; configured via DeltaV Explorer with point-and-click interface
Data Handling - Direct module-to-dataset/register references for control signals
- Marshalling module for multiple registers at 1 DST cost
- SCADA values to workstations/historians without DST consumption
Maintenance No user-serviceable parts; no calibration required

📦 Ordering Information

Description Model Number
S-series Serial Interface Card, 2-ports (Simplex) SE4006P2 (includes KJ3241X1-BK1 and simplex terminal block)
Redundant S-series Serial Interface Card, 2-ports SE4036P2 (includes 2 interface cards and redundant terminal block)
Interface Terminal Block KJ4006X1-BD1

📝 Additional Notes

  • Modbus Support: Pre-installed Modbus RTU and ASCII drivers; supports master or slave configuration per port.
  • Custom Drivers: Available from Emerson (e.g., Allen-Bradley Data Highway Plus, Mettler/Sartorius Weight Scales); contact local sales office for availability.
  • Redundancy Limitation: SE4006P2 is simplex; for redundancy, use SE4036P2. Slave devices must support dual serial ports for redundant operation.
  • DST Usage: Datasets can be referenced directly in control modules or marshalled for cost-effective integration; SCADA tags do not consume DSTs.
  • Hazardous Area Operation: Follow specific installation instructions for Class I Division 2 (12P1293, 12P5402) and Zone 2 (12P2046, 12P5404).
  • Terminal Block Compatibility: KJ4006X1-BD1 key position must match KJ3241X1-BK1 for proper installation.
View full details

Product Description

📘 Product Overview

Field Details
Manufacturer Emerson
Model Numbers SE4006P2 (includes KJ3241X1-BK1 and simplex terminal block), KJ3241X1-BK1 (Serial Interface Card), KJ4006X1-BD1 (Interface Terminal Block)
Product Type S-series Serial Interface Card, 2-ports with Interface Terminal Block
Function Connects DeltaV system to devices with serial protocols (e.g., Modbus, Allen-Bradley Data Highway Plus)
System Compatibility DeltaV S-series controllers (SX, SQ), DeltaV v11.3 and higher
Included Components SE4006P2: 1 Serial Interface Card (KJ3241X1-BK1), 1 Simplex Terminal Block; KJ4006X1-BD1: Interface Terminal Block

⚙️ Hardware Specifications

Feature Specification
Number of Serial Ports 2 (on KJ3241X1-BK1)
Port Types RS232, RS422/485 half duplex, RS422/485 full duplex (individually configurable)
Number of Data Sets 32 (16 per port)
Isolation Each port isolated from the system and from each other, externally grounded
LocalBus Power 12 V DC at 300 mA (KJ3241X1-BK1)
Field Power (Terminal Block) 35 V DC at 1 A (KJ4006X1-BD1)
Mounting Plugs into any slot on 8-wide I/O carrier
Terminal Block Keying Set according to I/O card installed (KJ4006X1-BD1); rotary keying system ensures compatibility

🔌 Communication Specifications

Feature Specification
Supported Protocols Modbus RTU, Modbus ASCII (pre-installed); custom drivers: Allen-Bradley Data Highway Plus, Mettler Weight Scale, Redundant Enhanced Modbus, Sartorius Weight Scale
Baud Rate 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Parity Even, Odd, None
Data Bits 7 or 8
Stop Bits 1 or 2
Retry Count 0–255
Message Timeout 100–25,500 ms (100 ms increments)
Transmit Delay 0–25,500 ms (100 ms increments)
Send Outputs on Startup Configurable in DeltaV Explorer to send outputs on interface initialization
Modbus Functions - Read: Coils, Input Status, Holding Registers, Input Registers
- Write: Single Coil, Holding Registers (single, register, or dataset mode)
- Input data read as complete dataset for best performance

