Skip to product information
1 of 3

Bently Nevada 3500/05 Mini Rack | 7-Slot Panel Mount 3500/05-02-04

Bently Nevada 3500/05 Mini Rack | 7-Slot Panel Mount 3500/05-02-04

  • Manufacturer: Bently Nevada

  • Product No.: 3500/05-02-04-00-00-01

  • Condition:1000 in stock

  • Product Type: Monitoring System Rack

  • Product Origin: 3500/05-02-04-00-00-01

  • Payment: T/T, Western Union

  • Weight: 4000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

🏗️ Compact Infrastructure for Mission-Critical Machinery Protection

The Bently Nevada 3500/05 Mini Rack (Model 3500/05-02-04-00-00-01) delivers enterprise-grade monitoring infrastructure in a space-efficient 12-inch form factor. Engineered for installations where panel real estate is limited yet monitoring requirements remain uncompromising, this 7-slot mini rack provides the backbone for complete vibration, temperature, and process monitoring systems.

💡 Why Choose the Mini Rack Configuration?

✓ Space Optimization: 50% smaller footprint than full-size racks—ideal for skid-mounted packages, offshore platforms, and retrofit installations where panel space is constrained.

✓ Cost Efficiency: Right-sized for single-train monitoring (1-3 machines)—avoid over-provisioning while maintaining expansion capability for future growth.

✓ Panel Integration: Flush-mount design integrates seamlessly into control cabinets and MCC panels—no external rack mounting hardware required.

✓ Modular Scalability: Deploy multiple mini racks for distributed monitoring architectures—each rack dedicated to a specific process unit or machine train.

📐 System Architecture & Specifications

Component Specification
Rack Size 12-inch Mini Rack (Option 02)
Module Capacity 7 full-height slots (14 half-height modules possible)
Mounting Style Panel Mount (Option 04) - flush installation
Hazardous Area Rating Standard (Option 00) - general industrial use
Compliance Certification CE Marked (Option 01) - European conformity
Power Supply Slots 2 dedicated half-height slots (leftmost positions)
Backplane Communication Proprietary TDI (Transient Data Interface) bus
Weight (Empty) 4.0 kg (8.8 lbs) approximate
Dimensions (W×H×D) 305 × 267 × 241 mm (12" × 10.5" × 9.5")
Panel Cutout Required 292 × 254 mm (11.5" × 10.0") typical

🎯 Typical System Configurations

Configuration 1: Single Compressor Train Monitoring

Slot 1-2: 3500/15 Dual Power Supply (AC+DC redundancy)
Slot 3: 3500/22M TDI Module (transient data capture)
Slot 4-5: 3500/42M Proximitor Monitors (4 radial probes + 2 thrust)
Slot 6: 3500/25 Keyphasor Module (timing reference)
Slot 7: 3500/92 Communication Gateway (DCS integration)

Application: Complete protection for single-stage centrifugal compressor with radial vibration, thrust position, and speed monitoring.

Configuration 2: Multi-Machine Temperature Monitoring

table>

Application: Bearing temperature surveillance for multiple pumps, motors, or gearboxes in a process unit.

Configuration 3: Hybrid Vibration & Process Monitoring

Slot 1-2: 3500/15 Single Power Supply (AC or DC)
Slot 3-6: 3500/60 Temperature Monitors (64 RTD inputs total)
Slot 7: 3500/33 Relay Output Module (alarm annunciation)
Slot 1-2: 3500/15 Dual Power Supply
Slot 3: 3500/40M Proximitor Monitor (shaft vibration)
Slot 4: 3500/45 Position Monitor (valve position feedback)
Slot 5: 3500/64M Dynamic Pressure Monitor (combustion dynamics)
Slot 6: 3500/53 Overspeed Detection System
Slot 7: 3500/20 RIM I/O Module (shutdown logic)

Application: Gas turbine protection with vibration, overspeed, and combustion monitoring integrated into single rack.

🔧 Installation & Integration Guidelines

Panel Preparation Requirements:

  1. Cutout Dimensions: Create 292 mm × 254 mm (11.5" × 10.0") opening in panel—verify clearances before cutting
  2. Panel Thickness: Suitable for 1.5-3.0 mm (16-20 gauge) steel or aluminum panels
  3. Rear Clearance: Ensure minimum 300 mm (12") depth behind panel for module insertion and cable routing
  4. Ventilation: Provide 100 mm (4") clearance above and below rack for convection cooling—no forced air required
  5. Grounding: Connect rack chassis to panel ground using M6 grounding stud on rear panel

Module Installation Sequence:

  1. Power Supplies First: Install 3500/15 power modules in leftmost slots (positions 1-2)—these must be installed before other modules
  2. TDI Module: If using transient data capture, install 3500/22M immediately to the right of power supplies
  3. Monitor Modules: Populate remaining slots with monitoring modules in any order—backplane auto-detects module types
  4. I/O Modules: Attach external I/O modules to rear of each monitor—verify correct I/O type for application
  5. Power-Up Sequence: Apply power—all modules should illuminate OK LEDs within 30 seconds

Cable Management Best Practices:

