Product Description
General Information
Field |
Description |
---|---|
Manufacturer |
Emerson |
Model/Part Number |
EZ1900-040 |
Description |
Eddy Current Sensor Extension Cable, No Armor, 4 m |
Performance Specifications
Parameter |
Value |
---|---|
Linear Measurement Range |
2 mm (80 mils) |
Initial Air Gap |
0.5 mm (20 mils) |
Incremental Scale Factor (ISF) |
API: 7.87 V/mm (199.9 mV/mil) ±5%ISO: 8 V/mm (203.2 mV/mil) ±5% |
Deviation from Best Fit Straight Line (DSL) |
±0.025 mm (±1 mil) from 0 to 45°C (32–113°F) |
Measuring Target Minimum Size |
14 mm (0.55”) minimum, 20 mm (0.79”) recommended |
Minimum Shaft Diameter |
20 mm (0.79”) minimum, 25 mm (0.98”) recommended |
Target Material |
Ferromagnetic Steels (e.g., 42CrMo4, AISI/SAE 4140, and others) |
Environmental Specifications
Parameter |
Value |
---|---|
Protection Class |
IP67 (default), IP68 (if DOC-TEST ordered) |
Operating Temperature |
Sensor + 1m Cable: –35°C to +180°C (–31°F to 356°F) Cable & Connector: –35°C to +150°C (–31°F to 302°F) |
Differential Pressure Resistance |
10,000 hPa (145 psi) up to 120°C (248°F) |
Material |
Sensor Tip: GF30 (glass-fiber reinforced PEEK) Case: Stainless Steel Cable: FEP Connector: Brass, nickel-plated |
Weight |
Approx. 100 g (3.53 oz) (sensor with 1 m cable) |
Ordering Information
Model No. |
Armor |
Cable Length |
---|---|---|
EZ1900-XXX |
No |
Selectable: 2.0 m to 9.5 m (Standard)14.0 m, 29.0 m (On Request) |
EZ1901-XXX |
Yes |
(Armored version) |
Example:
EZ1900-040 → Eddy Current Sensor Extension Cable, No Armor, 4 m