Skip to product information
1 of 6

Emerson KC3010X1-BK1 AI 16-Channel 4–20 mA HART Plus Card

Emerson KC3010X1-BK1 AI 16-Channel 4–20 mA HART Plus Card

  • Manufacturer: Emerson

  • Product No.: KC3010X1-BK1

  • Condition:1000 in stock

  • Product Type: AI 16-Channel 4–20 mA HART Plus Card

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

General Information


Field

Description

Manufacturer

Emerson

Model/Part Number

KC3010X1-BK1

Description

AI 16-Channel 4–20 mA HART Plus Card


 



 

Power Specifications


Power Type

Value

Local Bus Power

12 VDC @ 150 mA

Bussed Field Power

24 VDC @ 500 mA

Field Circuit

24 VDC @ 30 mA/Ch.


 



 

Environmental Specifications


Parameter

Value

Ambient Temperature

–40 °C to +70 °C

Shock

10 g half-sine wave for 11 ms

Vibration

1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz)

Airborne Contaminants

ISA-S71.04 –1985, Class G3

Relative Humidity

5% to 95% Non-Condensing

Terminal Block Key Position

A6


 



 

Installation and Operation Notes


 

  • Hazardous Area Installation:

     


    • Must follow Document 12P5404 (DeltaV™ S-series Zone 2 Installation Instructions)

    • Additional guidance in DeltaV™ S-series and CHARMs Hardware Installation manual

  • Removal/Insertion Rules:

     


    • Field power must be removed before removal/insertion

    • Cannot be removed or inserted with system power energized

    • I/O Loop Assessment required for all energy-limited nodes

  • Rotary Keying System:

     


    • Ensures correct matching between I/O card and terminal block

    • Terminal block must be keyed appropriately


 



 

Maintenance and Adjustment


 

  • No user-serviceable parts

  • Do not disassemble

  • Calibration not required


 

View full details

Product Description

General Information


Field

Description

Manufacturer

Emerson

Model/Part Number

KC3010X1-BK1

Description

AI 16-Channel 4–20 mA HART Plus Card


 



 

Power Specifications


Power Type

Value

Local Bus Power

12 VDC @ 150 mA

Bussed Field Power

24 VDC @ 500 mA

Field Circuit

24 VDC @ 30 mA/Ch.


 



 

Environmental Specifications


Parameter

Value

Ambient Temperature

–40 °C to +70 °C

Shock

10 g half-sine wave for 11 ms

Vibration

1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz)

Airborne Contaminants

ISA-S71.04 –1985, Class G3

Relative Humidity

5% to 95% Non-Condensing

Terminal Block Key Position

A6


 



 

Installation and Operation Notes


 

  • Hazardous Area Installation:

     


    • Must follow Document 12P5404 (DeltaV™ S-series Zone 2 Installation Instructions)

    • Additional guidance in DeltaV™ S-series and CHARMs Hardware Installation manual

  • Removal/Insertion Rules:

     


    • Field power must be removed before removal/insertion

    • Cannot be removed or inserted with system power energized

    • I/O Loop Assessment required for all energy-limited nodes

  • Rotary Keying System:

     


    • Ensures correct matching between I/O card and terminal block

    • Terminal block must be keyed appropriately


 



 

Maintenance and Adjustment


 

  • No user-serviceable parts

  • Do not disassemble

  • Calibration not required


 

Download PDF file here:

Click to Download PDF