  • Route field wiring through bottom cable entry—use cable glands rated for panel environment
  • Separate power cables from signal cables—maintain 150 mm (6") minimum spacing
  • Label all cables at both ends with module slot number and channel designation
  • Use strain relief on all external connections to prevent connector damage from cable pull

⚠️ Critical Design Considerations

Consideration Requirement
Power Budget Maximum 7 full-height modules @ ~5W each = 35W total—single 3500/15 power supply (75W capacity) is sufficient
Ambient Temperature -30°C to +65°C operating range—derate above 55°C or provide forced cooling
Humidity Limits 95% RH non-condensing—use panel heaters in high-humidity environments to prevent condensation
Vibration Exposure Rack is rated for 0.5g continuous vibration—avoid mounting directly on reciprocating equipment
Expansion Limitations Cannot be expanded beyond 7 slots—plan for future growth by deploying full-size rack (14 slots) if expansion likely

📋 Model Code Breakdown: 3500/05-02-04-00-00-01

Position 1 (02): 12-inch Mini Rack (7 module slots)
Position 2 (04): Panel Mount configuration (flush installation)
Position 3 (00): No hazardous area certification (standard industrial)
Position 4 (00): Reserved (no special options)
Position 5 (01): CE Compliance (European conformity marking)

🔄 Upgrade & Migration Paths

From Legacy 3300 Systems: The 3500/05 mini rack provides a compact migration path from 3300 XL monitoring systems. Existing proximity probes, extension cables, and transducers are fully compatible—only monitor modules and rack infrastructure require replacement.

To Full-Size Rack: If monitoring requirements grow beyond 7 slots, modules can be relocated to a 3500/05-01 full-size rack (14 slots) without reconfiguration—all settings and alarm parameters transfer via configuration software.

Distributed Architecture: Deploy multiple mini racks for geographically distributed monitoring—each rack operates independently with local alarm outputs, or network via 3500/92 gateways for centralized SCADA integration.

📦 Package Contents & Accessories

✅ Included Components:

  • 3500/05 Mini Rack chassis with backplane
  • Panel mounting hardware (screws and brackets)
  • Grounding lug and hardware
  • Slot cover plates (for unused positions)
  • Installation manual and wiring diagrams

🛒 Required Separately:

  • 3500/15 Power Supply modules (1 or 2)
  • 3500 Series monitor modules per application
  • I/O modules for each monitor
  • Field wiring and cable glands
  • 3500 Rack Configuration Software license

✅ Quality & Compliance Certifications

🇪🇺

CE Marked

🏭

ISO 9001 Certified

EMC Compliant

🎯 Engineering Support Available: Our machinery protection specialists provide complimentary system design assistance including module selection, power budget calculations, panel layout optimization, and configuration file development. Contact us for pre-purchase consultation or post-installation commissioning support.

View full details

Product Description

🏗️ Compact Infrastructure for Mission-Critical Machinery Protection

The Bently Nevada 3500/05 Mini Rack (Model 3500/05-02-04-00-00-01) delivers enterprise-grade monitoring infrastructure in a space-efficient 12-inch form factor. Engineered for installations where panel real estate is limited yet monitoring requirements remain uncompromising, this 7-slot mini rack provides the backbone for complete vibration, temperature, and process monitoring systems.

💡 Why Choose the Mini Rack Configuration?

✓ Space Optimization: 50% smaller footprint than full-size racks—ideal for skid-mounted packages, offshore platforms, and retrofit installations where panel space is constrained.

✓ Cost Efficiency: Right-sized for single-train monitoring (1-3 machines)—avoid over-provisioning while maintaining expansion capability for future growth.

✓ Panel Integration: Flush-mount design integrates seamlessly into control cabinets and MCC panels—no external rack mounting hardware required.

✓ Modular Scalability: Deploy multiple mini racks for distributed monitoring architectures—each rack dedicated to a specific process unit or machine train.

📐 System Architecture & Specifications

Component Specification
Rack Size 12-inch Mini Rack (Option 02)
Module Capacity 7 full-height slots (14 half-height modules possible)
Mounting Style Panel Mount (Option 04) - flush installation
Hazardous Area Rating Standard (Option 00) - general industrial use
Compliance Certification CE Marked (Option 01) - European conformity
Power Supply Slots 2 dedicated half-height slots (leftmost positions)
Backplane Communication Proprietary TDI (Transient Data Interface) bus
Weight (Empty) 4.0 kg (8.8 lbs) approximate
Dimensions (W×H×D) 305 × 267 × 241 mm (12" × 10.5" × 9.5")
Panel Cutout Required 292 × 254 mm (11.5" × 10.0") typical

🎯 Typical System Configurations

Configuration 1: Single Compressor Train Monitoring

Slot 1-2: 3500/15 Dual Power Supply (AC+DC redundancy)
Slot 3: 3500/22M TDI Module (transient data capture)
Slot 4-5: 3500/42M Proximitor Monitors (4 radial probes + 2 thrust)
Slot 6: 3500/25 Keyphasor Module (timing reference)
Slot 7: 3500/92 Communication Gateway (DCS integration)

Application: Complete protection for single-stage centrifugal compressor with radial vibration, thrust position, and speed monitoring.

