Skip to product information
1 of 8

Emerson KJ2221X1-EA1 SISNet Repeater Carrier

Emerson KJ2221X1-EA1 SISNet Repeater Carrier

  • Manufacturer: Emerson

  • Product No.: KJ2221X1-EA1

  • Condition:1000 in stock

  • Product Type: SISNet Repeater Carrier

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

General Information


Field

Description

Manufacturer

Emerson

Model/Part Number

KJ2221X1-EA1

Description

SISNet Repeater Carrier


 



 

Power Specifications


Parameter

Value

Local Bus Power

12.6 VDC at 8 A


 



 

Environmental Specifications


Parameter

Value

Ambient Temperature

–40°C to +70°C

Shock

10 g half-sine wave for 11 ms

Vibration

1 mm peak-to-peak (2–13.2 Hz); 0.7 g (13.2–150 Hz)

Airborne Contaminants

ISA-S71.04 –1985, Class G3

Relative Humidity

5% to 95% Non-Condensing


 



 

Installation and Operation Notes


 

  • Hazardous Area Compliance:

     


    • Follow Document 12P2046 (DeltaV™ Zone 2 Installation Instructions).

    • Also refer to the DeltaV™ M-Series Hardware Installation and Reference manual.

  • Removal/Insertion Guidelines:

     


    • Cannot be removed or inserted with system power energized unless in a non-hazardous area.

    • Power must be de-energized before disconnecting any carriers or LocalBus Extender cables.


 



 

Maintenance and Adjustment


 

  • No user-serviceable parts

  • Do not disassemble

  • Calibration not required

 

View full details

Product Description

General Information


Field

Description

Manufacturer

Emerson

Model/Part Number

KJ2221X1-EA1

Description

SISNet Repeater Carrier


 



 

Power Specifications


Parameter

Value

Local Bus Power

12.6 VDC at 8 A


 



 

Environmental Specifications


Parameter

Value

Ambient Temperature

–40°C to +70°C

Shock

10 g half-sine wave for 11 ms

Vibration

1 mm peak-to-peak (2–13.2 Hz); 0.7 g (13.2–150 Hz)

Airborne Contaminants

ISA-S71.04 –1985, Class G3

Relative Humidity

5% to 95% Non-Condensing


 



 

Installation and Operation Notes


 

  • Hazardous Area Compliance:

     


    • Follow Document 12P2046 (DeltaV™ Zone 2 Installation Instructions).

    • Also refer to the DeltaV™ M-Series Hardware Installation and Reference manual.

  • Removal/Insertion Guidelines:

     


    • Cannot be removed or inserted with system power energized unless in a non-hazardous area.

    • Power must be de-energized before disconnecting any carriers or LocalBus Extender cables.


 



 

Maintenance and Adjustment


 

  • No user-serviceable parts

  • Do not disassemble

  • Calibration not required

 