Skip to product information
1 of 2

ABB 1MRK002246-BD Transformer Protection Relay Module

ABB 1MRK002246-BD Transformer Protection Relay Module

  • Manufacturer: ABB

  • Product No.: 1MRK002246-BD

  • Condition:1000 in stock

  • Product Type: Transformer Protection Relay

  • Product Origin: 1002246000013

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

ABB 1MRK002246-BD Transformer Protection Relay Module - Comprehensive Power Transformer Protection

The ABB 1MRK002246-BD Transformer Protection Relay Module represents advanced protection technology for power transformers in utility substations, industrial power distribution systems, and renewable energy installations. Engineered with multi-function protection algorithms and integrated monitoring capabilities, this relay provides comprehensive fault detection including differential protection, overcurrent protection, restricted earth fault (REF) protection, and thermal overload monitoring to safeguard critical transformer assets valued in millions of dollars.

Core Technical Specifications

  • Protection Functions: Differential, overcurrent, earth fault, REF, thermal overload
  • Voltage Inputs: 3-phase voltage measurement, 57.7-240V AC nominal
  • Current Inputs: 6 CT inputs for differential and backup protection
  • CT Rating: 1A or 5A selectable, burden <0.1VA per input
  • Operating Range: 10-400% of rated current
  • Differential Sensitivity: 5-50% adjustable pickup threshold
  • Operating Time: <20ms for internal faults at 2x pickup
  • Communication Protocols: IEC 61850, Modbus RTU/TCP, DNP3
  • Digital Inputs: 16 programmable binary inputs for external signals
  • Output Relays: 12 configurable trip/alarm contacts rated 250VAC/8A
  • Display: Backlit LCD with event recording and waveform capture
  • Operating Temperature: -40°C to +70°C extended industrial range
  • Power Supply: 24-250VDC/110-240VAC universal input

Advanced Protection Algorithms

The 1MRK002246-BD incorporates sophisticated protection logic that distinguishes between internal transformer faults requiring immediate isolation and external system disturbances that should be tolerated:

  • Percentage Differential Protection: Biased differential algorithm with harmonic restraint detects internal winding faults, core faults, and bushing failures while remaining stable during external faults and inrush conditions
  • Harmonic Blocking: Second and fifth harmonic detection prevents false tripping during transformer energization when magnetizing inrush currents can exceed 10x rated current
  • Restricted Earth Fault (REF): High-sensitivity ground fault detection for winding-to-ground faults in resistance-grounded systems with pickup settings as low as 5% of rated current
  • Thermal Overload Protection: Thermal replica model calculates winding hot-spot temperature based on load current and ambient conditions, preventing insulation degradation from sustained overloads
  • Overcurrent Backup: Time-delayed overcurrent elements provide backup protection for differential zone failures and coordination with downstream protective devices
  • Breaker Failure Protection: Initiates remote tripping if local circuit breaker fails to clear fault within programmable time delay

Industrial Application Solutions

This transformer protection relay addresses critical asset protection requirements across diverse power system applications where transformer failures result in extended outages and catastrophic equipment damage:

  • Utility Substation Transformers: Protects transmission-to-distribution step-down transformers (69kV/13.8kV typical) serving thousands of customers, preventing cascading outages from internal faults
  • Industrial Plant Distribution: Safeguards medium-voltage transformers in petrochemical facilities, steel mills, and manufacturing plants where process continuity depends on reliable power delivery
  • Renewable Energy Integration: Monitors step-up transformers at wind farms and solar installations, coordinating with grid protection schemes during fault ride-through events
  • Data Center Power Systems: Provides redundant protection for mission-critical UPS isolation transformers and generator step-up transformers in Tier III/IV facilities
  • Mining Operations: Protects underground substation transformers in harsh environments with high fault currents and limited access for maintenance
  • Marine and Offshore Platforms: Monitors shipboard and offshore platform transformers subject to vibration, humidity, and corrosive atmospheres
  • Railway Traction Substations: Coordinates protection for AC/DC converter transformers in electrified rail systems with regenerative braking loads

System Integration Architecture

The 1MRK002246-BD functions as an intelligent electronic device (IED) within substation automation systems, communicating with SCADA masters, bay controllers, and peer relays via IEC 61850 GOOSE messaging for high-speed interlocking. The relay publishes real-time measurements, protection status, and event records to substation HMI systems, enabling centralized monitoring and analysis. Integration with synchrophasor measurement units (PMUs) supports wide-area protection schemes and post-fault disturbance analysis.

