Skip to product information
1 of 1

Bently Nevada 3300/16-03-02-00-00-00-00 I/O Module 16-Channel

Bently Nevada 3300/16-03-02-00-00-00-00 I/O Module 16-Channel

  • Manufacturer: Bently Nevada

  • Product No.: 3300/16-03-02-00-00-00-00

  • Condition:1000 in stock

  • Product Type: I/O Module

  • Payment: T/T, Western Union

  • Weight: 200g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Bently Nevada 3300/16 I/O Module - 16-Channel Interface

Transform your machinery monitoring data into actionable intelligence. The Bently Nevada 3300/16-03-02-00-00-00-00 is a high-density I/O module that bridges proximity monitoring systems with plant-wide control and data acquisition infrastructure.

📊 Technical Specifications

Full Model: 3300/16-03-02-00-00-00-00
Product Family: 3300 Series I/O Interface Modules
Channel Count: 16 analog input channels
Input Type: Buffered proximity transducer signals
Output Type: 4-20 mA isolated current loops
Isolation: Channel-to-channel and channel-to-ground
Accuracy: ±0.25% of full scale
Update Rate: 10 Hz per channel
Power Supply: 24 VDC ±10%
Operating Temp: 0°C to +60°C (32°F to +140°F)
Mounting: DIN rail or panel mount
Dimensions: Standard Eurocard format

🔌 Integration Architecture

DCS/PLC Connectivity: The 4-20 mA outputs interface directly with distributed control systems, programmable logic controllers, and SCADA platforms—no custom programming required.

Multi-Point Monitoring: Sixteen channels mean you can monitor an entire machine train (bearings, thrust positions, differential expansion) through a single module, reducing hardware costs and simplifying wiring.

Signal Buffering: Inputs buffer proximitor signals without loading the measurement circuit, allowing simultaneous connection to protection systems and data historians without signal degradation.

⚡ Real-World Benefits

Centralized Monitoring: Consolidate vibration data from multiple machines into your existing control room displays
Alarm Integration: Trigger plant-wide alarms and automated responses based on machinery condition
Trend Analysis: Feed continuous data to historians for long-term performance tracking and predictive analytics
Reduced Wiring: High channel density cuts installation time and cable costs by 60% vs single-channel modules
Hot-Swappable: Replace modules without shutting down the entire monitoring system

🏭 Deployment Scenarios

Power Plants: Monitor turbine-generator sets with 8-12 proximity probes per unit, feeding vibration and position data to plant DCS for operator awareness and automated trip logic.

Refineries: Track critical compressor trains across multiple process units, integrating machinery health into overall plant optimization strategies.

Manufacturing: Connect production line machinery to factory MES systems, enabling condition-based maintenance scheduling that minimizes unplanned downtime.

🛠️ Configuration Flexibility

Each channel can be independently configured for different signal ranges and engineering units. Built-in diagnostics detect open circuits, short circuits, and out-of-range conditions, reporting faults via dedicated status outputs. LED indicators provide instant visual confirmation of channel health and communication status.

📋 Compliance & Standards

Meets API 670 requirements for machinery protection systems, CE marked for European installations, and UL/CSA listed for North American facilities. RoHS compliant and backed by ISO 9001 manufacturing quality systems.

Product Status: Brand new, factory-sealed with full manufacturer warranty and technical documentation.

View full details

Product Description

Bently Nevada 3300/16 I/O Module - 16-Channel Interface

Transform your machinery monitoring data into actionable intelligence. The Bently Nevada 3300/16-03-02-00-00-00-00 is a high-density I/O module that bridges proximity monitoring systems with plant-wide control and data acquisition infrastructure.

📊 Technical Specifications

Full Model: 3300/16-03-02-00-00-00-00
Product Family: 3300 Series I/O Interface Modules
Channel Count: 16 analog input channels
Input Type: Buffered proximity transducer signals
Output Type: 4-20 mA isolated current loops
Isolation: Channel-to-channel and channel-to-ground
Accuracy: ±0.25% of full scale
Update Rate: 10 Hz per channel
Power Supply: 24 VDC ±10%
Operating Temp: 0°C to +60°C (32°F to +140°F)
Mounting: DIN rail or panel mount
Dimensions: Standard Eurocard format

🔌 Integration Architecture

DCS/PLC Connectivity: The 4-20 mA outputs interface directly with distributed control systems, programmable logic controllers, and SCADA platforms—no custom programming required.

Multi-Point Monitoring: Sixteen channels mean you can monitor an entire machine train (bearings, thrust positions, differential expansion) through a single module, reducing hardware costs and simplifying wiring.

Signal Buffering: Inputs buffer proximitor signals without loading the measurement circuit, allowing simultaneous connection to protection systems and data historians without signal degradation.

⚡ Real-World Benefits

Centralized Monitoring: Consolidate vibration data from multiple machines into your existing control room displays
Alarm Integration: Trigger plant-wide alarms and automated responses based on machinery condition
Trend Analysis: Feed continuous data to historians for long-term performance tracking and predictive analytics
Reduced Wiring: High channel density cuts installation time and cable costs by 60% vs single-channel modules
Hot-Swappable: Replace modules without shutting down the entire monitoring system

🏭 Deployment Scenarios

Power Plants: Monitor turbine-generator sets with 8-12 proximity probes per unit, feeding vibration and position data to plant DCS for operator awareness and automated trip logic.

Refineries: Track critical compressor trains across multiple process units, integrating machinery health into overall plant optimization strategies.

Manufacturing: Connect production line machinery to factory MES systems, enabling condition-based maintenance scheduling that minimizes unplanned downtime.

🛠️ Configuration Flexibility

Each channel can be independently configured for different signal ranges and engineering units. Built-in diagnostics detect open circuits, short circuits, and out-of-range conditions, reporting faults via dedicated status outputs. LED indicators provide instant visual confirmation of channel health and communication status.

📋 Compliance & Standards

Meets API 670 requirements for machinery protection systems, CE marked for European installations, and UL/CSA listed for North American facilities. RoHS compliant and backed by ISO 9001 manufacturing quality systems.

Product Status: Brand new, factory-sealed with full manufacturer warranty and technical documentation.