Probe Diameter |
8 mm |
Overall Probe Length |
80 mm (08 in the part number) |
Tip-to-Sensor Clearance |
150 mm (15 in the part number) |
Cable Length |
110 mm (11 in the part number) |
Armor Type |
Armored cable (05 in the part number) |
Temperature Range |
-46°C to +218°C (-51°F to +425°F) with Extended Temperature Range (ETR) option; standard range up to 177°C (350°F) |
Pressure Rating |
Up to 13.79 bar (200 psig) at probe tip |
Sensing Element |
Non-contact, eddy current probe with polyurethane coating and TipLoc molding |
Electrical Connection |
3-wire configuration with ClickLoc gold-plated connectors |
Hazardous Area Certifications |
CSA, ATEX, IECEx approved for use in explosive atmospheres |
Mounting |
Side view or radial vibration monitoring; mounting clamps sold separately |
Dimensions |
Probe: 8 mm diameter x 80 mm length; cable: 110 mm armored |
Standards Compliance |
API 670 compliant for machinery protection systems |
Nominal Probe DC Resistance |
7.59 ± 0.50 Ω (for 1.0 m equivalent length) |
Connector Protection |
Optional connector protectors recommended for environmental protection |
FluidLoc Option |
Available to prevent oil and other liquids from leaking through the cable |