Engineering Design Excellence

  • Self-Monitoring Diagnostics: Continuous supervision of CT circuits, voltage inputs, trip coil continuity, and internal electronics with automatic alarm generation for degraded conditions
  • Disturbance Recording: High-resolution waveform capture (16 samples/cycle) with pre-fault and post-fault buffering for detailed fault analysis and protection performance validation
  • Adaptive Protection: Automatic adjustment of differential slope characteristics based on transformer tap position and loading conditions
  • Cybersecurity Features: Role-based access control, encrypted communications, and audit logging compliant with NERC CIP standards for critical infrastructure protection
  • Redundant Architecture: Dual power supply inputs and watchdog timers ensure relay availability exceeds 99.99% for mission-critical applications
  • Flexible Configuration: Programmable logic equations enable custom protection schemes, automatic transfer schemes, and load shedding sequences

Installation & Commissioning

The relay mounts in standard 19-inch substation control panels with rear-access terminal blocks for CT, VT, and control wiring. Installation involves CT polarity verification, voltage phasing checks, and protection setting calculations based on transformer nameplate data and system fault studies. Commissioning includes primary and secondary injection testing to verify differential element operation, harmonic restraint performance, and trip circuit integrity—typically requiring 4-6 hours by qualified protection engineers.

Quality Standards & Compliance

Manufactured in Switzerland under ISO 9001:2015 quality management systems with type testing per IEC 60255 protective relay standards. Complies with IEEE C37.91 for surge withstand capability, IEC 61000 for electromagnetic compatibility, and IEC 61850 for substation communication protocols. Suitable for installation in harsh industrial environments meeting IEC 60068 environmental testing specifications. NERC CIP cybersecurity compliant for bulk electric system applications.

Related Products for Complete Substation Protection

Product Model Primary Function Product Link
ABB REJ603BBB10NN3XC Generator and motor protection relay with stator ground fault detection View Product
ABB REU615 Voltage protection relay for overvoltage and undervoltage monitoring View Product
ABB REB670 Busbar protection relay with high-impedance differential protection View Product

Why Choose Industrial Control Hub?

We specialize in delivering factory-certified authentic ABB protection relays with comprehensive technical documentation, protection engineering support, and expedited global logistics. Our power systems specialists provide pre-sale consultation including protection coordination studies, relay setting calculations, and IEC 61850 configuration services for your specific substation requirements. Post-sale support includes commissioning assistance, firmware updates, and lifecycle maintenance planning to maximize transformer asset protection and system reliability.

Product Authenticity: Factory-certified genuine ABB components with serialized traceability and anti-counterfeit verification
Technical Expertise: Certified protection engineers for relay coordination studies and commissioning support
Express Logistics: Priority shipping to critical utility and industrial facilities with customs documentation
Warranty Coverage: Comprehensive manufacturer-backed warranty with extended protection options
Documentation Suite: Complete technical manuals, setting calculation tools, IEC 61850 configuration files, and test reports


© 2025 INDUSTRIAL CONTROL HUB. All rights reserved.
Original Source: https://www.indctrlhub.com
Contact: sales@indctrlhub.com | +0086 18359243191

View full details

Product Description

ABB 1MRK002246-BD Transformer Protection Relay Module - Comprehensive Power Transformer Protection

The ABB 1MRK002246-BD Transformer Protection Relay Module represents advanced protection technology for power transformers in utility substations, industrial power distribution systems, and renewable energy installations. Engineered with multi-function protection algorithms and integrated monitoring capabilities, this relay provides comprehensive fault detection including differential protection, overcurrent protection, restricted earth fault (REF) protection, and thermal overload monitoring to safeguard critical transformer assets valued in millions of dollars.

Core Technical Specifications

  • Protection Functions: Differential, overcurrent, earth fault, REF, thermal overload
  • Voltage Inputs: 3-phase voltage measurement, 57.7-240V AC nominal
  • Current Inputs: 6 CT inputs for differential and backup protection
  • CT Rating: 1A or 5A selectable, burden <0.1VA per input
  • Operating Range: 10-400% of rated current
  • Differential Sensitivity: 5-50% adjustable pickup threshold
  • Operating Time: <20ms for internal faults at 2x pickup
  • Communication Protocols: IEC 61850, Modbus RTU/TCP, DNP3
  • Digital Inputs: 16 programmable binary inputs for external signals
  • Output Relays: 12 configurable trip/alarm contacts rated 250VAC/8A
  • Display: Backlit LCD with event recording and waveform capture
  • Operating Temperature: -40°C to +70°C extended industrial range
  • Power Supply: 24-250VDC/110-240VAC universal input

Advanced Protection Algorithms

The 1MRK002246-BD incorporates sophisticated protection logic that distinguishes between internal transformer faults requiring immediate isolation and external system disturbances that should be tolerated:

  • Percentage Differential Protection: Biased differential algorithm with harmonic restraint detects internal winding faults, core faults, and bushing failures while remaining stable during external faults and inrush conditions
  • Harmonic Blocking: Second and fifth harmonic detection prevents false tripping during transformer energization when magnetizing inrush currents can exceed 10x rated current
  • Restricted Earth Fault (REF): High-sensitivity ground fault detection for winding-to-ground faults in resistance-grounded systems with pickup settings as low as 5% of rated current
  • Thermal Overload Protection: Thermal replica model calculates winding hot-spot temperature based on load current and ambient conditions, preventing insulation degradation from sustained overloads
  • Overcurrent Backup: Time-delayed overcurrent elements provide backup protection for differential zone failures and coordination with downstream protective devices
  • Breaker Failure Protection: Initiates remote tripping if local circuit breaker fails to clear fault within programmable time delay