Configuration 2: Multi-Machine Temperature Monitoring

table>

Application: Bearing temperature surveillance for multiple pumps, motors, or gearboxes in a process unit.

Configuration 3: Hybrid Vibration & Process Monitoring

Slot 1-2: 3500/15 Single Power Supply (AC or DC)
Slot 3-6: 3500/60 Temperature Monitors (64 RTD inputs total)
Slot 7: 3500/33 Relay Output Module (alarm annunciation)
Slot 1-2: 3500/15 Dual Power Supply
Slot 3: 3500/40M Proximitor Monitor (shaft vibration)
Slot 4: 3500/45 Position Monitor (valve position feedback)
Slot 5: 3500/64M Dynamic Pressure Monitor (combustion dynamics)
Slot 6: 3500/53 Overspeed Detection System
Slot 7: 3500/20 RIM I/O Module (shutdown logic)

Application: Gas turbine protection with vibration, overspeed, and combustion monitoring integrated into single rack.

🔧 Installation & Integration Guidelines

Panel Preparation Requirements:

  1. Cutout Dimensions: Create 292 mm × 254 mm (11.5" × 10.0") opening in panel—verify clearances before cutting
  2. Panel Thickness: Suitable for 1.5-3.0 mm (16-20 gauge) steel or aluminum panels
  3. Rear Clearance: Ensure minimum 300 mm (12") depth behind panel for module insertion and cable routing
  4. Ventilation: Provide 100 mm (4") clearance above and below rack for convection cooling—no forced air required
  5. Grounding: Connect rack chassis to panel ground using M6 grounding stud on rear panel

Module Installation Sequence:

  1. Power Supplies First: Install 3500/15 power modules in leftmost slots (positions 1-2)—these must be installed before other modules
  2. TDI Module: If using transient data capture, install 3500/22M immediately to the right of power supplies
  3. Monitor Modules: Populate remaining slots with monitoring modules in any order—backplane auto-detects module types
  4. I/O Modules: Attach external I/O modules to rear of each monitor—verify correct I/O type for application
  5. Power-Up Sequence: Apply power—all modules should illuminate OK LEDs within 30 seconds

Cable Management Best Practices:

  • Route field wiring through bottom cable entry—use cable glands rated for panel environment
  • Separate power cables from signal cables—maintain 150 mm (6") minimum spacing
  • Label all cables at both ends with module slot number and channel designation
  • Use strain relief on all external connections to prevent connector damage from cable pull

⚠️ Critical Design Considerations

Consideration Requirement
Power Budget Maximum 7 full-height modules @ ~5W each = 35W total—single 3500/15 power supply (75W capacity) is sufficient
Ambient Temperature -30°C to +65°C operating range—derate above 55°C or provide forced cooling
Humidity Limits 95% RH non-condensing—use panel heaters in high-humidity environments to prevent condensation
Vibration Exposure Rack is rated for 0.5g continuous vibration—avoid mounting directly on reciprocating equipment
Expansion Limitations Cannot be expanded beyond 7 slots—plan for future growth by deploying full-size rack (14 slots) if expansion likely

📋 Model Code Breakdown: 3500/05-02-04-00-00-01

Position 1 (02): 12-inch Mini Rack (7 module slots)
Position 2 (04): Panel Mount configuration (flush installation)
Position 3 (00): No hazardous area certification (standard industrial)
Position 4 (00): Reserved (no special options)
Position 5 (01): CE Compliance (European conformity marking)

🔄 Upgrade & Migration Paths

From Legacy 3300 Systems: The 3500/05 mini rack provides a compact migration path from 3300 XL monitoring systems. Existing proximity probes, extension cables, and transducers are fully compatible—only monitor modules and rack infrastructure require replacement.

To Full-Size Rack: If monitoring requirements grow beyond 7 slots, modules can be relocated to a 3500/05-01 full-size rack (14 slots) without reconfiguration—all settings and alarm parameters transfer via configuration software.

Distributed Architecture: Deploy multiple mini racks for geographically distributed monitoring—each rack operates independently with local alarm outputs, or network via 3500/92 gateways for centralized SCADA integration.

📦 Package Contents & Accessories

✅ Included Components:

  • 3500/05 Mini Rack chassis with backplane
  • Panel mounting hardware (screws and brackets)
  • Grounding lug and hardware
  • Slot cover plates (for unused positions)
  • Installation manual and wiring diagrams

🛒 Required Separately:

  • 3500/15 Power Supply modules (1 or 2)
  • 3500 Series monitor modules per application
  • I/O modules for each monitor
  • Field wiring and cable glands
  • 3500 Rack Configuration Software license

✅ Quality & Compliance Certifications

🇪🇺

CE Marked

🏭

ISO 9001 Certified

EMC Compliant

🎯 Engineering Support Available: Our machinery protection specialists provide complimentary system design assistance including module selection, power budget calculations, panel layout optimization, and configuration file development. Contact us for pre-purchase consultation or post-installation commissioning support.

Download PDF file here:

Click to Download PDF