Skip to product information
1 of 2

Bently Nevada 330854-080-24-CN Extension Cable | 3300 XL 25mm 8m

Bently Nevada 330854-080-24-CN Extension Cable | 3300 XL 25mm 8m

  • Manufacturer: Bently Nevada

  • Product No.: 330854-080-24-CN

  • Condition:1000 in stock

  • Product Type: Proximity Sensor Cable

  • Product Origin: 330854-080-24-CN

  • Payment: T/T, Western Union

  • Weight: 140g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

⚡ High-Performance Extension Cable for Precision Vibration Sensing

The Bently Nevada 330854-080-24-CN represents the gold standard in proximity probe extension cables, specifically engineered for the 3300 XL 25mm sensor system. This 8-meter (26.2 feet) high-temperature FluidLoc cable extends your monitoring reach in the most demanding industrial environments where standard cables fail.

🎯 Why This Cable Matters for Your Operation

Temperature Extremes: Operating range from -35°C to +200°C (-31°F to +392°F) ensures reliable signal transmission in cryogenic pumps, steam turbines, and furnace-adjacent machinery where conventional cables degrade.

Signal Integrity: Precision-controlled 75Ω triaxial construction with 69.9 pF/m capacitance maintains measurement accuracy within ±0.92mm (±36 mils) across the full temperature spectrum—critical for detecting early bearing faults.

Fluid Resistance: FluidLoc technology prevents oil, coolant, and process fluid migration along the cable core, eliminating false alarms caused by contamination-induced impedance changes.

🔬 Engineering Specifications

Cable Configuration: 330854-AAA-BB-CC

Code Position This Model Available Options
AAA - Length 080 = 8.0 meters (26.2 ft) 040 = 4.0m (13.1 ft) | 080 = 8.0m (26.2 ft)
BB - Cable Type 24 = High-Temp FluidLoc 24 = Standard | 25 = Armored
CC - Certifications CN = China Approvals 00 = None | 05 = Multi-Agency

Electrical Performance Metrics

DC Resistance (Core) 2.0 ± 0.5 ohms @ 8m length
DC Resistance (Jacket) 0.6 ± 0.2 ohms @ 8m length
Capacitance 69.9 pF/m (21.3 pF/ft) typical
Impedance 75 Ω triaxial (precision matched)
Temperature Stability DSL drift ≤ ±0.92mm over full range

Physical Construction

Insulation Material Perfluoroalkoxyethylene (PFA) - chemically inert
Cable Architecture 75Ω triaxial with FluidLoc barrier
Mass per Meter 140 g/m (1.5 oz/ft)
Operating Temp -35°C to +200°C continuous
Storage Temp -35°C to +200°C

🏭 Real-World Application Scenarios

Steam Turbine Monitoring: Install between high-temperature bearing housings (+180°C) and control room proximitors. The 8m length allows routing through cable trays away from radiant heat zones while maintaining signal fidelity for critical thrust position measurements.

Compressor Train Protection: Connect 3300 XL probes on multi-stage compressors to centralized monitoring racks. FluidLoc construction prevents process gas condensate from migrating into proximitor housings, eliminating nuisance trips.

Offshore Platform Installations: Bridge the distance between subsea pump probes and topside control systems. PFA insulation resists saltwater corrosion and UV degradation in exposed cable runs.

Petrochemical Reactor Monitoring: Monitor agitator shaft vibration in vessels with ambient temperatures exceeding +150°C. The cable's thermal stability ensures accurate readings during process upsets and emergency shutdowns.

⚙️ Installation & Compatibility Requirements

⚠️ Critical Length Calculation: Total system length = Probe length + Extension cable length. This MUST match your Proximitor Sensor's specified total length. Mismatched lengths cause calibration errors and false alarms.

Example: If using a 330103-00-08-XX probe (8mm length) with this 8m extension, your Proximitor must be configured for 8.008m total system length.