Industrial Application Solutions

This transformer protection relay addresses critical asset protection requirements across diverse power system applications where transformer failures result in extended outages and catastrophic equipment damage:

  • Utility Substation Transformers: Protects transmission-to-distribution step-down transformers (69kV/13.8kV typical) serving thousands of customers, preventing cascading outages from internal faults
  • Industrial Plant Distribution: Safeguards medium-voltage transformers in petrochemical facilities, steel mills, and manufacturing plants where process continuity depends on reliable power delivery
  • Renewable Energy Integration: Monitors step-up transformers at wind farms and solar installations, coordinating with grid protection schemes during fault ride-through events
  • Data Center Power Systems: Provides redundant protection for mission-critical UPS isolation transformers and generator step-up transformers in Tier III/IV facilities
  • Mining Operations: Protects underground substation transformers in harsh environments with high fault currents and limited access for maintenance
  • Marine and Offshore Platforms: Monitors shipboard and offshore platform transformers subject to vibration, humidity, and corrosive atmospheres
  • Railway Traction Substations: Coordinates protection for AC/DC converter transformers in electrified rail systems with regenerative braking loads

System Integration Architecture

The 1MRK002246-BD functions as an intelligent electronic device (IED) within substation automation systems, communicating with SCADA masters, bay controllers, and peer relays via IEC 61850 GOOSE messaging for high-speed interlocking. The relay publishes real-time measurements, protection status, and event records to substation HMI systems, enabling centralized monitoring and analysis. Integration with synchrophasor measurement units (PMUs) supports wide-area protection schemes and post-fault disturbance analysis.

Engineering Design Excellence

  • Self-Monitoring Diagnostics: Continuous supervision of CT circuits, voltage inputs, trip coil continuity, and internal electronics with automatic alarm generation for degraded conditions
  • Disturbance Recording: High-resolution waveform capture (16 samples/cycle) with pre-fault and post-fault buffering for detailed fault analysis and protection performance validation
  • Adaptive Protection: Automatic adjustment of differential slope characteristics based on transformer tap position and loading conditions
  • Cybersecurity Features: Role-based access control, encrypted communications, and audit logging compliant with NERC CIP standards for critical infrastructure protection
  • Redundant Architecture: Dual power supply inputs and watchdog timers ensure relay availability exceeds 99.99% for mission-critical applications
  • Flexible Configuration: Programmable logic equations enable custom protection schemes, automatic transfer schemes, and load shedding sequences

Installation & Commissioning

The relay mounts in standard 19-inch substation control panels with rear-access terminal blocks for CT, VT, and control wiring. Installation involves CT polarity verification, voltage phasing checks, and protection setting calculations based on transformer nameplate data and system fault studies. Commissioning includes primary and secondary injection testing to verify differential element operation, harmonic restraint performance, and trip circuit integrity—typically requiring 4-6 hours by qualified protection engineers.

Quality Standards & Compliance

Manufactured in Switzerland under ISO 9001:2015 quality management systems with type testing per IEC 60255 protective relay standards. Complies with IEEE C37.91 for surge withstand capability, IEC 61000 for electromagnetic compatibility, and IEC 61850 for substation communication protocols. Suitable for installation in harsh industrial environments meeting IEC 60068 environmental testing specifications. NERC CIP cybersecurity compliant for bulk electric system applications.

Related Products for Complete Substation Protection

Product Model Primary Function Product Link
ABB REJ603BBB10NN3XC Generator and motor protection relay with stator ground fault detection View Product
ABB REU615 Voltage protection relay for overvoltage and undervoltage monitoring View Product
ABB REB670 Busbar protection relay with high-impedance differential protection View Product

Why Choose Industrial Control Hub?

We specialize in delivering factory-certified authentic ABB protection relays with comprehensive technical documentation, protection engineering support, and expedited global logistics. Our power systems specialists provide pre-sale consultation including protection coordination studies, relay setting calculations, and IEC 61850 configuration services for your specific substation requirements. Post-sale support includes commissioning assistance, firmware updates, and lifecycle maintenance planning to maximize transformer asset protection and system reliability.

Product Authenticity: Factory-certified genuine ABB components with serialized traceability and anti-counterfeit verification
Technical Expertise: Certified protection engineers for relay coordination studies and commissioning support
Express Logistics: Priority shipping to critical utility and industrial facilities with customs documentation
Warranty Coverage: Comprehensive manufacturer-backed warranty with extended protection options
Documentation Suite: Complete technical manuals, setting calculation tools, IEC 61850 configuration files, and test reports


© 2025 INDUSTRIAL CONTROL HUB. All rights reserved.
Original Source: https://www.indctrlhub.com
Contact: sales@indctrlhub.com | +0086 18359243191