Product Description
🏗️ Compact Infrastructure for Mission-Critical Machinery Protection
The Bently Nevada 3500/05 Mini Rack (Model 3500/05-02-04-00-00-01) delivers enterprise-grade monitoring infrastructure in a space-efficient 12-inch form factor. Engineered for installations where panel real estate is limited yet monitoring requirements remain uncompromising, this 7-slot mini rack provides the backbone for complete vibration, temperature, and process monitoring systems.
💡 Why Choose the Mini Rack Configuration?
✓ Space Optimization: 50% smaller footprint than full-size racks—ideal for skid-mounted packages, offshore platforms, and retrofit installations where panel space is constrained.
✓ Cost Efficiency: Right-sized for single-train monitoring (1-3 machines)—avoid over-provisioning while maintaining expansion capability for future growth.
✓ Panel Integration: Flush-mount design integrates seamlessly into control cabinets and MCC panels—no external rack mounting hardware required.
✓ Modular Scalability: Deploy multiple mini racks for distributed monitoring architectures—each rack dedicated to a specific process unit or machine train.
📐 System Architecture & Specifications
| Component | Specification |
|---|---|
| Rack Size | 12-inch Mini Rack (Option 02) |
| Module Capacity | 7 full-height slots (14 half-height modules possible) |
| Mounting Style | Panel Mount (Option 04) - flush installation |
| Hazardous Area Rating | Standard (Option 00) - general industrial use |
| Compliance Certification | CE Marked (Option 01) - European conformity |
| Power Supply Slots | 2 dedicated half-height slots (leftmost positions) |
| Backplane Communication | Proprietary TDI (Transient Data Interface) bus |
| Weight (Empty) | 4.0 kg (8.8 lbs) approximate |
| Dimensions (W×H×D) | 305 × 267 × 241 mm (12" × 10.5" × 9.5") |
| Panel Cutout Required | 292 × 254 mm (11.5" × 10.0") typical |
🎯 Typical System Configurations
Configuration 1: Single Compressor Train Monitoring
| Slot 1-2: | 3500/15 Dual Power Supply (AC+DC redundancy) |
| Slot 3: | 3500/22M TDI Module (transient data capture) |
| Slot 4-5: | 3500/42M Proximitor Monitors (4 radial probes + 2 thrust) |
| Slot 6: | 3500/25 Keyphasor Module (timing reference) |
| Slot 7: | 3500/92 Communication Gateway (DCS integration) |
Application: Complete protection for single-stage centrifugal compressor with radial vibration, thrust position, and speed monitoring.
Configuration 2: Multi-Machine Temperature Monitoring
| Slot 1-2: | 3500/15 Single Power Supply (AC or DC) |
| Slot 3-6: | 3500/60 Temperature Monitors (64 RTD inputs total) |
| Slot 7: | 3500/33 Relay Output Module (alarm annunciation) |
| Slot 1-2: | 3500/15 Dual Power Supply |
| Slot 3: | 3500/40M Proximitor Monitor (shaft vibration) |
| Slot 4: | 3500/45 Position Monitor (valve position feedback) |
| Slot 5: | 3500/64M Dynamic Pressure Monitor (combustion dynamics) |
| Slot 6: | 3500/53 Overspeed Detection System |
| Slot 7: | 3500/20 RIM I/O Module (shutdown logic) |
Application: Gas turbine protection with vibration, overspeed, and combustion monitoring integrated into single rack.
🔧 Installation & Integration Guidelines
Panel Preparation Requirements:
- Cutout Dimensions: Create 292 mm × 254 mm (11.5" × 10.0") opening in panel—verify clearances before cutting
- Panel Thickness: Suitable for 1.5-3.0 mm (16-20 gauge) steel or aluminum panels
- Rear Clearance: Ensure minimum 300 mm (12") depth behind panel for module insertion and cable routing
- Ventilation: Provide 100 mm (4") clearance above and below rack for convection cooling—no forced air required
- Grounding: Connect rack chassis to panel ground using M6 grounding stud on rear panel
Module Installation Sequence:
- Power Supplies First: Install 3500/15 power modules in leftmost slots (positions 1-2)—these must be installed before other modules
- TDI Module: If using transient data capture, install 3500/22M immediately to the right of power supplies
- Monitor Modules: Populate remaining slots with monitoring modules in any order—backplane auto-detects module types
- I/O Modules: Attach external I/O modules to rear of each monitor—verify correct I/O type for application
- Power-Up Sequence: Apply power—all modules should illuminate OK LEDs within 30 seconds
Cable Management Best Practices:
- Route field wiring through bottom cable entry—use cable glands rated for panel environment
- Separate power cables from signal cables—maintain 150 mm (6") minimum spacing
- Label all cables at both ends with module slot number and channel designation
- Use strain relief on all external connections to prevent connector damage from cable pull
⚠️ Critical Design Considerations
| Consideration | Requirement |
|---|---|
| Power Budget | Maximum 7 full-height modules @ ~5W each = 35W total—single 3500/15 power supply (75W capacity) is sufficient |
| Ambient Temperature | -30°C to +65°C operating range—derate above 55°C or provide forced cooling |
| Humidity Limits | 95% RH non-condensing—use panel heaters in high-humidity environments to prevent condensation |
| Vibration Exposure | Rack is rated for 0.5g continuous vibration—avoid mounting directly on reciprocating equipment |
| Expansion Limitations | Cannot be expanded beyond 7 slots—plan for future growth by deploying full-size rack (14 slots) if expansion likely |
📋 Model Code Breakdown: 3500/05-02-04-00-00-01
| Position 1 (02): | 12-inch Mini Rack (7 module slots) |
| Position 2 (04): | Panel Mount configuration (flush installation) |
| Position 3 (00): | No hazardous area certification (standard industrial) |
| Position 4 (00): | Reserved (no special options) |
| Position 5 (01): | CE Compliance (European conformity marking) |
🔄 Upgrade & Migration Paths
From Legacy 3300 Systems: The 3500/05 mini rack provides a compact migration path from 3300 XL monitoring systems. Existing proximity probes, extension cables, and transducers are fully compatible—only monitor modules and rack infrastructure require replacement.
To Full-Size Rack: If monitoring requirements grow beyond 7 slots, modules can be relocated to a 3500/05-01 full-size rack (14 slots) without reconfiguration—all settings and alarm parameters transfer via configuration software.
Distributed Architecture: Deploy multiple mini racks for geographically distributed monitoring—each rack operates independently with local alarm outputs, or network via 3500/92 gateways for centralized SCADA integration.
📦 Package Contents & Accessories
✅ Included Components:
- 3500/05 Mini Rack chassis with backplane
- Panel mounting hardware (screws and brackets)
- Grounding lug and hardware
- Slot cover plates (for unused positions)
- Installation manual and wiring diagrams
🛒 Required Separately:
- 3500/15 Power Supply modules (1 or 2)
- 3500 Series monitor modules per application
- I/O modules for each monitor
- Field wiring and cable glands
- 3500 Rack Configuration Software license
✅ Quality & Compliance Certifications
🇪🇺
CE Marked
🏭
ISO 9001 Certified
⚡
EMC Compliant
🎯 Engineering Support Available: Our machinery protection specialists provide complimentary system design assistance including module selection, power budget calculations, panel layout optimization, and configuration file development. Contact us for pre-purchase consultation or post-installation commissioning support.