Skip to product information
1 of 4

Emerson KJ4010X1-BC1 250V 2A Fuse for Fused Terminal Block

Emerson KJ4010X1-BC1 250V 2A Fuse for Fused Terminal Block

  • Manufacturer: Emerson

  • Product No.: KJ4010X1-BC1

  • Condition:1000 in stock

  • Product Type: 250V 2A Fuse for Fused Terminal Block

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Overview

Parameter Details
Product Name 250V 2A Fuse for Fused Terminal Block
Model Number KJ4010X1-BC1
Category DeltaV Electronic Marshalling - CHARM I/O Labeling and Spare Parts
Function Field-replaceable fuse for fused terminal blocks, providing circuit protection and power disconnection for field devices
System Compatibility DeltaV Electronic Marshalling system, used with fused terminal blocks (e.g., SE4502, SE4512, SE4511) on CHARM Baseplates

Hardware Specifications

Specification Value
Type Fuse, field-replaceable
Voltage Rating 250V AC
Current Rating 2A
Quantity Box of 20
Purpose Protects field circuits in fused terminal blocks; allows power disconnection
Associated Components Used with Fused-Injected-Power Terminal Block (SE4502), 3-wire DI Fused-Injected-Power Terminal Block (SE4512), 3-wire AI Fused Injected Power Terminal Block (SE4511)

Environmental Specifications

Parameter Value
Operating Temperature -40 to 70°C (-40 to 158°F); -40 to 60°C (-40 to 140°F) for enclosed installations
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5 to 95%, non-condensing
Protection Rating IP 20
Airborne Contaminants ISA-S71.04-1985 Class G3, conformal coating
Shock 10 g ½-sine wave for 11 ms
Vibration 1 mm peak-to-peak from 2 to 13.2 Hz, 0.7 g from 13.2 to 150 Hz

Certifications

Standard Details
CE EMC: EN 61326-1
FM (USA) FM 3600, FM 3611
CSA CSA C22.2 No. 213-M1987, CSA C22.2 No. 61010-1
ATEX EN60079-0, EN60079-7, EN60079-15
IEC-Ex IEC60079-0, EN60079-7, IEC60079-15
Marine IACS E10, ABS Certificate of Design Assessment, DNV Marine Certificate

Hazardous Area Approvals

Standard Details
FM (USA) Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2: AEx ec IIC Gc T4, AEx ec IIC T4, AEx ec ic IIC Gc T4
cFM (Canada) Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2: Ex ec IIC Gc T4, Ex ec IIC Gc T4, Ex ec ic IIC Gc T4
ATEX II 3G Ex ec IIC T4 Gc, II 3G Ex ec ic IIC T4 Gc

Physical & Installation

Parameter Details
Mounting Installed in fused terminal blocks (SE4502, SE4512, SE4511) on CHARM Baseplates, which are DIN rail-mounted
Installation Type Field-replaceable in terminal blocks; connects to screw cage terminals (0.32-2.5 mm² / 22-14 AWG)
Associated Terminal Blocks Fused-Injected-Power Terminal Block (2 connections, 1 A max at 250V AC); 3-wire DI Fused-Injected-Power Terminal Block (3 connections, 1 A max at 250V AC); 3-wire AI Fused Injected Power Terminal Block (3 connections, 1 A max at 30V DC)
Installation Notes Suitable for hazardous areas (Class I, Division 2, Zone 2); follow installation instructions for hazardous area certifications

Functional Features

Feature
Provides circuit protection for field devices connected to fused terminal blocks
Field-replaceable 2A fuse allows easy maintenance without rewiring
Supports system-powered field circuits (up to 1 A) via injected power bus on CHARM Baseplate
Used with terminal blocks for isolated discrete input/output and analog input CHARMs (e.g., DI 24V DC Isolated, DO 24V DC Isolated, AI 4-20mA HART)
Ensures safe operation in hazardous areas with ATEX/IEC-Ex and FM/CSA certifications
Compatible with CHARM Baseplates, supporting up to 12 CHARMs per baseplate and 8 baseplates per CIOC
Integrated into DeltaV Electronic Marshalling for plug-and-play installation and autosensing

