Skip to product information
1 of 2

Bently Nevada 16710-10 Armored Interconnect Cable | 10ft 22AWG

Bently Nevada 16710-10 Armored Interconnect Cable | 10ft 22AWG

  • Manufacturer: Bently Nevada

  • Product No.: 16710-10

  • Condition:1000 in stock

  • Product Type: Industrial Interconnect Cable

  • Product Origin: 16710-10

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

⚡ Industrial-Grade Armored Interconnect Cable for Critical Monitoring Applications

The Bently Nevada 16710-10 represents precision-engineered connectivity for demanding industrial environments. This 10-foot armored interconnect cable delivers reliable signal transmission between monitoring modules, relay panels, and control interfaces in vibration monitoring and machinery protection systems. Built with triple-layer protection—conductor shielding, armor jacketing, and interference rejection—it ensures signal integrity in electrically noisy plant environments.

🔌 Engineering Features & Construction Quality

  • Triple-Shielded Architecture: 22 AWG (0.5 mm²) conductors with individual shielding, collective screen, and armored outer jacket
  • Hybrid Termination Design: 3-socket industrial plug (one end) + screw terminal lugs (other end) for versatile installation
  • Integrated Relay Circuits: 2 volt-free Normally Open (NO) contacts rated for alarm and interlock applications
  • Solid-State Output Channels: 2 additional low-voltage outputs for PLC/DCS interface compatibility
  • Factory-Calibrated Length: Precision 10-foot (3.0 m) span indicated by "-10" suffix—ideal for rack-to-panel distances

📐 Detailed Technical Specifications

Specification Value
Part Number 16710-10
Cable Length 10 ft (3.0 m) ±2%
Conductor Specification 3-conductor, 22 AWG (0.5 mm²)
Shielding Type Braided copper shield + aluminum foil wrap
Armor Construction Galvanized steel interlocked armor
End A Connector 3-socket industrial plug (Bently Nevada proprietary)
End B Termination Compression terminal lugs (M4 screw size)
Relay Configuration 2× NO (Normally Open) volt-free contacts
Relay Contact Rating 5A @ 250VAC / 30VDC resistive load
Solid-State Outputs 2× channels, 24VDC logic compatible
Voltage Rating 300V AC/DC maximum
Temperature Range -40°C to +85°C (-40°F to +185°F)
Bend Radius (Min) 10× cable diameter (dynamic installation)
Compliance Standards UL 1277, CSA C22.2, IEC 60227

🏗️ Industrial Application Scenarios

Turbine Monitoring Systems: Connect 3500 Series monitor modules to remote alarm panels in power generation facilities, providing both relay contact closure for annunciator boards and solid-state signals for DCS trending.

Compressor Protection Networks: Link proximity probe monitors to emergency shutdown (ESD) systems in gas compression stations, where armored construction protects against mechanical damage in congested pipe racks.

Pump Station Installations: Interface vibration monitors with SCADA RTUs in water/wastewater facilities, utilizing dual output types to simultaneously drive local alarms and transmit status to central control rooms.

Refinery Process Units: Establish hardened connections between machinery monitors and safety instrumented systems (SIS) in classified hazardous areas, meeting area classification wiring requirements.

💼 Installation Advantages & System Integration

  • Plug-and-Play Compatibility: Pre-wired socket connector eliminates field termination errors on monitor side
  • Flexible Field Wiring: Terminal lug end allows custom connections to diverse control equipment
  • EMI/RFI Immunity: Multi-layer shielding maintains signal quality near VFDs, welders, and RF transmitters
  • Mechanical Durability: Armor jacket withstands cable tray abrasion, foot traffic, and incidental impact
  • Standardized Length: 10-foot span matches typical rack-to-marshalling-cabinet distances, minimizing excess cable loops

🔧 Ordering & Configuration Information

Standard Model: 16710-10 (this product) provides the most common 10-foot length with full relay and solid-state output complement.

Custom Length Options: The 16710 series supports custom lengths from 3 ft (0.9 m) to 99 ft (30 m) via special order. Contact technical sales for extended-length configurations or alternate relay arrangements.

Part Number Decoding:

  • 16710 = Base model (armored interconnect cable with hybrid outputs)
  • -10 = 10-foot length with 2 NO relay circuits + 2 solid-state outputs

🔗 System Compatibility & Typical Pairings

3500/42 Proximitor Monitor Relay outputs for high-vibration alarms to annunciator panels
3500/50 Tachometer Module Speed deviation signals to turbine control systems
2300/20 Vibration Monitor 4-20mA loop isolation and relay contact backup
3500/92 Communication Gateway Discrete I/O expansion for alarm status distribution
3500/20 RIM I/O Module Direct rack-to-relay interface module connections

📦 Package Contents & Delivery

  • 1× Bently Nevada 16710-10 armored interconnect cable (10 ft)
  • Pre-installed 3-socket connector (End A)
  • Pre-stripped and tinned terminal lugs (End B)
  • Cable identification label with part number
  • Installation guide and wiring diagram

✅ Quality & Support

Every 16710-10 cable undergoes factory continuity testing, insulation resistance verification (500VDC megger test), and shield integrity validation. Backed by comprehensive technical documentation and application engineering support for complex installations.

🛠️ Installation Best Practices

  • Route cable through dedicated instrumentation trays separate from power conductors
  • Maintain minimum 12-inch separation from AC power cables >600V
  • Ground armor jacket at one end only to prevent ground loops
  • Use cable ties at 18-inch intervals; avoid over-tightening on armored jacket
  • Label both ends with source/destination for future troubleshooting

For custom cable lengths, special relay configurations, or application-specific wiring guidance, consult with our industrial connectivity specialists.

