Measurement Capabilities |
Shaft rotative speed, rotative acceleration, zero speed indication |
Output Types |
Proportional voltage or current output on rear terminal strip |
Alert Status |
Supplies Alert status via relay contacts for external annunciator panel |
Power Consumption |
Nominal 2 watts |
Input Signals |
Accepts Keyphasor or proximity probe signals |
Frequency Range |
0 to 20,000 Hz (0 to 1,200,000 rpm) |
Accuracy |
±0.25% of full scale at 25°C |
Recorder Outputs |
User-programmable +4 to +20 mA, 0 to +10 Vdc, or +1 to +5 Vdc |
Operating Temperature |
0°C to +65°C (+32°F to +150°F) |
Storage Temperature |
-40°C to +85°C (-40°F to +185°F) |
Relative Humidity |
Up to 95%, non-condensing |
Full-scale Range Option (A) |
0-10,000 rpm |
Transducer Input Option (B) |
Standard Keyphasor input |
Alarm Relay Option (C) |
Hermetically-sealed |
Agency Approval Option (D) |
ATEX self certification |
Safety Barrier Option (E) |
Internal |
Trip Multiply Option (F) |
2X |