Spare Part Ordering Information

Description Model Number
250V 2A Fuse for Fused Terminal Block; Box of 20 KJ4010X1-BC1

 

View full details

Product Description

Product Overview

Parameter Details
Product Name 250V 2A Fuse for Fused Terminal Block
Model Number KJ4010X1-BC1
Category DeltaV Electronic Marshalling - CHARM I/O Labeling and Spare Parts
Function Field-replaceable fuse for fused terminal blocks, providing circuit protection and power disconnection for field devices
System Compatibility DeltaV Electronic Marshalling system, used with fused terminal blocks (e.g., SE4502, SE4512, SE4511) on CHARM Baseplates

Hardware Specifications

Specification Value
Type Fuse, field-replaceable
Voltage Rating 250V AC
Current Rating 2A
Quantity Box of 20
Purpose Protects field circuits in fused terminal blocks; allows power disconnection
Associated Components Used with Fused-Injected-Power Terminal Block (SE4502), 3-wire DI Fused-Injected-Power Terminal Block (SE4512), 3-wire AI Fused Injected Power Terminal Block (SE4511)

Environmental Specifications

Parameter Value
Operating Temperature -40 to 70°C (-40 to 158°F); -40 to 60°C (-40 to 140°F) for enclosed installations
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5 to 95%, non-condensing
Protection Rating IP 20
Airborne Contaminants ISA-S71.04-1985 Class G3, conformal coating
Shock 10 g ½-sine wave for 11 ms
Vibration 1 mm peak-to-peak from 2 to 13.2 Hz, 0.7 g from 13.2 to 150 Hz

Certifications

Standard Details
CE EMC: EN 61326-1
FM (USA) FM 3600, FM 3611
CSA CSA C22.2 No. 213-M1987, CSA C22.2 No. 61010-1
ATEX EN60079-0, EN60079-7, EN60079-15
IEC-Ex IEC60079-0, EN60079-7, IEC60079-15
Marine IACS E10, ABS Certificate of Design Assessment, DNV Marine Certificate

Hazardous Area Approvals

Standard Details
FM (USA) Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2: AEx ec IIC Gc T4, AEx ec IIC T4, AEx ec ic IIC Gc T4
cFM (Canada) Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2: Ex ec IIC Gc T4, Ex ec IIC Gc T4, Ex ec ic IIC Gc T4
ATEX II 3G Ex ec IIC T4 Gc, II 3G Ex ec ic IIC T4 Gc

Physical & Installation

Parameter Details
Mounting Installed in fused terminal blocks (SE4502, SE4512, SE4511) on CHARM Baseplates, which are DIN rail-mounted
Installation Type Field-replaceable in terminal blocks; connects to screw cage terminals (0.32-2.5 mm² / 22-14 AWG)
Associated Terminal Blocks Fused-Injected-Power Terminal Block (2 connections, 1 A max at 250V AC); 3-wire DI Fused-Injected-Power Terminal Block (3 connections, 1 A max at 250V AC); 3-wire AI Fused Injected Power Terminal Block (3 connections, 1 A max at 30V DC)
Installation Notes Suitable for hazardous areas (Class I, Division 2, Zone 2); follow installation instructions for hazardous area certifications

Functional Features

Feature
Provides circuit protection for field devices connected to fused terminal blocks
Field-replaceable 2A fuse allows easy maintenance without rewiring
Supports system-powered field circuits (up to 1 A) via injected power bus on CHARM Baseplate
Used with terminal blocks for isolated discrete input/output and analog input CHARMs (e.g., DI 24V DC Isolated, DO 24V DC Isolated, AI 4-20mA HART)
Ensures safe operation in hazardous areas with ATEX/IEC-Ex and FM/CSA certifications
Compatible with CHARM Baseplates, supporting up to 12 CHARMs per baseplate and 8 baseplates per CIOC
Integrated into DeltaV Electronic Marshalling for plug-and-play installation and autosensing

Spare Part Ordering Information

Description Model Number
250V 2A Fuse for Fused Terminal Block; Box of 20 KJ4010X1-BC1

 

Download PDF file here:

Click to Download PDF

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)