View full details

Product Description

⚡ Industrial-Grade Armored Interconnect Cable for Critical Monitoring Applications

The Bently Nevada 16710-10 represents precision-engineered connectivity for demanding industrial environments. This 10-foot armored interconnect cable delivers reliable signal transmission between monitoring modules, relay panels, and control interfaces in vibration monitoring and machinery protection systems. Built with triple-layer protection—conductor shielding, armor jacketing, and interference rejection—it ensures signal integrity in electrically noisy plant environments.

🔌 Engineering Features & Construction Quality

  • Triple-Shielded Architecture: 22 AWG (0.5 mm²) conductors with individual shielding, collective screen, and armored outer jacket
  • Hybrid Termination Design: 3-socket industrial plug (one end) + screw terminal lugs (other end) for versatile installation
  • Integrated Relay Circuits: 2 volt-free Normally Open (NO) contacts rated for alarm and interlock applications
  • Solid-State Output Channels: 2 additional low-voltage outputs for PLC/DCS interface compatibility
  • Factory-Calibrated Length: Precision 10-foot (3.0 m) span indicated by "-10" suffix—ideal for rack-to-panel distances

📐 Detailed Technical Specifications

Specification Value
Part Number 16710-10
Cable Length 10 ft (3.0 m) ±2%
Conductor Specification 3-conductor, 22 AWG (0.5 mm²)
Shielding Type Braided copper shield + aluminum foil wrap
Armor Construction Galvanized steel interlocked armor
End A Connector 3-socket industrial plug (Bently Nevada proprietary)
End B Termination Compression terminal lugs (M4 screw size)
Relay Configuration 2× NO (Normally Open) volt-free contacts
Relay Contact Rating 5A @ 250VAC / 30VDC resistive load
Solid-State Outputs 2× channels, 24VDC logic compatible
Voltage Rating 300V AC/DC maximum
Temperature Range -40°C to +85°C (-40°F to +185°F)
Bend Radius (Min) 10× cable diameter (dynamic installation)
Compliance Standards UL 1277, CSA C22.2, IEC 60227

🏗️ Industrial Application Scenarios

Turbine Monitoring Systems: Connect 3500 Series monitor modules to remote alarm panels in power generation facilities, providing both relay contact closure for annunciator boards and solid-state signals for DCS trending.

Compressor Protection Networks: Link proximity probe monitors to emergency shutdown (ESD) systems in gas compression stations, where armored construction protects against mechanical damage in congested pipe racks.

Pump Station Installations: Interface vibration monitors with SCADA RTUs in water/wastewater facilities, utilizing dual output types to simultaneously drive local alarms and transmit status to central control rooms.

Refinery Process Units: Establish hardened connections between machinery monitors and safety instrumented systems (SIS) in classified hazardous areas, meeting area classification wiring requirements.

💼 Installation Advantages & System Integration

  • Plug-and-Play Compatibility: Pre-wired socket connector eliminates field termination errors on monitor side
  • Flexible Field Wiring: Terminal lug end allows custom connections to diverse control equipment
  • EMI/RFI Immunity: Multi-layer shielding maintains signal quality near VFDs, welders, and RF transmitters
  • Mechanical Durability: Armor jacket withstands cable tray abrasion, foot traffic, and incidental impact
  • Standardized Length: 10-foot span matches typical rack-to-marshalling-cabinet distances, minimizing excess cable loops

🔧 Ordering & Configuration Information

Standard Model: 16710-10 (this product) provides the most common 10-foot length with full relay and solid-state output complement.

Custom Length Options: The 16710 series supports custom lengths from 3 ft (0.9 m) to 99 ft (30 m) via special order. Contact technical sales for extended-length configurations or alternate relay arrangements.

Part Number Decoding:

  • 16710 = Base model (armored interconnect cable with hybrid outputs)
  • -10 = 10-foot length with 2 NO relay circuits + 2 solid-state outputs

🔗 System Compatibility & Typical Pairings

3500/42 Proximitor Monitor Relay outputs for high-vibration alarms to annunciator panels
3500/50 Tachometer Module Speed deviation signals to turbine control systems
2300/20 Vibration Monitor 4-20mA loop isolation and relay contact backup
3500/92 Communication Gateway Discrete I/O expansion for alarm status distribution
3500/20 RIM I/O Module Direct rack-to-relay interface module connections

📦 Package Contents & Delivery

  • 1× Bently Nevada 16710-10 armored interconnect cable (10 ft)
  • Pre-installed 3-socket connector (End A)
  • Pre-stripped and tinned terminal lugs (End B)
  • Cable identification label with part number
  • Installation guide and wiring diagram

✅ Quality & Support

Every 16710-10 cable undergoes factory continuity testing, insulation resistance verification (500VDC megger test), and shield integrity validation. Backed by comprehensive technical documentation and application engineering support for complex installations.

🛠️ Installation Best Practices

  • Route cable through dedicated instrumentation trays separate from power conductors
  • Maintain minimum 12-inch separation from AC power cables >600V
  • Ground armor jacket at one end only to prevent ground loops
  • Use cable ties at 18-inch intervals; avoid over-tightening on armored jacket
  • Label both ends with source/destination for future troubleshooting

For custom cable lengths, special relay configurations, or application-specific wiring guidance, consult with our industrial connectivity specialists.