Skip to product information
1 of 7

ALLEN BRADLEY 1756-CFM/A ControlLogix Configurable Flowmeter Module

ALLEN BRADLEY 1756-CFM/A ControlLogix Configurable Flowmeter Module

  • Manufacturer: ALLEN BRADLEY

  • Product No.: 1756-CFM/A

  • Condition:1000 in stock

  • Product Type: ControlLogix Configurable Flowmeter Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Overview

Parameter Details
Part Number 1756-CFM, Series A
Product Name ControlLogix Configurable Flowmeter Module
Application High-speed flowmetering for industrial automation
Compatibility Compatible with ControlLogix chassis, supports ControlNet and EtherNet/IP networks
Function Processes signals from flowmeters for precise flow measurement and control

Functional Specifications

Parameter Details
Input Channels 4 flowmeter inputs (2 per channel, single-ended or differential)
Input Types Magnetic pickup, preamplified pulse, or dry contact
Input Voltage Range 50 mV to 30 V peak-to-peak (magnetic pickup), 5–30 V DC (pulse or dry contact)
Input Frequency Range 0.2 Hz to 20 kHz
Input Impedance 10 kΩ (magnetic pickup), 3 kΩ (pulse or dry contact)
Output Channels 2 digital outputs per channel (4 total)
Output Type Solid-state, sourcing
Output Voltage Range 10–30 V DC
Output Current 0.5 A per output, 2 A total per module
On-State Voltage Drop 1.0 V maximum
Off-State Leakage Current 50 µA maximum
Signal Delay Time 1 ms (input to output)
Power Dissipation 6.5 W maximum
Backplane Current Load 300 mA @ 5.1 V DC, 3 mA @ 24 V DC
Isolation 250 V AC (between inputs and backplane), 1500 V AC (between outputs and backplane)
Terminal Connections 36-pin removable terminal block (RTB), 1756-TBCH or 1756-TBS6H
Wire Size 0.2–2.5 mm² (22–14 AWG)
Operating Temperature 0°C to 60°C (32°F to 140°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Humidity 5% to 95% (non-condensing)
Vibration Tolerance 2 G @ 10–500 Hz
Shock Tolerance 30 G (operating), 50 G (non-operating)
Dimensions 145 mm x 35 mm x 140 mm (5.71 in x 1.38 in x 5.51 in)
Weight 0.4 kg (0.88 lb)
Standards Compliance CE, UL, CSA (Class I, Div 2, Groups A, B, C, D), FM
Certifications TUV certified for functional safety (SIL 2)


View full details

Product Description

Product Overview

Parameter Details
Part Number 1756-CFM, Series A
Product Name ControlLogix Configurable Flowmeter Module
Application High-speed flowmetering for industrial automation
Compatibility Compatible with ControlLogix chassis, supports ControlNet and EtherNet/IP networks
Function Processes signals from flowmeters for precise flow measurement and control

Functional Specifications

Parameter Details
Input Channels 4 flowmeter inputs (2 per channel, single-ended or differential)
Input Types Magnetic pickup, preamplified pulse, or dry contact
Input Voltage Range 50 mV to 30 V peak-to-peak (magnetic pickup), 5–30 V DC (pulse or dry contact)
Input Frequency Range 0.2 Hz to 20 kHz
Input Impedance 10 kΩ (magnetic pickup), 3 kΩ (pulse or dry contact)
Output Channels 2 digital outputs per channel (4 total)
Output Type Solid-state, sourcing
Output Voltage Range 10–30 V DC
Output Current 0.5 A per output, 2 A total per module
On-State Voltage Drop 1.0 V maximum
Off-State Leakage Current 50 µA maximum
Signal Delay Time 1 ms (input to output)
Power Dissipation 6.5 W maximum
Backplane Current Load 300 mA @ 5.1 V DC, 3 mA @ 24 V DC
Isolation 250 V AC (between inputs and backplane), 1500 V AC (between outputs and backplane)
Terminal Connections 36-pin removable terminal block (RTB), 1756-TBCH or 1756-TBS6H
Wire Size 0.2–2.5 mm² (22–14 AWG)
Operating Temperature 0°C to 60°C (32°F to 140°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Humidity 5% to 95% (non-condensing)
Vibration Tolerance 2 G @ 10–500 Hz
Shock Tolerance 30 G (operating), 50 G (non-operating)
Dimensions 145 mm x 35 mm x 140 mm (5.71 in x 1.38 in x 5.51 in)
Weight 0.4 kg (0.88 lb)
Standards Compliance CE, UL, CSA (Class I, Div 2, Groups A, B, C, D), FM
Certifications TUV certified for functional safety (SIL 2)


Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%