Compatible Proximitor Models:

  • 3300 XL 25mm Proximity Transducer System
  • 3300 XL NSv Proximity Sensor (25mm tip diameter)
  • 3300 XL ETR Reverse Mount Probes (25mm series)

Installation Best Practices:

  • Maintain minimum 50mm (2") bend radius to prevent core damage
  • Route away from high-voltage power cables (>300mm separation)
  • Use cable glands rated for operating temperature range
  • Verify DC resistance after installation to confirm integrity
  • Label both ends with system length for future maintenance

📈 System Performance Validation

Temperature Compensation Testing:

  • Probe at -35°C to +120°C, cable/proximitor at 0°C to +45°C: DSL ≤ ±0.92mm
  • Cable/proximitor at -35°C to +65°C, probe at 0°C to +45°C: DSL ≤ ±0.92mm

This dual-range validation ensures accurate measurements regardless of which component experiences temperature extremes—essential for applications with localized heating or cooling.

🔍 Common Issues & Solutions

Symptom Probable Cause Solution
Erratic readings Fluid ingress in connector Verify FluidLoc seal integrity; replace if compromised
Offset drift Temperature mismatch Confirm total system length matches proximitor setting
High noise EMI coupling Reroute away from VFDs/power cables; check grounding
Open circuit alarm Core break from overbending Inspect for kinks; measure DC resistance

📦 What You Receive

  • 1× Bently Nevada 330854-080-24-CN Extension Cable (8 meters)
  • Pre-installed triaxial connectors (probe-end and proximitor-end)
  • Cable identification label with part number and length
  • Installation guidelines and resistance verification chart

✅ Certifications & Standards Compliance

  • China Compulsory Certification (CCC) - CN designation
  • API 670 Machinery Protection Systems (compatible)
  • ISO 20816 Vibration Measurement Standards
  • RoHS compliant materials

🔄 System Expansion Options

When upgrading from 3300 NSv to 3300 XL systems, this extension cable integrates seamlessly with existing proximitor infrastructure. The 25mm probe diameter provides enhanced sensitivity for detecting sub-micron shaft movements in high-speed turbomachinery.

Need assistance with system length calculations or compatibility verification? Our vibration monitoring specialists provide free pre-installation support to ensure optimal system performance.

View full details

Product Description

⚡ High-Performance Extension Cable for Precision Vibration Sensing

The Bently Nevada 330854-080-24-CN represents the gold standard in proximity probe extension cables, specifically engineered for the 3300 XL 25mm sensor system. This 8-meter (26.2 feet) high-temperature FluidLoc cable extends your monitoring reach in the most demanding industrial environments where standard cables fail.

🎯 Why This Cable Matters for Your Operation

Temperature Extremes: Operating range from -35°C to +200°C (-31°F to +392°F) ensures reliable signal transmission in cryogenic pumps, steam turbines, and furnace-adjacent machinery where conventional cables degrade.

Signal Integrity: Precision-controlled 75Ω triaxial construction with 69.9 pF/m capacitance maintains measurement accuracy within ±0.92mm (±36 mils) across the full temperature spectrum—critical for detecting early bearing faults.

Fluid Resistance: FluidLoc technology prevents oil, coolant, and process fluid migration along the cable core, eliminating false alarms caused by contamination-induced impedance changes.

🔬 Engineering Specifications

Cable Configuration: 330854-AAA-BB-CC

Code Position This Model Available Options
AAA - Length 080 = 8.0 meters (26.2 ft) 040 = 4.0m (13.1 ft) | 080 = 8.0m (26.2 ft)
BB - Cable Type 24 = High-Temp FluidLoc 24 = Standard | 25 = Armored
CC - Certifications CN = China Approvals 00 = None | 05 = Multi-Agency

Electrical Performance Metrics

DC Resistance (Core) 2.0 ± 0.5 ohms @ 8m length
DC Resistance (Jacket) 0.6 ± 0.2 ohms @ 8m length
Capacitance 69.9 pF/m (21.3 pF/ft) typical
Impedance 75 Ω triaxial (precision matched)
Temperature Stability DSL drift ≤ ±0.92mm over full range

