Skip to product information
1 of 9

Emerson ‎‎KJ2201X1-BA1 12P3162X122 Logic Solver – SLS 1508

Emerson ‎‎KJ2201X1-BA1 12P3162X122 Logic Solver – SLS 1508

  • Manufacturer: Emerson

  • Product No.: 12P3162X122

  • Condition:1000 in stock

  • Product Type: Logic Solver – SLS 1508

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

General Information


Field

Description

Manufacturer

Emerson

Model/Part Number

KJ2201X1-BA1 (12P3162X122)

Description

Logic Solver – SLS 1508


 



 

Power Specifications


Parameter

Value

Input Power

24 VDC, 1 A

Field Power

4 A (maximum)


 



 

Environmental Specifications


Parameter

Value

Ambient Temperature

–40°C to +70°C

Shock

10 g half-sine wave for 11 ms

Vibration

1 mm peak-to-peak (5–16 Hz), 0.5 g (16–150 Hz)

Airborne Contaminants

ISA-S71.04 –1985, Class G3

Relative Humidity

5% to 95% Non-Condensing


 



 

Installation and Operation Notes


 

  • Hazardous Area Instructions:

     


    • Refer to Document 12P2046 (DeltaV™ Zone 2 Installation Instructions).

    • Additional instructions are in the DeltaV™ Safety Instrumented System Hardware manual and the DeltaV™ Safety Instrumented System Safety manual.

  • Removal/Insertion Guidelines:

     


    • Unit cannot be removed or inserted with system power energized.


 



 

Maintenance and Adjustment


 

  • No user-serviceable parts

  • Do not disassemble

  • Calibration not required


 

View full details

Product Description

General Information


Field

Description

Manufacturer

Emerson

Model/Part Number

KJ2201X1-BA1 (12P3162X122)

Description

Logic Solver – SLS 1508


 



 

Power Specifications


Parameter

Value

Input Power

24 VDC, 1 A

Field Power

4 A (maximum)


 



 

Environmental Specifications


Parameter

Value

Ambient Temperature

–40°C to +70°C

Shock

10 g half-sine wave for 11 ms

Vibration

1 mm peak-to-peak (5–16 Hz), 0.5 g (16–150 Hz)

Airborne Contaminants

ISA-S71.04 –1985, Class G3

Relative Humidity

5% to 95% Non-Condensing


 



 

Installation and Operation Notes


 

  • Hazardous Area Instructions:

     


    • Refer to Document 12P2046 (DeltaV™ Zone 2 Installation Instructions).

    • Additional instructions are in the DeltaV™ Safety Instrumented System Hardware manual and the DeltaV™ Safety Instrumented System Safety manual.

  • Removal/Insertion Guidelines:

     


    • Unit cannot be removed or inserted with system power energized.


 



 

Maintenance and Adjustment


 

  • No user-serviceable parts

  • Do not disassemble

  • Calibration not required


 

Download PDF file here: