Full-Scale Option (A) |
25: 0-25 mils pp (0-635 μm pp) |
System Length Option (B) |
50: 5.0 meters (16.4 feet) |
Mounting Option (C) |
02: Bulkhead screws |
Agency Approval Option (D) |
00: Not required |
Output Signal |
4-20 mA loop-powered, proportional to peak thrust position; fault indication at < 2 mA or > 22 mA |
Power Supply |
+12 to +35 Vdc input |
Input |
Accepts one non-contacting 3300 NSv Proximity Probe and extension cable |
Measurement Range |
0-25 mils pp (0-635 μm pp) |
Frequency Response |
0 to 10,000 Hz (0 to 600,000 cpm) |
Accuracy |
±2% of full scale |
Operating Temperature |
-30°C to +65°C (-22°F to +149°F) |
Storage Temperature |
-40°C to +85°C (-40°F to +185°F) |
Relative Humidity |
Up to 95%, non-condensing |
Dimensions |
Approximately 16 cm x 16 cm x 12 cm |
Weight |
0.8 kg |
Approvals |
CSA/NRTL/C Class I Div 2, ATEX/IECEx (optional) |
Installation |
Bulkhead screws; simple installation for quick integration |