Physical Construction

Insulation Material Perfluoroalkoxyethylene (PFA) - chemically inert
Cable Architecture 75Ω triaxial with FluidLoc barrier
Mass per Meter 140 g/m (1.5 oz/ft)
Operating Temp -35°C to +200°C continuous
Storage Temp -35°C to +200°C

🏭 Real-World Application Scenarios

Steam Turbine Monitoring: Install between high-temperature bearing housings (+180°C) and control room proximitors. The 8m length allows routing through cable trays away from radiant heat zones while maintaining signal fidelity for critical thrust position measurements.

Compressor Train Protection: Connect 3300 XL probes on multi-stage compressors to centralized monitoring racks. FluidLoc construction prevents process gas condensate from migrating into proximitor housings, eliminating nuisance trips.

Offshore Platform Installations: Bridge the distance between subsea pump probes and topside control systems. PFA insulation resists saltwater corrosion and UV degradation in exposed cable runs.

Petrochemical Reactor Monitoring: Monitor agitator shaft vibration in vessels with ambient temperatures exceeding +150°C. The cable's thermal stability ensures accurate readings during process upsets and emergency shutdowns.

⚙️ Installation & Compatibility Requirements

⚠️ Critical Length Calculation: Total system length = Probe length + Extension cable length. This MUST match your Proximitor Sensor's specified total length. Mismatched lengths cause calibration errors and false alarms.

Example: If using a 330103-00-08-XX probe (8mm length) with this 8m extension, your Proximitor must be configured for 8.008m total system length.

Compatible Proximitor Models:

  • 3300 XL 25mm Proximity Transducer System
  • 3300 XL NSv Proximity Sensor (25mm tip diameter)
  • 3300 XL ETR Reverse Mount Probes (25mm series)

Installation Best Practices:

  • Maintain minimum 50mm (2") bend radius to prevent core damage
  • Route away from high-voltage power cables (>300mm separation)
  • Use cable glands rated for operating temperature range
  • Verify DC resistance after installation to confirm integrity
  • Label both ends with system length for future maintenance

📈 System Performance Validation

Temperature Compensation Testing:

  • Probe at -35°C to +120°C, cable/proximitor at 0°C to +45°C: DSL ≤ ±0.92mm
  • Cable/proximitor at -35°C to +65°C, probe at 0°C to +45°C: DSL ≤ ±0.92mm

This dual-range validation ensures accurate measurements regardless of which component experiences temperature extremes—essential for applications with localized heating or cooling.

🔍 Common Issues & Solutions

Symptom Probable Cause Solution
Erratic readings Fluid ingress in connector Verify FluidLoc seal integrity; replace if compromised
Offset drift Temperature mismatch Confirm total system length matches proximitor setting
High noise EMI coupling Reroute away from VFDs/power cables; check grounding
Open circuit alarm Core break from overbending Inspect for kinks; measure DC resistance

📦 What You Receive

  • 1× Bently Nevada 330854-080-24-CN Extension Cable (8 meters)
  • Pre-installed triaxial connectors (probe-end and proximitor-end)
  • Cable identification label with part number and length
  • Installation guidelines and resistance verification chart

✅ Certifications & Standards Compliance

  • China Compulsory Certification (CCC) - CN designation
  • API 670 Machinery Protection Systems (compatible)
  • ISO 20816 Vibration Measurement Standards
  • RoHS compliant materials

🔄 System Expansion Options

When upgrading from 3300 NSv to 3300 XL systems, this extension cable integrates seamlessly with existing proximitor infrastructure. The 25mm probe diameter provides enhanced sensitivity for detecting sub-micron shaft movements in high-speed turbomachinery.

Need assistance with system length calculations or compatibility verification? Our vibration monitoring specialists provide free pre-installation support to ensure optimal system performance.

Download PDF file here:

Click to Download PDF