General Information


Field

Description

Manufacturer

Emerson

Model/Part Number

KJ4001X1-BA3 VE3051C0

Description

2-Wide Power/Controller Carrier


 



 

Power Specifications


Parameter

Value

Input Power

30 VDC @ 8 A


 



 

Environmental Specifications


Parameter

Value

Ambient Temperature

-40 °C to +70 °C

Shock

10 g ½ sinewave for 11 ms

Vibration

1 mm peak-to-peak (2–13.2 Hz); 0.7 g (13.2–150 Hz)

Airborne Contaminants

ISA-S71.04 –1985 Class G3

Relative Humidity

5% to 95% non-condensing


 



 

Installation and Operation Notes


 

  • Hazardous Area Compliance:

     


    • Refer to Document 12P2046 (DeltaV™ Zone 2 Installation Instructions)

    • Also see DeltaV™ M-Series Hardware Installation and Reference manual

  • Removal and Insertion:

     


    • Power must be OFF during removal/insertion

    • Disconnect all carriers and LocalBus Extender cables only when de-energized

  • Carrier Guidelines:

     


    • A module cover (KJ4001X1-FA1) is required for any unoccupied location

    • Combined length of I/O carriers and LocalBus Extenders must not exceed 6.5 meters

    • Cables between enclosures must be in conduit


 



 

Maintenance and Adjustment


 

  • No user-serviceable parts

  • Disassembly is not permitted

  • Calibration not required

 

View full details

Product Description

General Information


Field

Description

Manufacturer

Emerson

Model/Part Number

KJ4001X1-BA3 VE3051C0

Description

2-Wide Power/Controller Carrier


 



 

Power Specifications


Parameter

Value

Input Power

30 VDC @ 8 A


 



 

Environmental Specifications


Parameter

Value

Ambient Temperature

-40 °C to +70 °C

Shock

10 g ½ sinewave for 11 ms

Vibration

1 mm peak-to-peak (2–13.2 Hz); 0.7 g (13.2–150 Hz)

Airborne Contaminants

ISA-S71.04 –1985 Class G3

Relative Humidity

5% to 95% non-condensing


 



 

Installation and Operation Notes


 

  • Hazardous Area Compliance:

     


    • Refer to Document 12P2046 (DeltaV™ Zone 2 Installation Instructions)

    • Also see DeltaV™ M-Series Hardware Installation and Reference manual

  • Removal and Insertion:

     


    • Power must be OFF during removal/insertion

    • Disconnect all carriers and LocalBus Extender cables only when de-energized

  • Carrier Guidelines:

     


    • A module cover (KJ4001X1-FA1) is required for any unoccupied location

    • Combined length of I/O carriers and LocalBus Extenders must not exceed 6.5 meters

    • Cables between enclosures must be in conduit


 



 

Maintenance and Adjustment


 

  • No user-serviceable parts

  • Disassembly is not permitted

  • Calibration not required

 