General Information


Field

Description

Manufacturer

Emerson

Model/Part Number

KJ4002X1-BF2

Description

KJ4002X1-BF1, BF2, BF3, BF4 Bottom Extender Cable Assembly


_



_

Power Specifications


Parameter

Value

LocalBus Circuit Power

12.6 VDC at 15 A


_



_

Environmental Specifications


Parameter

Value

Ambient Temperature

-40°C to +70°C

Shock

10g ½ Sinewave for 11 ms

Vibration

1 mm Peak to Peak (5_16 Hz); 0.5 g (16_150 Hz)

Airborne Contaminants

ISA-S71.04 _1985 Class G3

Relative Humidity

5% to 95% Non-Condensing

IP Rating

IP20


_



_

Important Notes


_

  • Hazardous Area Compliance:

    _


    • Refer to_Document 12P2046___DeltaV_ Scalable Process System Zone 2 Installation Instructions

    • Additional instructions in_Installing Your DeltaV Automation System_manual

  • Installation & Removal:

    _


    • Must not be removed or inserted while power is energized

    • Disconnect only when system is de-energized or area is verified safe

    • Max combined length of I/O carriers and LocalBus extenders:_6.5 meters

    • Interconnecting cables between enclosures must be placed_in conduit

  • Maintenance:

    _


    • Contains_no user-serviceable parts

    • Do not disassemble

    • Calibration not required

_

View full details

Product Description

General Information


Field

Description

Manufacturer

Emerson

Model/Part Number

KJ4002X1-BF2

Description

KJ4002X1-BF1, BF2, BF3, BF4 Bottom Extender Cable Assembly


_



_

Power Specifications


Parameter

Value

LocalBus Circuit Power

12.6 VDC at 15 A


_



_

Environmental Specifications


Parameter

Value

Ambient Temperature

-40°C to +70°C

Shock

10g ½ Sinewave for 11 ms

Vibration

1 mm Peak to Peak (5_16 Hz); 0.5 g (16_150 Hz)

Airborne Contaminants

ISA-S71.04 _1985 Class G3

Relative Humidity

5% to 95% Non-Condensing

IP Rating

IP20


_



_

Important Notes


_

  • Hazardous Area Compliance:

    _


    • Refer to_Document 12P2046___DeltaV_ Scalable Process System Zone 2 Installation Instructions

    • Additional instructions in_Installing Your DeltaV Automation System_manual

  • Installation & Removal:

    _


    • Must not be removed or inserted while power is energized

    • Disconnect only when system is de-energized or area is verified safe

    • Max combined length of I/O carriers and LocalBus extenders:_6.5 meters

    • Interconnecting cables between enclosures must be placed_in conduit

  • Maintenance:

    _


    • Contains_no user-serviceable parts

    • Do not disassemble

    • Calibration not required