🔁 Redundancy Features

Feature Details
Redundancy Option Available as redundant pair (model SE4036P2, not SE4006P2) with redundant terminal block
Redundancy Setup Autosensed by DeltaV system; requires slave device with two serial ports
Switchover Triggers Hardware failure, loss of communication (field cable/slave port issues), card removal, control logic, manual switch via Diagnostics Explorer
Switchover Time Minimal, process undisturbed; configurable to resend outputs on switchover
Standby Operation Standby card polls slave device for diagnostic register to confirm readiness
Notification Operator notified of switchover via integrity error alarm on primary card
Replacement Auto-commissioned standby card; replaceable under power in safe areas, follow hazardous area procedures

🌡️ Environmental Specifications

Parameter Specification
Operating Temperature -40 to 70 °C (-40 to 158 °F)
Storage Temperature -40 to 85 °C (-40 to 185 °F)
Relative Humidity 5 to 95%, non-condensing
Airborne Contaminants ISA-S71.04-1985 Class G3
Protection Rating IP20 (KJ3241X1-BK1)
Shock 10 g ½-sine wave for 11 ms
Vibration KJ3241X1-BK1: 1 mm peak-to-peak (5–16 Hz), 0.5 g (16–150 Hz)
KJ4006X1-BD1: 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz)

✅ Certifications

Standard Details
CE EMC - EN 61326-1
FM (USA) FM 3600, FM 3611; Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx/Ex ec IIC Gc (KJ4006X1-BD1)
cFM (Canada) CSA C22.2 No. 213, CSA C22.2 No. 1010.1; Class I, Division 2, Groups A, B, C, D, T4; FM17CA0145U (KJ4006X1-BD1)
ATEX II 3G Ex nA IIC T4 Gc (KJ3241X1-BK1, Nemko No. 11ATEX3029U); II 3G Ex ec IIC Gc (KJ4006X1-BD1, FM19ATEX0173U)
IEC-Ex II 3G Ex ec IIC Gc (KJ4006X1-BD1, IECEx FMG 19.0019U)
UKEX FM21UKEX0017U (KJ4006X1-BD1)
Marine IACS E10, ABS Certificate of Design Assessment, DNV Type Approval Certificate
Installation Instructions Class I Division 2: 12P1293 (KJ3241X1-BK1), 12P5402 (KJ4006X1-BD1)
Zone 2: 12P2046 (KJ3241X1-BK1), 12P5404 (KJ4006X1-BD1)

🛠️ Installation and Configuration

Feature Details
Installation Plugs into 8-wide I/O carrier; no dipswitches; terminal block removable only without I/O card or field wiring (KJ4006X1-BD1)
Removal/Insertion KJ3241X1-BK1: Cannot be removed/inserted with system power energized
KJ4006X1-BD1: Terminal block can be added/removed with system power if no I/O card or field wiring is connected
Configuration Auto-sensed by DeltaV controller; configured via DeltaV Explorer with point-and-click interface
Data Handling - Direct module-to-dataset/register references for control signals
- Marshalling module for multiple registers at 1 DST cost
- SCADA values to workstations/historians without DST consumption
Maintenance No user-serviceable parts; no calibration required

📦 Ordering Information

Description Model Number
S-series Serial Interface Card, 2-ports (Simplex) SE4006P2 (includes KJ3241X1-BK1 and simplex terminal block)
Redundant S-series Serial Interface Card, 2-ports SE4036P2 (includes 2 interface cards and redundant terminal block)
Interface Terminal Block KJ4006X1-BD1

📝 Additional Notes

  • Modbus Support: Pre-installed Modbus RTU and ASCII drivers; supports master or slave configuration per port.
  • Custom Drivers: Available from Emerson (e.g., Allen-Bradley Data Highway Plus, Mettler/Sartorius Weight Scales); contact local sales office for availability.
  • Redundancy Limitation: SE4006P2 is simplex; for redundancy, use SE4036P2. Slave devices must support dual serial ports for redundant operation.
  • DST Usage: Datasets can be referenced directly in control modules or marshalled for cost-effective integration; SCADA tags do not consume DSTs.
  • Hazardous Area Operation: Follow specific installation instructions for Class I Division 2 (12P1293, 12P5402) and Zone 2 (12P2046, 12P5404).
  • Terminal Block Compatibility: KJ4006X1-BD1 key position must match KJ3241X1-BK1 for proper installation.

Download PDF file here:

Click to Download PDF